About Battery Operation
About PV Master Operation and Monitoring
About EzMeter and Power Limit Function
Other Questions
Questions & Answers (Q & A)
About Wi-Fi Configuration
A: Normally Solar-WiFi signal could be searched right after inverter powered up. But Solar-WiFi signal
will disappear when ES connected to internet. If need change settings, can connect to the router to
change. If cannot see WiFi signal even not connect to router, then please try to reload WiFi (please
refer to ES user manual page 18)
Q: Why cannot see Solar-WiFi signal on mobile devices
A: It is the character of the Wi-Fi module that it can connect to only one device at a time. If the signal is
connected to another device at the time for some reason, then you cannot connect to the signal.
Q: Why cannot connect Solar-Wifi signal on my phone?
A: For Back-Up supply, the “Back-Up Function” on PV Master App must be turned on. Under off-grid
mode or grid power is disconnected, “Off-Grid Out” function must be turned on as well
Note: As turn “Off-Grid Output” on, don’t restart inverter or battery, otherwise the function will switch off
automatically.
Q: Why there is output on Back-Up side?
A: This normally happens on lead-acid batteries or when BMS communication fail on lithium battery. If
battery enter float charge, SOC will be reset to 95% compulsively.
Q: On Portal, why battery SOC has a sudden jump up to 95%?
A: For LG battery, it will stop charge at SOC 95%. It is normal about LG battery. And also battery will
stop charge when battery voltage reaches charge voltage set on PV Master APP
Q: Why battery cannot be fully charged to 100%
A: For lithium battery like LG, normally the switch trips for flowing reason:
1.BMS communication fails, or battery SOC is so low to protect itself.
2.Battery SOC is too low, battery trips to protect itself.
3.An electrical short-cut happened on battery connection side. Or other reasons please contact
GoodWe for details.
Q: Why battery switch always trip when starts it up (Lithium battery)?
A: For EM inverters, it could connect lithium or lead-acid batteries, with nominal voltage 48V, max
charge voltage 60V
Compatible lithium batteries for now: LG RESU3.3/6.5/10, BYD B-Box 2.5/5.0/7.5/10,
GCL5.6KWh, Pylon US2000B (1~4 packs). For lead-acid batteries: please contact GoodWe to
confirm if it is suitable to use.
Q: Which battery should I use for EM?
2.Make sure EM under waiting mode (on APP) before you change any settings on PV Master APP ---
disconnect grid/load/battery, only leave PV connected and then restart EM till see work mode as “wait”
on APP.
A: This could be caused by losing connection to Solar-WiFi.
1.Make sure you connected Solar-WiFi (make sure no other devices connected) or router (if
connected Solar-WiFi to router) and on APP home page shows connection well.
Q: Why Cannot save settings on PV Master App
A: As the data on APP is from inverter and on home page and Param page, the data refresh frequency
is different, so there will be a data inconformity between different pages on APP as well as between
that on portal and APP
Q: On the App, why the data on the homepage and Param page is different, like charge/discharge,
PV value, load value or grid value?
A: NA means App does not receive data from inverter or server, normally it is because
communication problem, such as battery communication, and communication between inverter and
the APP.
Q: On App, some columns show NA, like battery SOH, etc. why is that?
A: Export limit could theoretically to minimum 0W, but there will have a deviation of around 50-100W
for ES system.
Q: Why there is still power exporting to grid after I set power limit as 0W?
A: Cannot, because there the communication protocol is inset between inverter and EzMeter, other
brand Meter cannot communicate. Also any manual setting change could cause EzMeter
communication failure.
Q: Can I use other brand Meter to take over EzMeter in EM system or change some settings on
EzMeter?
A: The max current for CT is 120A
Q: What is the max current allowed going through CT on EzMeter?
A: The shortest way, please refer to QUICK INSTALLATION INSTRUCTIONS and PV MASTER
APP INSTRUCTION
Q: Is there a quick way to make the system work?
A: Please refer to user manual on page 12
Q: What kind of load can I connect on Back-Up side?
A: Normally if any problem caused by disobey the instructions on user manual, we can provide
technical support to help solve the problem, but cannot guarantee a replacement or returns. So if
there is any special condition when you cannot 100% follow the instructions, please contact GoodWe
for suggestions.
Q: Whether the warranty of the inverter still valid if the installation or operation does not follow
the user manual instructions, for some special conditions when we cannot 100% follow them?
A: On APP, Off-Grid Output and backup function should be turned on to make battery discharge
under off-grid mode.
Q: Why battery does not discharge when grid is not available, while it discharge normally when
grid is available?
A: For EM system, the function could be realized by:
1. Make sure EzMeter connection and communication well
2. Turn on Export Power Limit function and Set the max output power to grid on APP
Q: How to Act Output Power Limit function?
Note: If Out-put Power Limit set as 0W, then there might still have deviation max 100W exporting to grid.