• The information in this guide is subject to change due to product updates or other reasons.
This guide cannot replace the product labels or the safety precautions in the user manual
unless otherwise specied. All descriptions here are for guidance only.
• Before installations, read through the quick installation guide. For additional information,
please see the user manual.
• All operations should be performed by trained and knowledgeable technicians who are
familiar with local standards and safety regulations.
• Check the deliverables for correct model, complete contents, and intact appearance. Contact
after sales service if any damage is found or any component is missing.
• Use insulating tools and wear personal protective equipment when operating the equipment
to ensure personal safety. Wear anti-static gloves, clothes, and wrist strips when touching
electronic devices to protect the inverter from damage.
• Strictly follow the installation, operation, and conguration instructions in this guide. The
manufacturer shall not be liable for equipment damage or personal injury if you do not follow
the instructions. For more warranty details, please visit https://www.goodwe.com/support-
service/warranty-related
DC Side:
1. Ensure the component frames and the bracket system are securely grounded.
2. Connect the DC cables using the delivered PV connectors. The manufacturer shall not be
liable for the equipment damage if other connectors or terminals are used.
3. Ensure the DC cables are connected tightly, securely and correctly. Inappropriate wiring
may cause poor contacts or high impedances, and damage the inverter.
4. Measure the DC cable using the multimeter to avoid reverse polarity connection. Also,
the voltage should be under the permissible range. The manufacturer shall not be liable
for the damage caused by reverse connection and extremely high voltage.
5. The PV modules used with the inverter must have an IEC61730 class A rating. Never
grounding positive or negative of the PV module.
6. Do not connect one PV string to more than one inverter at the same time. Otherwise, it
may cause damage to the inverter.
AC Side:
1. The voltage and frequency at the connecting point should meet the on-grid
requirements.
2. Additional protective devices like circuit breakers or fuses are recommended on the AC
side. Specication of the protective device should be at least 1.6 times the max AC output
current.
3. You are recommended to use copper cables as AC output cables. A copper to aluminum
adapter terminal is required when an aluminum cable is used.