FS N Series User manual

MANAGED L2/L3 DATA
CENTER SWITCHES
N Series 10G/25G/40G/100G Switches
Quick Start Guide V1.0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Loc
Diag
Fan
PS1
PS2
Reset
MGMT
CONSOLE SFP+
Loc
DIAG
FAN
PS1
PS2
RESET
4
3
1
2
1
4
3
2
124
3
2
144
3
2
164
3
2
184
3
2
110 4
3
2
112 4
3
2
114 4
3
2
116 4
3
2
118 4
3
2
120 4
3
2
122 4
3
2
124 4
3
2
126 4
3
2
128 4
3
2
130 4
3
2
132
4
3
3
2
14
3
5
2
14
3
7
2
14
3
9
2
14
3
11
2
14
3
13
2
14
3
15
2
14
3
17
2
14
3
19
2
14
3
21
2
14
3
23
2
14
3
25
2
14
3
27
2
14
3
29
2
14
3
31
2
1
CONSOLE MGMT
N8050-32Q
N8520-32C
N8550-32C
CONSOLE MGMT
52 53

Introduction
Thank you for choosing N Series 10G/25G/40G/100G Switches. This guide is designed to familiarize
you with the layout of the switch and describes how to deploy the switch in your network.
Accessories
NOTE: The switch includes plug-in power supply (PSU) and fan tray modules that are
installed into its chassis.
Power Cord x2
M4 Screw x20 Ear-locking Screw x2 Holder Bracket x2
Console Cable x1
Front-post Bracket x2
Rear-post Bracket x2
N5850-48S6Q
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
RESETPS1 PS2 DIAG FAN LOC
1 2 3 4
49
1 2 3 4
50
1 2 3 4
51
1 2 3 4
52
1234
54
51 54
1 2 3 4
53
MGMT
CONSOLE
LINK ACT
LOC
DIAG
FAN
PS1
PS2
RESET
43
1
21
4
321 24321 44321 64321 84321 10 4321 12 4321 14 4321 16 4321 18 4321 20 4321 22 4321 24 4321 26 4321 28 4321 30 4321 32
4
3
3
21 43
5
21 43
7
21 43
9
21 43
11
21 43
13
21 43
15
21 43
17
21 43
19
21 43
21
21 43
23
21 43
25
21 43
27
21 43
29
21 43
31
21
CONSOLE MGMT
N8050-32Q
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
MGMT CONSOLE
RESETPS1 PS2 DIAG FAN LOC
1 2 3 4
49
1234
50
1234
51
1234
52
1234
53
1 2 3 4
54
51 54
N8520-48B6C
1 42 3 5 6 7 108 9 11 12 13 1614 15 17 18 19 2220 31 23 24 25 2826 27 29 30 31 3432 33 35 36 37 4038 39 41 42 43 4644 45 47 48
PS1
PS2
FAN
DIAG
LOC
RESET
49 50 51 52 53 54 55 56
49
50
L1 L2 L3 L4
51
52
L1 L2 L3 L4
53
54
L1 L2 L3 L4
55
56
L1 L2 L3 L4
57 58 MGMT CONSOLE
USBCONSOLE
N8550-48B8C
LOC
DIAG
FAN
PS1
PS2
ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
CONSOLE MGMT
RESET LINK/ACTIVITY
N8520-32C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
LOC
DIAG
FAN
PS1
PS2
RESET
MGMT
CONSOLE SFP+
N8550-32C
N5850-48S6Q
N8520-48B6C
N8550-48B8C
N8050-32Q
N8520-32C
N8550-32C

Hardware Overview
Front Panel Ports
N5850-48S6Q
N5850-48S6Q
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
RESETPS1 PS2 DIAG FAN LOC
1 2 3 4
49
1 2 3 4
50
1 2 3 4
51
1 2 3 4
52
1 2 3 4
54
51 54
1 2 3 4
53
MGMT
CONSOLE
LINK ACT
QSFP+SFP+
USB Console
MGMT
QSFP28
N8520-48B6C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
MGMT CONSOLE
RESETPS1 PS2 DIAG FAN LOC
1234
49
1234
50
1234
51
1234
52
1234
53
1234
54
51 54
N8520-48B6C
Console
MGMT
SFP28
USB
Console
SFP28 QSFP28
N8550-48B8C
1 42 3 5 6 7 108 9 11 12 13 1614 15 17 18 19 2220 31 23 24 25 2826 27 29 30 31 3432 33 35 36 37 4038 39 41 42 43 4644 45 47 48
PS1
PS2
FAN
DIAG
LOC
RESET
49 50 51 52 53 54 55 56
49
50
L1 L2 L3 L4
51
52
L1 L2 L3 L4
53
54
L1 L2 L3 L4
55
56
L1 L2 L3 L4
57 58 MGMT CONSOLE
USBCONSOLE
N8550-48B8C
MGMTSFP+
USB
Console MGMT
USB
N8050-32Q
LOC
DIAG
FAN
PS1
PS2
RESET
43
1
21
4
321 24321 44321 64321 84321 10 4321 12 4321 14 4321 16 4321 18 4321 20 4321 22 4321 24 4321 26 4321 28 4321 30 4321 32
4
3
3
21 43
5
21 43
7
21 43
9
21 43
11
21 43
13
21 43
15
21 43
17
21 43
19
21 43
21
21 43
23
21 43
25
21 43
27
21 43
29
21 43
31
21
CONSOLE MGMT
N8050-32Q
QSFP+

N8520-32C
LOC
DIAG
FAN
PS1
PS2
ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
CONSOLE MGMT
RESET LINK/ACTIVITY
N8520-32C
QSFP28 Console MGMT
MGMT
USB
USB
N8550-32C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
LOC
DIAG
FAN
PS1
PS2
RESET
MGMT
CONSOLE SFP+
N8550-32C
QSFP28
Console
Ports Description
SFP+
SFP28
QSFP+
QSFP28
SFP+ ports for 1/10G transceivers
SFP28 ports for 25G transceivers
QSFP+ ports for 40G transceivers
QSFP28 ports for 100G transceivers
MGMT
Console
USB
An Ethernet management port
An RJ45 console port for serial management
A USB2.0 management port
Front Panel Button
N5850-48S6Q
N5850-48S6Q
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
RESETPS1 PS2 DIAG FAN LOC
1 2 3 4
49
1 2 3 4
50
1 2 3 4
51
1 2 3 4
52
1 2 3 4
54
51 54
1 2 3 4
53
MGMT
CONSOLE
LINK ACT
RESET
SFP+

N8520-48B6C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
MGMT CONSOLE
RESETPS1 PS2 DIAG FAN LOC
1234
49
1234
50
1234
51
1234
52
1234
53
1234
54
51 54
N8520-48B6C
N8550-48B8C
N8050-32Q
N8520-32C
LOC
DIAG
FAN
PS1
PS2
ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
CONSOLE MGMT
RESET LINK/ACTIVITY
N8520-32C
RESET
1 42 3 5 6 7 108 9 11 12 13 1614 15 17 18 19 2220 31 23 24 25 2826 27 29 30 31 3432 33 35 36 37 4038 39 41 42 43 4644 45 47 48
PS1
PS2
FAN
DIAG
LOC
RESET
49 50 51 52 53 54 55 56
49
50
L1 L2 L3 L4
51
52
L1 L2 L3 L4
53
54
L1 L2 L3 L4
55
56
L1 L2 L3 L4
57 58 MGMT CONSOLE
USBCONSOLE
N8550-48B8C
RESET
LOC
DIAG
FAN
PS1
PS2
RESET
43
1
21
4
321 24321 44321 64321 84321 10 4321 12 4321 14 4321 16 4321 18 4321 20 4321 22 4321 24 4321 26 4321 28 4321 30 4321 32
4
3
3
21 43
5
21 43
7
21 43
9
21 43
11
21 43
13
21 43
15
21 43
17
21 43
19
21 43
21
21 43
23
21 43
25
21 43
27
21 43
29
21 43
31
21
CONSOLE MGMT
N8050-32Q
RESET
RESET
N8550-32C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
LOC
DIAG
FAN
PS1
PS2
RESET
MGMT
CONSOLE SFP+
N8550-32C
RESET
Button Description
RESET
Restart: Press and release the Reset button quickly.
Restore to Factory Default Settings: Press and hold the Reset button
for more than ve seconds.

Front Panel LEDs
N5850-48S6Q
N5850-48S6Q
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
RESETPS1 PS2 DIAG FAN LOC
1 2 3 4
49
1 2 3 4
50
1 2 3 4
51
1 2 3 4
52
1 2 3 4
54
51 54
1 2 3 4
53
MGMT
CONSOLE
LINK ACT
QSFP+SFP+
PS2PS1 FAN LOC
DIAG LINK ACT
Description
SFP+ port has a valid link at 10G.
Flashing indicates activity.
SFP+ port has a valid link at 1G.
Flashing indicates activity.
On/Flashing
Green
On/Flashing
Amber
O
O
O
Green
On/Flashing
Green
On/Flashing
Green
There is no link on the port.
There is no link on the port.
There is no link on the port.
Switch runs normally.
QSFP+ port has a valid link at 40G.
Flashing indicates activity.
QSFP+ port has a valid link at 10G via
break out cable. The LED on QSFP end
is also present OFF.
LEDs
SFP+
QSFP+ in 40G Mode
QSFP+ in 10G Mode
LINK/ ACT
Status

N8520-48B6C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 53
MGMT CONSOLE
RESETPS1 PS2 DIAG FAN LOC
1234
49
1234
50
1234
51
1234
52
1234
53
1234
54
51 54
N8520-48B6C
QSFP28
SFP28
PS2PS1 FAN LOC
DIAG
Description
25 Gbps mode.
10 Gbps mode.
100 Gbps mode.
Green
Amber
1 LED Green
1 LED Blue
1-4 LEDs Amber
1-4 LEDs Purple
40 Gbps mode.
25 Gbps breakout mode (four lanes).
10 Gbps breakout mode (four lanes).
LEDs
SFP28
QSFP28
Status
N8550-48B8C
1 42 3 5 6 7 108 9 11 12 13 1614 15 17 18 19 2220 31 23 24 25 2826 27 29 30 31 3432 33 35 36 37 4038 39 41 42 43 4644 45 47 48
PS1
PS2
FAN
DIAG
LOC
RESET
49 50 51 52 53 54 55 56
49
50
L1 L2 L3 L4
51
52
L1 L2 L3 L4
53
54
L1 L2 L3 L4
55
56
L1 L2 L3 L4
57 58 MGMT CONSOLE
USBCONSOLE
N8550-48B8C
SFP28 QSFP28
PS2 PS1
FAN
LOC
DIAG
Description
25 Gbps mode.
10 Gbps mode.
100 Gbps mode.
Green
Amber
1 LED Green
1 LED Blue
1-4 LEDs Amber
1-4 LEDs Purple
40 Gbps mode.
25 Gbps breakout mode (four lanes).
10 Gbps breakout mode (four lanes).
LEDs
SFP28
QSFP28
Status

Description
QSFP+ port has a valid link at 40G.
Flashing indicates activity.
On/Flashing
Green
On/Flashing
Orange
On
Green
Flashing
Green
O
O
O
QSFP+ port has a valid link at 10G via
break out cable. Flashing indicates
activity.
There is no link on the port.
Port has a valid link.
There is no link on the port.
Flashing indicates activity.
There is no link on the port.
LEDs
QSFP+
MGMT (Link)
MGMT (Activity)
Status
N8050-32Q
LOC
DIAG
FAN
PS1
PS2
RESET
43
1
21
4
321 24321 44321 64321 84321 10 4321 12 4321 14 4321 16 4321 18 4321 20 4321 22 4321 24 4321 26 4321 28 4321 30 4321 32
4
3
3
21 43
5
21 43
7
21 43
9
21 43
11
21 43
13
21 43
15
21 43
17
21 43
19
21 43
21
21 43
23
21 43
25
21 43
27
21 43
29
21 43
31
21
CONSOLE MGMT
N8050-32Q
QSFP+ MGMT
PS2
PS1
FAN
LOC
DIAG
N8520-32C
LOC
DIAG
FAN
PS1
PS2
ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
CONSOLE MGMT
RESET LINK/ACTIVITY
N8520-32C
QSFP28
PS2
PS1
FAN
LOC
DIAG
Description
100 Gbps mode.
50 Gbps breakout mode (two lanes).
40 Gbps mode.
1 LED Blue
1-2 LEDs Purple
1 LED Orange
1-4 LEDs White
1-4 LEDs Green
25 Gbps breakout mode (four lanes).
10 Gbps breakout mode (four lanes).
LEDs
QSFP28
Status

N8550-32C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
LOC
DIAG
FAN
PS1
PS2
RESET
MGMT
CONSOLE SFP+
N8550-32C
QSFP28 SFP+
PS2
PS1
FAN
LOC
DIAG
Description
Green
Amber
10 Gbps mode.
1 Gbps mode.
LEDs
SFP+
Status
100 Gbps mode.
40 Gbps mode.
25 Gbps breakout mode (four lanes).
10 Gbps breakout mode (four lanes) .
1 LED Blue
1 LED Orange
1-4 LEDs White
1-4 LEDs Green
QSFP28
N Series Switches
Description
PWR is operating normally.
PWR present but not power on or this
power is fault.
Green
Red
O PWR not present.
LEDs
PS1/PS2
Red
Green
O
System self-diagnostic test successfully
completed. (By OS denition)
System self-diagnostic test has detected
a fault.
System o.
DIAG
Status
O
Yellow
Flashing
Flashing by remote management
command. Assists the technician in
nding the right device for the service
in the rack.
Not a particular switch that technician
need to nd.
LOC

DescriptionLEDs Status
Back Panel
N5850-48S6Q
F2B F2B F2B F2B F2B
100~240V-,50~60Hz,6-3APer PS
100~240V-,50~60Hz,6-3A PerPS
Grounding Point
5 Hot-swappable Fans
2 Hot-swappable Power Supplies
N8520-48B6C
F2B F2B F2B F2B F2B F2B
Grounding Point Grounding Point
6 Hot-swappable Fans
2 Hot-swappable Power Supplies
N8550-48B8C
2 Hot-swappable Power Supplies
6 Hot-swappable Fans
PS2 PS2
6 5 4 3 2 1
B2F
21400
B2F
21400
B2F
21400
B2F
21400
B2F
21400
B2F
21400
Grounding Point Grounding Point
N8050-32Q
2 Hot-swappable Power Supplies 5 Hot-swappable Fans
F2BF2B
F2B
1
F2B
2
F2B
3
F2B
4
F2B
5
PS1
PS2
Grounding Point
Red
O
Green
FAN tray present but system FAN is fault.
System FAN operating normally.
System o.
FAN

PS2 PS1
F2B F2B
6
F2B
5
F2B
4
F2B
3
F2B
2 1
2 Hot-swappable Power Supplies
6 Hot-swappable Fans
Grounding Point Grounding Point
N8520-32C
PS2 PS1
F2B F2B
6
F2B
5
F2B
4
F2B
3
F2B
2 1
2 Hot-swappable Power Supplies
6 Hot-swappable Fans
Grounding Point Grounding Point
N8550-32C
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Site Environment
Do not operate it in an area that exceeds an ambient temperature of 45°C.
The installation site must be well ventilated. Ensure that there is adequate air ow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Before you begin the installation, make sure that you have the following:
Installation Requirements
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting network devices.
1
PS1 PS2 DIAG FAN LOC
RESET
2345678910 11 12 13 14 15 16
17 18
49
19 20 21
1234

Mounting the Switch
Attaching the Brackets
1. Attach each of the front- and rear-post brackets to the switch using four M4 screws, and secure each
of the rear-post brackets at the mid-point on the sides of the switch with two M4 screws.
30 31 32
52
33 34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
54
49 50 51 53 MGMT
CONSOLE
LINK ACT
51 54
1 2 3 4
1234
1 2 3 4
2. Use the screws and cage nuts supplied with the rack to secure the switch in the rack.
1
PS1 PS2 DIAG FAN LOC RESET
2345678910 11 12 13 14 15 16
17
1
18
49
19 20 21 22 23 24 25 26 27 28 29 30 31 32
2341
50
2341
51
2341
52
234
33
1
34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
2341
54
23451 54
49 50 51 52
MGMT
CONSOLE
LINK
N5850-48S6Q

Adjusting Rear-Post Bracket Ears
1. First adjust the position of rear-post bracket ears and secure them in the rack.
2. Then lock the position of the rear-post bracket ears using the included ear-locking screw.
100-240V- 50-60Hz,6-3A Perps
F2B
F2B
F2B F2B
Grounding the Switch
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
100-240V- 50-60Hz,6-3A Perps
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.

100-240V- 50-60Hz,6-3A Perps
WARNING: Do not install power cables while the power is on.
Connecting the Power
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
1. Plug the compatible SFP+ transceiver into the SFP+ port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
100-240V- 50-60Hz,6-3A Perps
100-240V- 50-60Hz,6-3A Perps
Connecting the SFP+ Ports
DIAG FAN LOC RESET
345678910 11 12 13 14 15 16
17
1
18
49
19 20 21 22 23 24 25 26 27 28 29 30 31 32
2341
50
2341
51
2341
52
2 3 4
33
1
34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
2341
54
23451 54
49 50 52 53
MGMT
CONSOLE
LINK ACT

Connecting the QSFP+ Ports
1. Plug the compatible QSFP+ transceiver into the QSFP+ port.
2. Connect a ber optic cable to the ber transceivers. Then connect the other end of the cable to
other ber devices.
FAN LOC RESET
45678910 11 12 13 14 15 16
17
1
18
49
19 20 21 22 23 24 25 26 27 28 29 30 31 32
2341
50
2341
51
2341
52
2 3 4
33
1
34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
2341
54
23451 54
49 50 52 53
MGMT
CONSOLE
LINK ACT
Connecting the SFP28 Ports
1. Plug the compatible SFP28 transceiver into the SFP28 port.
2. Connect a ber optic cable to the ber transceivers. Then connect the other end of the cable to
other ber devices.
N8520-48B6C

WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical ber without eye protection.
Connecting the QSFP28 Ports
1. Plug the compatible QSFP28 transceiver into the QSFP28 port.
2. Connect a ber optic cable to the ber transceivers. Then connect the other end of the cable to
other ber devices.
N8520-48B6C
Connecting the Console Port
23 24 25 26 27 28 29 30 31 32
50
3 4 1
51
2 3 4 1
52
2 3 4
33
1
34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
2 3 4 1
54
2 3 4 51 54
49 50 52 53
MGMT
CONSOLE
LINK ACT
1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
2. Connect the other end of the console cable to the RS-232 serial port on the computer.

Connecting the MGMT Port
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the MGMT port on the front of the switch.
FAN LOC RESET
45678910 11 12 13 14 15 16
17
1
18
49
19 20 21 22 23 24 25 26 27 28 29 30 31 32
2341
50
2341
51
2341
52
2 3 4
33
1
34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
2341
54
23451 54
49 50 52 53
MGMT
CONSOLE
LINK ACT
Connecting the USB Port
Insert USB ash disk.
FAN LOC RESET
45678910 11 12 13 14 15 16
17
1
18
49
19 20 21 22 23 24 25 26 27 28 29 30 31 32
2341
50
2341
51
2341
52
2 3 4
33
1
34
53
35 36 37 38 39 40 41 42 43 44 45 46 47 48
2341
54
23451 54
49 50 52 53
MGMT
CONSOLE
LINK ACT
USB

Set up Conguration Environment via Console Port
Step 1: Connect the serial port of a PC (or a terminal) to the console port of the switch with the
console cable.
Step 2: Turn on the PuTTY. Choose the“Serial” as the Protocol.
Step 3: In the Port item, please choose specied COM port that the PC is using.
Step 4: Set the baud rate to 115200, data bit to 8, parity check to none, stop bit to 1, ow control to
none.
Step 5: Enter the default login information:
Username: cumulus
Password: CumulusLinux!
Step 6: Use the corresponding commands to congure the switch or to monitor the running state.
Conguring the Switch (Only for Cumulus Linux Switch)
Install Cumulus Linux license key
There are three ways to install the license onto the switch:
Installing Cumulus® Linux® License Over Switches
Copy and paste the license key into the cl-license command:
cumulus@switch:~$ sudo cl-license -i
<paste license key>
^+d
Copy the license from a local server. Create a text le with the license and copy it to a server
accessible from the switch. On the switch, use the following command to transfer the le directly
on the switch, then install the license le:
cumulus@switch:~$ scp user@my_server:/home/user/my_license_file. txt .
cumulus@switch:~$ sudo cl-license -i my_license_file.txt
Copy the le to an HTTP server (not HTTPS), then reference the URL when you run cl-license:
cumulus@switch:~$ sudo cl-license -i <URL>
CAUTION: It is not necessary to reboot the switch to activate the switch ports. After you
install the license, restart the switchd service. All front panel ports become active and
show up as swp1, swp2, and so on.
cumulus@switch:~$ sudo systemctl restart switchd.service

Troubleshooting for Terminal No-show
After power-on, if the conguration terminal shows nothing, you can rstly check the following:
Troubleshooting for Terminal Show Error Codes
If the conguration terminal shows error codes, it is likely that the terminal (such as the HyperTerminal)
are set incorrectly. Please conrm the parameters of the terminal.
Troubleshooting
According to the power indicator on the front panel, the switches can be used to determine whether
the power system of the switch is faulty. If the power supply system is working normally, the power
indicator should remain lit; If the power indicator is unlit, the power supply system is not working.
Please check the following:
Power System Troubleshooting
After the switch is powered on, if the system is normal, the startup information will be displayed on
the conguration terminal. If there is something wrong with the conguration system, the
conguration terminal may not display or display error codes.
Conguration System Troubleshooting
Whether the switch power cable is connected correctly.
Whether the power supply of the switch matches the required power supply.
If there is no problem with the above, it is very likely that there is a problem with the conguration
cable or the terminal (such as the HyperTerminal) parameters were set incorrectly.
Whether the power supply is normal.
Whether the console cable is properly connected.

Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: N Series Switches enjoy 5 years limited warranty against defect in materials or
workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5
Copyright © 2020 FS.COM All Rights Reserved.
Q.C. PASSED
Other manuals for N Series
2
This manual suits for next models
6
Table of contents
Other FS Switch manuals