CIR11021C
6
GB
mounting. Parallel to the wall/ceiling, 18° or
36° angle.
• Choose the desired angle and fasten the
bracket onto wall or ceiling. The holes are
Ø5 mm, c-c distance is 25 mm.
• Fasten the heaters, snap into the brackets
and secure it by tightening the securing
screws (104 mm long) and the domed nuts
(spanner width 7 mm).
Electrical installation
CIR11021C is equipped with a 1.8 meter
cable and plug, which should be connected
to an earthed wall socket. If permanent
electrical installation, this should be carried
out by a qualified electrician in conformity
with prevailing regulations. The CIR11021C
must be preceded by an all-pole switch.
CIR11021C must not be placed directly under
a wall-outlet. All work must be carried out
with no voltage connected.
Maintenance
The heater is on the whole made of rustproof
material and usually does not require any
maintenance. Pollution can in the long run
dull the reflectors somewhat. This however
has very little affect on its function. If the
heater is very dirty it can be cleaned with
compressed air. If the reflector remains
dirty it must be replaced by an authorized
repairman. The reflector must not be polished
as this may damage the protective surface.
Packaging
Packaging materials are chosen with consi-
deration to environment and are therefore
recyclable.
Handling of product at end of working life
This product may contain substances neces-
sary for functionality of product but poten-
tially dangerous for the environment. The
product should not be disposed mixed with
general household waste but delivered to a
designated collection point for environmental
recycling. Please contact local authority for
further details of your nearest designated col-
lection point.
General recommendations
Read these instructions carefully before
using the appliance for the first time. Keep
these instructions in a safe place for future
reference.
The warranty is only valid if the units
are used in accordance with the Frico
installation and operating instructions.
Area of use
The radiant heaters are primarily used to
create comfortable heating on terraces,
balconies, openair restaurants etc.
Protection class: IP24.
Positioning
The heaters must be placed so that they
enclose the area to be heated, see fig. 1 and 2.
The normal assembly height is 2–2,5 metres
above the ground/floor.
A rule of thumb for infrared heaters
equipped with metal tubular elements is that
750–1000 W/m² increases the experienced
temperature by about 10 °C. The output
demand can be reduced if the area to be
heated is protected. If the area only has a
roof, at least 1000 W/m² should be installed.
750 W/m² is sufficient if the area has three
walls. For enclosed areas, the output demand
must be calculated. A green house for
example requires 250-300 W/m². Optimum
comfort is achieved if the heat is distributed
from at least two directions.
Mounting
Mounting is very easy using the two brackets
(supplied as standard), which can be mounted
on the ceiling or wall in different angles.
When angle mounting CIR11021C on the
ceiling, standard brackets can not be used
(the distance to the ceiling will be smaller
than the minimum distance 150 mm). The
distance between the brackets is adjustable
and can be chosen according to the most
appropriate place for installation. CIR11021C
can also be suspended from wires. For
minimum mounting distance, see Fig. 3.
• CIR11021C may only be mounted
horizontally!
• The mounting brackets enable mounting
in three different angles for ceiling or wall
Mounting and assembly instruction