GEM eSyLite R629 User manual

GEMÜ R629 eSyLite
Motorized diaphragm valve
Operating instructions
EN
further information
webcode: GW-R629

All rights including copyrights or industrial property rights are expressly reserved.
Keep the document for future reference.
© GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
25.06.2021
www.gemu-group.com2 / 41GEMÜ R629 eSyLite

Contents
1 General information ............................................. 4
1.1 Information .................................................... 4
1.2 Symbols used ................................................ 4
1.3 Definition of terms ........................................ 4
1.4 Warning notes ............................................... 4
2 Safety information ............................................... 5
3 Product description ............................................. 5
3.1 Construction .................................................. 5
3.2 Description ..................................................... 5
3.3 Function ......................................................... 5
3.4 Product label ................................................. 6
4 Correct use .......................................................... 6
5 Order data ........................................................... 7
6 Technical data ..................................................... 10
7 Dimensions .......................................................... 15
7.1 Actuator dimensions without position indic-
ator ................................................................. 15
7.2 Actuator dimensions with GEMÜ 1215 posi-
tion indicator .................................................. 16
7.3 Body dimensions ........................................... 17
7.4 Valve body mounting .................................... 27
7.5 Mounting plate .............................................. 28
8 Manufacturer's information .................................. 29
8.1 Delivery .......................................................... 29
8.2 Packaging ...................................................... 29
8.3 Transport ....................................................... 29
8.4 Storage ........................................................... 29
9 Installation in piping ............................................ 29
9.1 Preparing for installation .............................. 29
9.2 Installation position ....................................... 30
9.3 Installation with butt weld spigots ............... 30
9.4 Installation with threaded sockets ............... 30
9.5 Installation with threaded spigots ................ 30
9.6 Installation with union ends .......................... 31
9.7 Installation with solvent cement sockets .... 31
9.8 Installation with flare connection ................. 31
9.9 Installation with flanged connection ............ 31
10 Electrical connection ........................................... 32
10.1 Electrical connection ..................................... 32
11 Operation ............................................................. 33
11.1 Manual override ............................................. 33
12 Inspection and maintenance ................................ 33
12.1 Spare parts .................................................... 34
12.2 Removing the actuator .................................. 34
12.3 Removing the diaphragm .............................. 34
12.4 Mounting the compressor ............................ 34
12.5 Mounting the diaphragm .............................. 34
12.6 Mounting the actuator .................................. 35
13 Troubleshooting .................................................. 36
14 Removal from piping ............................................ 37
15 Disposal .............................................................. 37
16 Returns ................................................................ 37
17 Declaration of Incorporation according to
2006/42/EC (Machinery Directive) ....................... 38
18 Declaration of conformity according to 2014/68/
EU (Pressure Equipment Directive) ...................... 39
19 Declaration of conformity according to 2014/30/
EU (EMC Directive) ............................................... 40
GEMÜ R629 eSyLitewww.gemu-group.com 3 / 41

www.gemu-group.com4 / 41GEMÜ R629 eSyLite
1 General information
1 General information
1.1 Information
•The descriptions and instructions apply to the standard ver-
sions. For special versions not described in this document
the basic information contained herein applies in combina-
tion with any additional special documentation.
•Correct installation, operation, maintenance and repair work
ensure faultless operation of the product.
•Should there be any doubts or misunderstandings, the Ger-
man version is the authoritative document.
•Contact us at the address on the last page for staff training
information.
1.2 Symbols used
The following symbols are used in this document:
Symbol Meaning
Tasks to be performed
Response(s) to tasks
– Lists
1.3 Definition of terms
Working medium
The medium that flows through the GEMÜ product.
Diaphragm size
Uniform seat size of GEMÜ diaphragm valves for different
nominal sizes.
1.4 Warning notes
Wherever possible, warning notes are organised according to
the following scheme:
SIGNAL WORD
Type and source of the danger
Possible
symbol for the
specific
danger
Possible consequences of non-observance.
Measures for avoiding danger.
Warning notes are always marked with a signal word and
sometimes also with a symbol for the specific danger.
The following signal words and danger levels are used:
DANGER
Imminent danger!
▶Non-observance can cause death or
severe injury.
WARNING
Potentially dangerous situation!
▶Non-observance can cause death or
severe injury.
CAUTION
Potentially dangerous situation!
▶Non-observance can cause moderate
to light injury.
NOTICE
Potentially dangerous situation!
▶Non-observance can cause damage to
property.
The following symbols for the specific dangers can be used
within a warning note:
Symbol Meaning
Danger of explosion
Corrosive chemicals!
Hot plant components!
Damage to the product

www.gemu-group.com 5 / 41 GEMÜ R629 eSyLite
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
•Personal hazard due to electrical, mechanical and chemical
effects.
•Hazard to nearby equipment.
•Failure of important functions.
•Hazard to the environment due to the leakage of dangerous
materials.
The safety information does not take into account:
•Unexpected incidents and events, which may occur during
installation, operation and maintenance.
•Local safety regulations which must be adhered to by the
operator and by any additional installation personnel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
12
3
6
7
9
4
8
5
Ite
m
Name Materials
1 Optical position indicator PA 12
2 Manual override
3 Motorized actuator Reinforced polyamide
4 CONEXO actuator RFID chip
5 Valve body Inliner PP-H, grey / outliner
PP, reinforced
Inliner PP-H, natural / out-
liner PP, reinforced
Inliner PVDF / outliner PP,
reinforced
PVC-U, grey
ABS
PP
PP, reinforced
PP-H, natural | PVDF
6 Diaphragm EPDM, FKM, NBR, PTFE/
EPDM
7 CONEXO diaphragm RFID
chip
8 CONEXO body RFID chip
9 Electrical connection
3.2 Description
The GEMÜ R629 eSyLite 2/2-way diaphragm valve is motor-
ized. It is available as an OPEN/CLOSE version. An integral op-
tical position indicator is standard.
3.3 Function
The product controls or regulates (depending on version) a
flowing medium by being closed or opened by a motorized ac-
tuator.
3 Product description

www.gemu-group.com6 / 41GEMÜ R629 eSyLite
4 Correct use
The product has an optical position indicator as standard. The
optical position indicator indicates the OPEN and CLOSED po-
sitions.
3.4 Product label
The product label is located on the actuator. Product label
data (example):
Design in accordance with order data
Device-specific data
Year of manufacture
Item number Traceability number Consecutive number
- XXXXXXXX|YYYY
The month of manufacture is encoded in the traceability num-
ber and can be obtained from GEMÜ. The product was manu-
factured in Germany.
The operating pressure stated on the product label applies to
a media temperature of 20 °C. The product can be used up to
the maximum stated media temperature. You can find the
pressure/temperature correlation in the technical data.
4 Correct use
DANGER
Danger of explosion
▶Risk of death or severe injury.
●Do not use the product in potentially
explosive zones.
WARNING
Improper use of the product
▶Risk of severe injury or death.
▶Manufacturer liability and guarantee will be void.
●Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is designed for installation in piping systems and
for controlling a working medium.
The product is not intended for use in potentially explosive
areas.
●Use the product in accordance with the technical data.

5 Order data
Order codes
The order data provide an overview of standard configurations.
Please check the availability before ordering. Other configurations available on request.
1 Type Code
Diaphragm valve, motorized,
plastic diaphragm valve
R629
2 DN Code
DN 12 12
DN 15 15
DN 20 20
DN 25 25
DN 32 32
DN 40 40
DN 50 50
3 Body configuration Code
2/2-way body D
4 Connection type Code
Threaded socket
Threaded socket DIN ISO 228 1
Solvent cement socket
Solvent cement socket DIN 2
Union end
Union end with insert (socket) – DIN 7
Union end with insert (Rp threaded socket) - DIN 7R
Union end with inch insert - BS (socket) 33
Union end with inch insert – ASTM (socket) 3M
Union end with JIS insert (socket) 3T
Union end with insert (for IR butt welding) – DIN 78
Spigot
Spigot DIN 0
Spigot for IR butt welding 20
Spigot for IR butt welding, BCF 28
Imperial butt weld spigot 30
Flange
Flange EN 1092, PN 10, form B,
face-to-face dimension FTF EN 558 series 1, ISO
5752, basic series 1
4
Flange ANSI Class 125/150 RF,
face-to-face dimension FTF EN 558 series 1, ISO
5752, basic series 1,
length only for body configuration D
39
Flare
Flare connection with PVDF union nut 75
5 Valve body material Code
PVC-U, grey 1
5 Continuation of Valve body material Code
ABS 4
PP, reinforced 5
PVDF 20
Inliner PP-H, grey,
outliner PP, reinforced
71
Inliner PVDF/outliner PP, reinforced 75
PP-H, natural N5
6 Diaphragm material Code
Elastomer
NBR 2
FKM 4
EPDM 29
PTFE
PTFE/EPDM one-piece 54
7 Voltage/Frequency Code
24 V DC C1
8 Control module Code
Open/Close control (economy) A0
Open/Close control (economy),
with emergency power supply module (NC)
A1
Open/Close control (economy),
with emergency power supply module (NO)
A2
Open/Close control, mounted position indicator
GEMU 1215
Z0
Open/Close control, mounted position indicator
GEMU 1215,
emergency power supply module (NC)
Z1
Open/Close control, mounted position indicator
GEMU 1215,
emergency power supply module (NO)
Z2
9 Actuator version Code
Actuator size 1
diaphragm size 10
1C
Actuator size 1
diaphragm size 20
1E
Actuator size 1
diaphragm size 25
1F
Actuator size 3
diaphragm size 40
3H
10 Mounting plate Code
With mounting plate M
Without mounting plate O
5 Order data
www.gemu-group.com 7 / 41 GEMÜ R629 eSyLite

10 Continuation of Mounting plate Code
Standard
5 Order data
www.gemu-group.com8 / 41GEMÜ R629 eSyLite

Order example
Ordering option Code Description
1 Type R629 Diaphragm valve, motorized,
plastic diaphragm valve
2 DN 25 DN 25
3 Body configuration D 2/2-way body
4 Connection type 7 Union end with insert (socket) – DIN
5 Valve body material 1 PVC-U, grey
6 Diaphragm material 29 EPDM
7 Voltage/Frequency C1 24 V DC
8 Control module A0 Open/Close control (economy)
9 Actuator version 1E Actuator size 1
diaphragm size 20
10 Mounting plate Standard
5 Order data
www.gemu-group.com 9 / 41 GEMÜ R629 eSyLite

6 Technical data
6.1 Medium
Working medium: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and diaphragm material.
The valve will seal in both flow directions up to full operating pressure (gauge pressure).
6.2 Temperature
Media temperature: Valve body material Media temperature
PVC-U, grey (code 1) 10 — 60 °C
ABS (code 4) 10 — 60 °C
PP, reinforced (code 5) 5 – 80 °C
PVDF (code 20) -10 — 80 °C
Inliner PP-H grey / outliner PP, reinforced (code
71)
5–80 °C
Inliner PVDF / outliner PP, reinforced (code 75) -10 — 80 °C
PP-H, natural (code N5) 5–80 °C
Ambient temperature: Valve body material Ambient temperature
PVC-U, grey (code 1) 10 — 50 °C
ABS (code 4) -10 — 50 °C
PP, reinforced (code 5) 5 — 50 °C
PVDF (code 20) 0 — 50 °C
Inliner PP-H grey / outliner PP, reinforced (code
71)
5 — 50 °C
Inliner PVDF / outliner PP, reinforced (code 75) -5 — 50 °C
PP-H, natural (code N5) 5 — 50 °C
If the emergency power module is used (control module code A1, A2), the maximum ambient tem-
perature is reduced to 40 °C.
6.3 Pressure
Operating pressure: 0 — 6 bar
All pressures are gauge pressures. Operating pressure values were determined with static operating pressure
applied on one side of a closed valve. Sealing at the valve seat and atmospheric sealing is ensured for the given
values.
Information on operating pressures applied on both sides and for high purity media on request.
The operating pressures apply at room temperature. In case of deviating temperatures, observe the pressure /
temperature correlation.
Pressure rating: MG 10 PN 6
MG 20 - 40 PN 10
www.gemu-group.com10 / 41GEMÜ R629 eSyLite
6 Technical data

Pressure/temperature
correlation:
Pressure/temperature correlation PN 6
Valve body material Temperature in °C (valve body)
Materials Code -10 0 5 10 20 25 30 40 50 60 70 80
PVC-U 1 - - - 6.0 6.0 6.0 4.8 3.6 2.1 0.9 - -
PP 5 - - 6.0 6.0 6.0 6.0 5.1 4.2 3.3 2.4 - -
PP-H N5 - - 6.0 6.0 6.0 6.0 5.1 4.2 3.3 2.4 - -
PVDF 20 6.0 6.0 6.0 6.0 6.0 6.0 5.4 4.8 4.3 3.8 6.0 6.0
Pressure/temperature correlation PN 10
Valve body
material
Temperature in °C (valve body)
Materials Code -10 0 5 10 20 25 30 40 50 60 70 80
PVC-U 1 - - - 10.0 10.0 10.0 8.0 6.0 3.5 1.5 - -
ABS 4 10.0 10.0 10.0 10.0 10.0 10.0 8.0 6.0 4.0 2.0 - -
PP-H 71 - - 10.0 10.0 10.0 10.0 8.5 7.0 5.5 4.0 2.7 1.5
PVDF 75 10.0 10.0 10.0 10.0 10.0 10.0 9.0 8.0 7.1 6.3 5.4 4.7
The pressure rating (PN) depends on the diaphragm size.
Data for extended temperature ranges on request. Please note that the ambient temperature and media temper-
ature generate a combined temperature at the valve body which must not exceed the above values.
Leakage rate: Leakage rate A to P11/P12 EN 12266-1
Kv values: MG Nominal size Kv value
MG 10 DN 12 2.8
DN 15 3.5
DN 20 3.5
MG 20 DN 15 6.0
DN 20 10.0
DN 25 12.0
MG 25 DN 32 20.0
MG 40 DN 40 42.0
DN 50 46.0
Kv values in m³/h
MG = diaphragm size
Kv values determined acc.to DIN EN 60534 standard, inlet pressure 5 bar, Δp 1 bar, PVC-U valve body and soft
elastomer diaphragm.
The Kv values for other product configurations (e.g. other diaphragm or body materials) may differ. In general,
all diaphragms are subject to the influences of pressure, temperature, the process and their tightening torques.
Therefore the Kv values may exceed the tolerance limits of the standard.
The Kv value curve (Kv value dependent on valve stroke) can vary depending on the diaphragm material and dur-
ation of use.
GEMÜ R629 eSyLitewww.gemu-group.com 11 / 41
6 Technical data

6.4 Product compliance
Machinery Directive: 2006/42/EC
Pressure Equipment Dir-
ective:
2014/68/EU
EMC Directive: 2014/30/EU
Technical standards used:
Interference emission: DIN EN 61800-3
Interference resistance: DIN EN 61326-1 (industrial processes)
DIN EN 61800-3
Food: FDA*
USP* Class VI
* depending on version and/or operating parameters
6.5 Materials
Materials: Diaphragm material O-ring material
PTFE FPM
NBR EPDM
FPM FPM
EPDM EPDM
www.gemu-group.com12 / 41GEMÜ R629 eSyLite
6 Technical data

6.6 Mechanical data
Protection class: IP 65 acc. to EN 60529
Actuating speed: Max. 2 mm/s
Flow direction: Optional
Installation position: Optional
Observe the angle of rotation to achieve an installation for optimized draining
Weight: Actuator
MG 10: 0.8 kg
MG 20: 0.88 kg
MG 25: 0.94 kg
MG 40: 1.4 kg
Body
Connection
types
Code 1)
0, 30 20 28 7, 7R 33 3M,
3T
78 4, 39 1 75 2
MG DN
10 12 - - - - - - - - 0.08 - 0.06
15 - - 0.13 0.18 0.13 - - - - 0.08 -
20 ---------0.125-
20 15 0.12 0.10 - 0.17 0.24 0.26 0.27 0.67 - - -
20 0.13 0.12 - 0.21 0.28 0.30 0.36 0.84 - - -
25 0.16 0.14 - 0.26 0.33 0.38 0.37 1.28 - - -
25 32 0.22 0.18 - 0.40 0.70 0.73 0.63 1.89 - - -
40 40 0.50 0.40 - 0.73 0.83 0.93 1.13 2.36 - - -
50 0.57 0.47 - 1.00 1.40 1.50 1.60 3.08 - - -
Weights in kg
1) Connection type
Code 0: Spigot DIN
Code 1: Threaded socket DIN ISO 228
Code 2: Solvent cement socket DIN
Code 3M: Union end with inch insert – ASTM (socket)
Code 3T: Union end with JIS insert (socket)
Code 4: Flange EN 1092, PN 10, form B, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series
1
Code 7: Union end with insert (socket) – DIN
Code 7R: Union end with insert (Rp threaded socket) - DIN
Code 20: Spigot for IR butt welding
Code 28: Spigot for IR butt welding, BCF
Code 30: Imperial butt weld spigot
Code 33: Union end with inch insert - BS (socket)
Code 39: Flange ANSI Class 125/150 RF, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic
series 1, length only for body configuration D
Code 75: Flare connection with PVDF union nut
Code 78: Union end with insert (for IR butt welding) – DIN
6.7 Duty cycle and service life
Service life: Class A acc. to EN 15714-2
Minimum 100,000 switching cycles at room temperature and permissible duty cycle.
Duty cycle: max. 30% duty
GEMÜ R629 eSyLitewww.gemu-group.com 13 / 41
6 Technical data

6.8 Electrical data
Supply voltage: 24 V DC
Tolerance ± 10 %
Operating time: MG 10: 2.5 s
MG 20: 3.5 s
MG 25: 4.0 s
MG 40: 4.5 s
Close tight current / rated
current:
MG 10: 0.5 A
MG 20: 1.4 A
MG 25: 1.3 A
MG 40: 2.3 A
Starting current / max-
imum current:
MG 10: approx. 2.4 A
MG 20: approx. 2.4 A
MG 25: approx. 2.4 A
MG 40: approx. 4.5 A
Standby current con-
sumption:
approx. 10 mA
6.8.1 Digital input signals
Input voltage: max. 30 V DC
High level: ≥ 18 V DC
Low level: ≤ 5 V DC
6.8.2 Emergency power supply module
Charging current: MG 10, MG 20, MG 25: max. 0.16 A
MG 40: 0.32 A
Charging time: approx. 13 min
Service life: Guide value at 25 °C ambient temperature, approx. 3 years
www.gemu-group.com14 / 41GEMÜ R629 eSyLite
6 Technical data

7 Dimensions
7.1 Actuator dimensions without position indicator
B2
A
A1
B1
B3
B
MG A A1 B B1 B2 B3
10 192.0 63.0 59.5 134.5 115.0 82.0
20 195.0 66.0 59.5 134.5 115.0 82.0
25 204.0 75.0 59.5 134.5 115.0 82.0
40 228.0 91.0 80.0 167.0 147.5 94.5
Dimensions in mm
MG = diaphragm size
* CT = A + H1 (see body dimensions)
GEMÜ R629 eSyLitewww.gemu-group.com 15 / 41
7 Dimensions

7.2 Actuator dimensions with GEMÜ 1215 position indicator
AZ2
A
AZ1
BZ2 BZ1
MG A AZ1 AZ2 BZ1 BZ2
10 237.0 72.0 61.0 30.0 40.0
20 240.0 72.0 61.0 30.0 40.0
25 249.0 72.0 61.0 30.0 40.0
40 273.0 72.0 61.0 30.0 40.0
Dimensions in mm
MG = diaphragm size
www.gemu-group.com16 / 41GEMÜ R629 eSyLite
7 Dimensions

7.3 Body dimensions
7.3.1 Spigot DIN / inch (code 0, 30)
L
c
Ød
H1
H
Connection type spigot DIN (code 0) 1), body material PVC-U (code 1), inliner/outliner (code 71, 75) 2)
MG DN NPS c ød H H1 L
Material Material
1 71, 75 1 71, 75
20 15 1/2" 16.0 18.0 20.0 36.0 36.0 10.0 124.0
20 3/4" 19.0 19.0 25.0 38.0 38.0 12.0 144.0
25 1" 22.0 22.0 32.0 39.0 39.0 13.0 154.0
25 32 1¼" 32.0 32.0 40.0 41.0 41.0 15.0 174.0
40 40 1½" 35.0 26.0 50.0 63.2 63.2 23.2 194.0
50 2" 38.0 33.0 63.0 63.2 63.2 23.2 224.0
Connection type spigot inch (code 30) 1), body material PVC-U (code 1), ABS (code 4) 2)
MG DN NPS c ød H H1 L
20 15 1/2" 24.0 21.4 36.0 10.0 141.0
20 3/4" 27.0 26.7 38.0 12.0 144.0
25 1" 30.0 33.6 39.0 13.0 154.0
25 32 1¼" 33.0 42.2 41.0 15.0 174.0
40 40 1½" 35.0 48.3 63.2 23.2 194.0
50 2" 40.0 60.3 63.2 23.2 224.0
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 0: Spigot DIN
Code 30: Imperial butt weld spigot
2) Valve body material
Code 1: PVC-U, grey
Code 4: ABS
Code 5: PP, reinforced
Code 20: PVDF
Code 71: Inliner PP-H, grey, outliner PP, reinforced
Code 75: Inliner PVDF/outliner PP, reinforced
GEMÜ R629 eSyLitewww.gemu-group.com 17 / 41
7 Dimensions

7.3.2 Spigot IR (code 20)
L
c
Ød
H1
H
s
Connection type spigot IR (code 20) 1), body material inliner/outliner (code 71, 75) 2)
MG DN NPS c ød H H1 L s
Material
71 75
20 15 1/2" 33.0 20.0 36.0 10.0 154.0 1.9 1.9
20 3/4" 33.0 25.0 38.0 12.0 154.0 2.3 1.9
25 1" 33.0 32.0 39.0 13.0 154.0 2.9 2.4
25 32 1¼" 33.0 40.0 41.0 15.0 194.0 3.7 2.4
40 40 1½" 33.0 50.0 63.2 23.2 194.0 4.6 3.0
50 2" 33.0 63.0 63.2 23.2 224.0 5.8 3.0
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 20: Spigot for IR butt welding
2) Valve body material
Code 71: Inliner PP-H, grey, outliner PP, reinforced
Code 75: Inliner PVDF/outliner PP, reinforced
www.gemu-group.com18 / 41GEMÜ R629 eSyLite
7 Dimensions

7.3.3 Spigot (code 28)
c1
L
ød
H1
H
c
3
s
Connection type spigot (code 28) 1), body material PVDF (code 20) 2)
MG DN NPS c c1 ød H H1 L s
10 15 1/2'' 31.0 37.0 20.0 41.0 16.0 134.0 1.9
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 28: Spigot for IR butt welding, BCF
2) Valve body material
Code 20: PVDF
GEMÜ R629 eSyLitewww.gemu-group.com 19 / 41
7 Dimensions

7.3.4 Union end DIN (code 7)
L1
H1
H
L2
R
ØD
Ød
Connection type union end DIN (code 7) 1), body material PVC-U (code 1), PP (code 5), PVDF (code 20), PP-H (code N5), dia-
phragm size 10 2)
MG DN NPS ød øD H H1 L1 L2 R
Material Material Material
1, 20 5, N5 1, 20 5, N5 1, 20 5, N5
10 15 1/2" 20.0 43.0 30.0 41.0 15.0 16.0 90.0 128.0 125.0 G 1
Connection type union end DIN (code 7) 1), body material PVC-U (code 1), ABS (code 4), inliner/outliner (code 71, 75) 2),
diaphragm size 20 – 40
MG DN NPS ød øD H H1 L1 L2 R
Material
1 4 71 75
20 15 1/2" 20.0 43.0 36.0 10.0 108.0 146.0 150.0 143.0 146.0 G 1
20 3/4" 25.0 53.0 38.0 12.0 108.0 152.0 156.0 146.0 150.0 G 1¼
25 1" 32.0 60.0 39.0 13.0 116.0 166.0 170.0 158.0 162.0 G 1½
25 32 1¼" 40.0 74.0 41.0 15.0 134.0 192.0 196.0 181.0 184.0 G 2
40 40 1½" 50.0 83.0 63.2 23.2 154.0 222.0 222.0 207.0 210.0 G 2¼
50 2" 63.0 103.0 63.2 23.2 184.0 266.0 266.0 245.0 248.0 G 2¾
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 7: Union end with insert (socket) – DIN
2) Valve body material
Code 1: PVC-U, grey
Code 4: ABS
Code 5: PP, reinforced
Code 20: PVDF
Code 71: Inliner PP-H, grey, outliner PP, reinforced
Code 75: Inliner PVDF/outliner PP, reinforced
Code N5: PP-H, natural
www.gemu-group.com20 / 41GEMÜ R629 eSyLite
7 Dimensions
Other manuals for eSyLite R629
3
Table of contents
Other GEM Control Unit manuals