GeoVision GV- RK1352 User manual

July 14, 2015
1
GV-RK1352 / R1352 / DFR1352 Card Reader
The content of this installation guide refers to the following readers:
•GV-RK1352 firmware V1.2
•GV-R1352 firmware V1.2
•GV-DFR1352 (Rev. B) firmware V1.2
Introduction
GV-RK1352 / R1352 / DFR1352 are card readers capable of recognizing identification cards.
GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. GV-DFR1352 is
designed to be installed on the door frame.
Featured with the Wiegand and RS-485 outputs, the readers can be connected to any
standard access control panel. The readers are protected by a weather sealed and IP66
compliant housing for outdoor use.

July 14, 2015
2
Packing List
GV-RK1352
1. GV-RK1352 Card Reader
2. Screw x 2
3. Screw Anchor x 2
4. Front Cover Plate x 2
5. Software CD
6. Warranty Card
GV-R1352
1. GV-R1352 Card Reader
2. Screw x 3
3. Screw Anchor x 2
4. Security Torx
5. Software CD
6. Warranty Card
GV-DFR1352
1. GV-DFR1352 Card Reader
2. Screw x 2
3. Screw Anchor x 2
4. Front Cover Plate x 2
5. Software CD
6. Warranty Card

July 14, 2015
3
1. Physical Descriptions
1.1 Electric Wire
GV-RK1352
Wire Color Function
Red DC 7.5 ~ 12 V
Black GND
Yellow Beeper
Orange Green LED
Light Red Red LED
Green Wiegand Data 0
White Wiegand Data 1
Blue RS-485 +
Light Blue RS-485 -
Rear View
GV-R1352
Wire Color Function
Red DC 7.5 ~ 12V
Black GND
Yellow Beeper
Orange Green LED
Light Red Red LED
Green Wiegand Data 0
White Wiegand Data 1
Blue RS-485 +
Light Blue RS-485 -
Gray N/A
Purple N/A
Brown N/A Rear View

July 14, 2015
4
GV-DFR1352
Wire Color Function
Red DC 7.5 ~ 12V
Black GND
Yellow Beeper
Orange Green LED
Light Red Red LED
Green Wiegand Data 0
White Wiegand Data 1
Blue RS-485 +
Light Blue RS-485 -
Gray N/A
Purple N/A
Brown N/A Rear View
Install the GV-DFR1352 to the door frame using the supplied screws and screw anchors.
Before placing and sticking the front cover plate to the GV-DFR1352, remove the Plastic
Cover to prevent scratches to the cover after installed.

July 14, 2015
5
1.2 Keypad (GV-RK1352 Only)
When accessing an entry using GV-RK1352, you can enter the door’s PIN code on the
keypad or present the card and then enter the card’s PIN code on the keypad to be granted
access. The access mode is defined on GV-ASManager.
1. 0~9 Number Keys: Press the number keys to enter the PIN code.
2. # Key: Press the # key to confirm the PIN code.
3. ﹡Key: Press the ﹡key to cancel the PIN code.
1.3 LED Indicator and Beeper
In standby mode, the LED is blue. When a card is read, the LED flashes green and the
beeper beeps once.
The reader comes with external control wires for Green LED, Red LED and Beeper. You can
connect these control wires to a GV-AS Controller to change the default settings of the LED
and Beeper. For details on how to configure the settings, refer to 5. Changing the Settings of
Beeper and LED later in this installation guide.
Note: You can only connect the LED and beeper wires to GV-AS210 / 2110 / 410 / 4110 /
810 / 8110.

July 14, 2015
6
2. Connecting the Reader to GV-AS Controller
You can connect the readers to GV-AS Controllers through Wiegand or RS-485 interface.
Note that the connection between the reader and GV-AS Controller varies with different
controller models. To see how many readers can be connected to a GV-AS Controller, refer
to The Number of Readers Supported by GV-AS Controllers table at the end of this
installation guide.
Note:
1. GV-RK1352 / R1352 / DFR1352 is compatible with GV-AS100 / 1010 / 110 / 120 / 210
/ 2110 / 410 / 4110 / 810 / 8110. However, to enable the keypad function on GV-
RK1352, you can only connect GV-RK1352 to the controllers through the following
interfaces.
•GV-AS100 / 110 / 120: through Wiegand interface
•GV-AS1010: through RS-485 interface
•GV-AS210 / 2110 / 410 / 4110 / 810 / 8110: through Wiegand or RS-485 interface
2. Each GV-RK1352 / R1352 / DFR1352 consumes 60 mA of power. The total power
consumption of the output devices and readers connected to the GV-AS Controller
must be under 3A (for GV-AS210 / 2110), 3.5A (for GV-AS410 / 4110) or 5A (for GV-
AS810 / 8110). Connect an external power supply if the power supplied from GV-AS
Controller is insufficient.
2.1 Connecting through Wiegand Interface
The following diagrams use GV-RK1352 and GV-AS810 Controller as an example. Up to
eight readers can be connected to GV-AS810 Controller through the controller’s Wiegand
interface.
Wire Color Function
Black GND
White Wiegand Data 1
Green Wiegand Data 0
Red DC 7.5 ~ 12V
(Black)
(Green)
(White)
(Red)
GND
D1
D0
12V
Wiegand A
GV-AS810 Controller GV-RK1352
or GV-R1352
Note: Connection through Wiegand interface is not supported for GV-AS1010.

July 14, 2015
7
2.2 Connecting through RS-485 Interface
The following diagrams use GV-RK1352 and GV-AS810 Controller as an example. Up to
eight readers can be connected together to the RS-485 interface on GV-AS810 Controller.
zConnecting four or less readers to GV-AS810 Controller:
Wire Color Function
Black GND
Light Blue RS-485 -
Blue RS-485 +
Red DC 7.5 ~ 12V
zConnecting five or more readers to GV-AS810 Controller:
For readers five to eight, connect the RS-485 cable to the RS-485 interface on GV-
AS810 Controller and then connect the 12V power output and GND of the reader to a
12V DC power output on the controller.

July 14, 2015
8
2.2.1 Defining Readers on GV-AS Controller Web Interface
Since multiple readers can connect to GV-AS Controller using one RS-485 interface, you
need to specify which door each reader controls. This section explains how to define readers
on the Web interface of GV-AS Controller. On the Web interface, you can also set the reader
to read the GID or UID on GV-AS ID Cards / Key Fobs. Note that the Web interface of
different GV-AS Controller models varies.
1. On the controller’s Web interface, click Extended Reader. This dialog box appears.
2. In the GV-Reader/CR420/GF1921/GF1922 section, select the RS485 checkbox in front of
the ID number and type the Serial Number on the rear panel of the reader. The ID
number will be assigned to the reader.
3. Select a door/gate for the reader from the Function drop-down list.

July 14, 2015
9
4. Next to Read Mode, select Read UID or Read GID to set the connected readers to read
UID (unique identifier) or GID (GeoVision ID) on GV-AS ID Cards / Key Fobs.
If you select Read GID, make sure there are two numbers on your GV-AS ID Cards / Key
Fobs as shown below. If there is only one number on your GV-AS ID Cards / Key Fobs,
GID is not supported, and you must select Unique Identification (UID).
5. Click Submit.
Note:
1. When you click Submit on the Extended Reader page of a GV-AS1010 / 210 / 2110 /
410 / 4110 / 810 / 8110, all readers connected through RS-485 interface will reboot.
2. GID ID format is only supported in GV-RK1352 / GV-R1352 / GV-DFR1352 (Rev. B)
V1.2 or later.
3. If you are using third-party cards or key fobs, you must set the reader to read UID.

July 14, 2015
10
3. Installing the GV-R/RK/DFR Config AP
The GV-R/RK/DFR Config AP allows you to set the reader’s beeper / LED, ID number,
master / slave status, and whether it reads UID or GID. When using the Config AP, the
reader needs to be connected to a PC through GV-COM, GV-Hub or GV-NET/IO Card V3.1.
You can install the Config AP from the Software DVD or GeoVision Website. To use a GV-
COM, GV-Hub or GV-NET/IO Card V3.1, you also need to install GeoVision USB Device
Driver.
Installing from Software CD
1. Insert the software CD and the Install Program window will pop up automatically.
2. Select Install GeoVision USB Device Driver.
3. In the GeoVision USB Driver Installer window that appears, select Install.
4. Go back to the Install Program window, and select Run GV-Reader Config Utility.
Downloading from GeoVision Website
1. Go to the Software Download and Upgrading page of GeoVision Website:
http://www.geovision.com.tw/english/5_8_AS.asp
2. Select GV-Reader from the drop-down list, and click the Download icon of
GV-RK1352 & GV-R1352 & GV-DFR1352 Config Utility.
3. Select Driver from the drop-down list and click the Download icon of GV-
USB Device Driver.

July 14, 2015
11
4. Overlaying Card Numbers on GV-System Live
View
You can overlay card numbers recognized at the reader onto a camera channel on GV-
System. To overlay card numbers on GV-System channel, the reader needs to be connected
to a GV-System through GV-COM, GV-Hub or GV-NET/IO Card V3.1.
RS-485
GV-HUB / GV-COM /
GV-NET/IO Card
RS-232
GV-System
(Light Blue) RS-485 -
(Blue) RS-485 +
USB
GV-RK1352
or GV-R1352
Note: GV-RK1352 / R1352 / DFR1352 is not compatible with GV-NET Card and GV-
NET/IO Card of versions earlier than V3.
4.1 Defining the ID Number and Setting the Reader to Slave
After the reader is connected to the computer of the GV-System, use the GV-R/RK/DFR
Config AP to define the ID number of the reader and set the reader to Slave.
1. Run GV-R/RK/DFR Config AP. Refer to 3. Installing the GV-R/RK/DFR Config AP above
for how to install.

July 14, 2015
12
2. Select the COM port that is connected to the reader and click Open COM. The serial
number and firmware version of the reader will be automatically detected. The red square
next to the COM port box should change to blue to indicate the COM port is correct.
3. Under Master / Slave, set the reader to Slave.
4. Select an ID number for the reader. The ID number ranges from 0 to 7.
5. Click Setup. The settings are sent to the reader.
If you want to connect multiple readers to the GV-System, you need to set up a unique ID
number for each reader. For this you need to connect each reader to the computer one
reader at a time, and follow the instructions above to set up an ID number.
Note:
1. If the COM port is incorrect, an “Error opening serial port”message will appear. To
verify the COM port that is connected to the reader, go to Windows Device Manager. In
the Ports (COM & LPT) field, you should see the entry for Prolific USB-to-Serial
Comm Port and the COM number currently in use.
2. If you are using an older version of the Config AP, you will have to manually type the
serial number of the reader. The serial number is on the rear panel of the reader.

July 14, 2015
13
4.2 Adding the Reader to GV-System
1. In GV-System, click the Configure button, select Accessories, and select GV Wiegand
Capture Device Setting. This dialog box appears.
2. Click the New button. This dialog box appears.
Type: Select GV-Wiegand Capture.
Device: Type a number and name to help you identify the reader.
COM: Select the COM port connected to the reader.
Address: Select the ID of the connected reader you set in GV-R/RK/DFR Config AP.
Camera: Assign the reader to a channel to overlay card numbers on the live view.
3. Click the Add button.

July 14, 2015
14
5. Changing the Default Settings of Beeper and LED
You can change the default settings of the LED and the beeper by enabling a GV-AS210 /
2110 / 410 / 4110 / 810 / 8110 to externally control the LED and Beeper. Through the Web
interface, you can set the controller to trigger the red LED, green LED or beeper when the
specified alarm events occur.
The GV-AS Controller and the reader need to be connected through Wiegand interface. You
will have to:
1. Enable external control of the reader’s Beeper and LED by using the GV-R/RK/DFR
Config AP.
2. Wire the Beeper, Red LED and Green LED from the reader to the GV-AS Controller.
3. Specify the Beeper and LED settings for each door through the Web interface of GV-AS
Controller.
5.1 Setting up Beeper and LED on GV-R/RK/DFR Config AP
To enable the external controls of the Beeper and LED on GV-R/RK/DFR Config AP, the
reader needs to be connected to a computer through GV-COM, GV-Hub or GV-NET/IO Card
V3.1.
1. Start the GV-R/RK/DFR Config AP and select the COM port that is connected to the
reader.
Note: To see how to install the Config AP and how to identify the COM port of the reader,
refer to 3. Installing GV-R/RK/DFR Config AP and 4.1 Defining the ID Number and Setting
the Reader to Slave earlier in this installation guide

July 14, 2015
15
2. Click Open COM. The serial number and the firmware version of the reader will be
automatically detected.
3. To enable external control of Beeper or LED, select Beeper, Green LED or Red LED.
4. Select Master from the Master / Slave drop-down list.
5. Select an ID number for the reader. Make sure the ID number on the Config AP matches
the ID number set on the Extended Reader page of the GV-AS Controller Web interface.
6. Click Setup. The settings are sent to the reader.
If you want to set up multiple readers to be controlled by the controller, you need to connect
each reader to the computer one reader at a time, and follow the above instructions to
enable external control.
After the above settings, you need to connect the Beeper, Red LED and Green LED wires
from the reader to the outputs of GV-AS Controller.

July 14, 2015
16
5.2 Wiring the Beeper and LED to the GV-AS Controller
To wire the beeper and LED to GV-AS210 / 2110 / 410 / 4110 / 810 / 8110, connect the
control wires of the reader’s Beeper, Red LED or Green LED to any of the outputs on GV-AS
Controller.
Wiring LED to GV-AS Controller
The diagram below shows the connection for wiring Green LED using GV-RK1352 and GV-
AS810 as an example. For Red LED, use the light red wire instead.
Wire Color Function
Black GND
Orange Green LED
Light Red Red LED
OUT11
OUT12
Wiring Beeper to GV-AS Controller
The diagram below shows the connection for wiring the beeper using GV-RK1352 and GV-
AS810 as an example.
Wire Color Function
Black GND
Yellow Beeper
OUT11
OUT12

July 14, 2015
17
After wiring, you also need to go to GV-ASManager to select the alarm conditions that will set
off the reader’s beeper. In GV-ASManager, right-click the GV-AS Controller in the device list,
click Settings, and click the Door / Gate tab to select the alarm conditions.
5.3 Configuring the Beeper and LED Settings for Each Door/Gate
After connecting the wires for beeper or LED, specify the conditions to trigger the beeper and
LED on the GV-AS210 / 2110 / 410 / 4110 / 810 / 8110 Web interface.
1. On the controller Web interface, click Output Setting. The page below appears.
2. Find the output wired to the beeper or LED and specify up to 2 alarm conditions to set off
the beeper or LED.
a. Output Type: Select Normal, Toggle or Pulse. If you select Pulse, you can specify
the number of seconds to trigger the beeper or LED.
b. Output Conditions: Select the door and the alarm conditions to trigger the beeper
or LED. Up to 2 sets of output conditions can be set.
3. Click Submit.

July 14, 2015
18
6. Setting UID or GID on GV-R/RK/DFR Config AP
By default, the readers read the UID (unique identifier) on ID cards or key fobs. Using GV-
R/RK/DFR Config AP, you can set the GV-RK1352 / R1352 / DFR1352 to read GID
(GeoVision ID) on GV-AS ID Cards / Key Fobs instead.
Note:
1. To see how to install the Config AP and how to identify the COM port of the reader,
refer to 3. Installing GV-R/RK/DFR Config AP and 4.1 Defining the ID Number and
Setting the Reader to Slave earlier in this installation guide
2. GID ID format is only supported in GV-RK1352 / GV-R1352 / GV-DFR1352 (Rev. B)
V1.2 or later.
3. If you are using third-party cards or key fobs, you must set the reader to read UID.
1. Run GV-R/RK/DFR Config AP.
2. Select the COM port that is connected to the reader and click Open COM. The serial
number and firmware version of the reader will be automatically detected. The red square
next to the COM port box should change to blue to indicate the COM port is correct.
3. To set the reader to read GID, select Only Read GID.

July 14, 2015
19
4. Click Setup to apply the setting.
To use GID, make sure there are two numbers on your GV-AS ID Cards / Key Fobs as
shown below. If there is only one number on your GV-AS ID Cards / Key Fobs, GID is not
supported and you must select Unique Identification (UID).

July 14, 2015
20
7. Firmware Upgrade
GeoVision will periodically release the updated firmware on the website. The new firmware
can be simply loaded into the reader by using Update Utility included in the Software CD.
Important Notes before You Start
Before you start updating the firmware, please read these important notes:
1. While the firmware is being updated, the power supply must not be interrupted.
2. Do not turn the power off within 10 minutes after the firmware is updated.
WARNING: The interruption of power supply during updating causes not only update
failures but also damages to the device. In this case, please contact your sales
representative and send your device back to GeoVision for repair.
To upgrade firmware:
1. Insert the Software CD and select Run Firmware Update Utility. This dialog box
appears.
2. Select the COM port of the reader.
3. Click the Browse button to locate the firmware file (.bin) saved at your local computer.
4. Click Update.
5. The LED indicator should flash purple during the process of firmware upgrading. When
the process is complete, the reader will be sounded twice and the LED indicator will
change to green.
Note: You can also download the firmware upgrade utility from the GeoVision website:
http://www.geovision.com.tw/english/5_8_AS.asp. Select GV-Reader from the drop-down
list, click the Download icon of GV-RK1352 & GV-R1352 & GV-DFR1352
Firmware Upgrade Utility.
Other manuals for GV- RK1352
3
This manual suits for next models
4
Table of contents
Other GeoVision Card Reader manuals

GeoVision
GeoVision GV-PCR310 User manual

GeoVision
GeoVision GV-PCR1251 User manual

GeoVision
GeoVision GV-R1352 User manual

GeoVision
GeoVision GV- RK1352 User manual

GeoVision
GeoVision GV-R1352 User manual

GeoVision
GeoVision GV- RK1352 User manual

GeoVision
GeoVision GV-R1352 V2B User manual

GeoVision
GeoVision GV- RK1352 User manual

GeoVision
GeoVision GV-R1352 V2B User manual

GeoVision
GeoVision GV-Reader 1251 User manual