manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Power Supply
  8. •
  9. GE GEPS12-25U-NA User manual

GE GEPS12-25U-NA User manual

Other GE Power Supply manuals

GE RAK315D User manual

GE

GE RAK315D User manual

GE GEPS24-20 Manual

GE

GE GEPS24-20 Manual

GE NX-320E User manual

GE

GE NX-320E User manual

GE Tetra GEPS24-100U-NA User manual

GE

GE Tetra GEPS24-100U-NA User manual

GE K 106168E User manual

GE

GE K 106168E User manual

GE LED 55 CC 1.4A ESRDL 1-10V 220-240 User manual

GE

GE LED 55 CC 1.4A ESRDL 1-10V 220-240 User manual

GE Tetra GEPS12-25U-EU User manual

GE

GE Tetra GEPS12-25U-EU User manual

GE CS300 User's guide User manual

GE

GE CS300 User's guide User manual

GE GEPS24-180U Manual

GE

GE GEPS24-180U Manual

GE LED 55 CC 1.4A TBDL 1-10V User manual

GE

GE LED 55 CC 1.4A TBDL 1-10V User manual

GE RAK3153A User manual

GE

GE RAK3153A User manual

GE Infinity M Series User manual

GE

GE Infinity M Series User manual

GE Infinity S User manual

GE

GE Infinity S User manual

GE NX-320E User manual

GE

GE NX-320E User manual

GE Mastr II 19E501149G1 User manual

GE

GE Mastr II 19E501149G1 User manual

GE Digital Energy LP 33 Series User manual

GE

GE Digital Energy LP 33 Series User manual

GE RAK4157 User manual

GE

GE RAK4157 User manual

GE EPS 601 User manual

GE

GE EPS 601 User manual

GE Tetra GEPS12-60U-NA User manual

GE

GE Tetra GEPS12-60U-NA User manual

GE Tetra GEXLPS21 User manual

GE

GE Tetra GEXLPS21 User manual

GE DEH-40417 Operating instructions

GE

GE DEH-40417 Operating instructions

GE Current Tetra GEPS12-25U-EU Manual

GE

GE Current Tetra GEPS12-25U-EU Manual

GE SERIES B 480 User manual

GE

GE SERIES B 480 User manual

GE Current Tetra GEPS12W-60 Manual

GE

GE Current Tetra GEPS12W-60 Manual

Popular Power Supply manuals by other brands

Videx 520MR Installation instruction

Videx

Videx 520MR Installation instruction

Poppstar 1008821 Instructions for use

Poppstar

Poppstar 1008821 Instructions for use

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda 500A instruction manual

TDK-Lambda

TDK-Lambda 500A instruction manual

Calira EVS 17/07-DS/IU operating instructions

Calira

Calira EVS 17/07-DS/IU operating instructions

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Radial Engineering SB-48UB user guide

Radial Engineering

Radial Engineering SB-48UB user guide

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Volt
Installation Guide
Power Supply Features
CAUTION/ATTENTION
RISK OF INJURY
• While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUES DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
®LED Systems
Power Supply
GEPS12-25U-NA
• Supports all 12 VDC Tetra Products
• Dry and Damp Locations Rated
• Class 2 Power Supply
• 120-277 VAC Input
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing
or installing product.
• Properly ground Tetra®power supply.
• Must be enclosed in an end product.
RISK OF FIRE
• In the end product, power supply spacing to other heat
producing components shall be minimum 2 inches spacing to
sidewalls and minimum 2 inches spacing to top of enclosure.
• Adjacent power supplies shall be spaced at least 1 in. end to
end and 4 in. in any other direction.
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm2).
• Follow all local codes.
• Application considerations potentially requiring additional
spacing include high ambient temperature seen by the
power supply, poor contact with a heat dissipating material,
inadequate ventilation, or direct exposure to sun.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra®.
• Doit être inclus à l’intérieur d’un produit nal.
RISQUES D’INCENDIE
• Dans le produit ni, l’espacement entre le bloc d’alimentation et les autres
composants dégageant de la chaleur doit être d’au moins 2 pouces des
parois latérales et d’au moins 2 pouces du haut de l’enceinte.
• Les blocs d’alimentation adjacents doivent être espacés d’au moins 1 po
de bout en bout et 4 po dans toute autre direction.
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux..
• Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d’alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The suitability of rain enclosure shall be determined if
intended for wet location.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
12
Tetra
( VAC input / VDC output / W)120-277 12 25
2
Power Supply Installation
NOTE: For installation in Canada, a disconnect switch of appropriate rating needs to be placed within 29.5 feet (9 meters) of primary
side of the power supply. The switch voltage rating shall not be less than the branch circuit voltage. The switch must also support
twice the amount of input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line, neutral and
ground connections, in accordance with National Electric Code (NEC) Article 600 and all local regulations.
2Connect the AC line to the black
or brown (line) and white or
blue (neutral) input wires of the
power supply using suitable wire
connectors.
Connect the supply wire that is
attached to the Tetra LED System to
the red (+) and black or blue (-) output
wires of the power supply as outlined
in the “Electrical Connections”
section of your LED system’s
Installation Instructions.
NOTE: To avoid overloading this
power supply with LED modules,
please refer to the specic module
loading guides.
3
Input
wires
White or blue
(neutral)
Black or brown
(line)
AC line
To Tetra LED System
Output
wires
Red (+) Black or blue (-)
1Mount the power supply. Mounting
the power supply base directly to
a thermally conductive installation
surface can improve thermal
performance.
NOTE: All electrical connections
should be suitably protected from
mechanical damage and the
environment. Seal all connections
exposed to water with electrical
grade self-hardening silicone.
WARNING
RISK OF ELECTRIC SHOCK
AC input connections shall be
suitably enclosed.
OPTIONAL
A Weather Box (GEXNWB2) may be used to house
and seal Class 2 connections.
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8 (M2
or M3) screw.
Weather box
can be painted
Light engine
A B
GE and the GE Monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or
guarantee, express or implied, that such performance will be obtained under end-use conditions. © 2019 GE Current, a Daintree company.
www.LED.com SIGN077 (Rev 10/28/19) GE2025-6710
Power Supply Specications
Performance Data Min Typical Max
Input Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
THD
PF
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Environmental Rating
Dimensions
Conforms to the following standards:
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
100 120-277 305
- 50/60 -
0.1 (277VAC) -
-
11.0 12.0 13.0
- - 2.0
- - 25
0.3 (100VAC)
- - 20
0.9 -
5.2 in. x 1.6 in. x 1.2 in. (133 mm x 30.5 mm x 40 mm)
-25°C +25°C +50°C*
- - 95%
-10°C - +70°C
For the most up-to-date version of this installation guide, please visit https://products.currentbyge.com/sign-lighting
*Maximum case temperature is °C
75
Symptom Solution
All letters are OFF • Recycle AC power, turn it off, then turn on again.
• If still off, check the power supply DC output voltage using a voltmeter. It should be nominally V.
»If there is DC output, inspect and correct all DC wire damage/polarity issues; If no issue is found, replace the
OFF-module string.
»If there is no DC output, have a licensed electrician check the input AC voltage and if there is correct AC voltage,
replace the power supply.
»If there is no AC voltage, correct the upstream AC issue.
Some LEDs appear dim • Ensure the overall length of the Tetra®LED System does not exceed the maximum load.
• Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the letters
are not illuminated
• Inspect and correct the wires of the non-illuminated letters for damage/polarity issues; If no issues are found, see the
troubleshooting solution for “All letters are OFF.”
Shadows • Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
orientation so that it does not cover any LEDs.
• Adjust LED layout to ensure uniformity of illumination of the face of the letter.
Troubleshooting
IP66 rated: must be protected from direct exposure to the weather
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
12