Location 8 - codes 1 to 10, output enable. This location has 10 segments of feature selection data. When
you activate outputs with a user code (event #30), you can use Location 8 to restrict certain codes from
activating certain outputs. Segment 1 corresponds to user 1; Segment 10 corresponds to user 10. The LEDs
correspond to outputs A to C (see Table 8)..
Location 9 - codes 11 to 20, output enable. This location has 10 segments of feature selection
data.When you activate outputs with a user code (event #30), you can use Location 9 to restrict certain
codes from activating certain outputs. Segment 1 corresponds to user 11; Segment 10 corresponds to user
20. The LEDs correspond to outputs A to C (see Table 8).
Location 10 - codes 21 to 30, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 10 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 21; Segment 10 corresponds to user 30. The
LEDs correspond to outputs A to C (see Table 8).
Location 11 - codes 31 to 40, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 11 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 31; Segment 10 corresponds to user 40. The
LEDs correspond to outputs A to C (see Table 8).
Location 12 - codes 41 to 50, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 12 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 41; Segment 10 corresponds to user 50. The
LEDs correspond to outputs A to C (see Table 8).
Location 13 - codes 51 to 60, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 13 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 51; Segment 10 corresponds to user 60. The
LEDs correspond to outputs A to C (see Table 8).
Location 14 - codes 61 to 70, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 14 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 61; Segment 10 corresponds to user 70. The
LEDs correspond to outputs A to C (see Table 8).
Location 15 - codes 71 to 80, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 15 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 71; Segment 10 corresponds to user 80. The
LEDs correspond to outputs A to C (see Table 8).
Table 8. Output enable
LED Description
1 On if code will activate Output A; Off if it will not.
2 On if code will activate Output B; Off if it will not.
3 On if code will activate Output C; Off if it will not.
4Reserved.