How to adjust your RTU
To check setting:
Use a Torque analyser
To adjust the torque setting:
1. Remove o-ring, retaining pin and hexagon adaptor.
2. Using of 5mm hexagon key, turn ANTICLOCKWISE to release.
3. Remove the 5mm hexagon key, and insert 4mm hexagon key.
4. Turn the 4mm hexagon key CLOCKWISE to INCREASE torque, or
ANTI-CLOCKWISE to REDUCE the torque.
5. Remove 4mm hexagon key and check the torque setting on a
suitable calibration device.
6. Insert 5mm hexagon key, and turn CLOCKWISE to lock off.
7. Replace hexagon adaptor, retaining pin and o-ring.
Servicing Information
Regular servicing of your Torque Tool by competent personnel is important to
ensure it continues to perform correctly.