3
SAFETY NOTICE
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DANGER
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
CAREFULLY FOLLOW THESE INSTRUCTIONS.
To reduce the risk of electric shock, disconnect power to the 120V
electrical outlet before installing or removing the unit. When removing
the electrical wall plate, it may fall across plug pins or become displaced.
To reduce the risk of electric shock, this product has a grounding type
plug that has a third (grounding) pin. This plug will only fit into a
grounding type power outlet. If the plug does not fit into the outlet,
contact a qualified electrician to install the proper outlet. Do not change
the plug in any way.

4
PRODUCT DETAILS
Operaon and Specificaons
Input/Output voltage: 120V.
Output current: rated 15A for general purpose load.
DAY or NIGHT ON mes range from 5 seconds to 60 minutes.
DAY or NIGHT OFF mes range from 1 minute to 12 hours.
Unit starts with ON me at power up in DAY condion. When unit switches
to NIGHT, Night OFF me is started. When the unit returns to DAY, Day ON
me is started.
Electrical specificaons: See the rang label on your product.

5
INSTALLATION & OPERATION
DAY AND NIGHT DETECTION
The photocell detects a NIGHT condion when it senses darkness for
a minimum period of 8 seconds.
The photocell detects a DAY condion when it senses light for a
minimum period of 8 seconds
DISABLING OPERATION
In order to disable DAY or NIGHT operaon, set corresponding ON me to
"zero" - turn knob counter clockwise unl all bars are OFF when seng
DAY ON or NIGHT ON mes.
BOTTOM BAR IS BLINKING
The boom bar of display is flashing at the end of a cycle. The bar will
flash for 2 seconds at the end of an ON me, and for 30 seconds at the
end of an OFF me.
Bargraph Display
Use SCALE on LEFT SIDE for ON mes
(5 seconds to 60 minutes)
Use SCALE on RIGHT SIDE for OFF
mes
(1 minute to 12 hours)
Light sensor (photocell)
120V Output plug

6
Set Values
INSTALLATION & OPERATION
Click knob to select mes and turn to set values in
this order:
· DAY ON me: Indicator is steady lit (not blinking), rotate knob to
select from 5 seconds to 60 minutes (le side scale).
· NIGHT ON me: Indicator is steady lit (not blinking), rotate knob
to select from 5 seconds to 60 minutes (le side scale).
· DAY OFF me: Indicator is steady lit (not blinking), rotate knob
to select from 1 minute to 12 hours (right side scale).
· NIGHT OFF me: Indicator is steady lit (not blinking), rotate knob
to select from 1 minute to 12 hours (right side scale).
Night ON Time
Indicator Day OFF Time
Indicator
Night OFF Time
Indicator
Day ON Time
Indicator
Photocell

7
Connect your equipment
Connect your pump or other equipment into the 120V outlet in front of
your mer.
BLINKING INDICATOR AND TIME COUNTDOWN
A blinking indicator shows you which "me" is currently running.
Countdown is shown on display at all mes during normal cycle operaon.
The bargraph display
shows a remaining
me of 15 seconds.
DAY is detected and ON me will run for 15 more seconds before it
switches to OFF me.
NIGHT is detected and OFF me will run for 35 more minutes before it
switches to ON me.
INSTALLATION & OPERATION
Exemple 1:
DAY ON Indicator is blinking.
Display bar "15" is lit (le scale).
Exemple 2:
NIGHT OFF Indicator is blinking.
Display bar "30" and "40" are lit (right scale).
The bargraph display
shows a remaining me
of 35 minutes.

8
= Steps
QUICK TROUBLESHOOTING GUIDE
Quick Troubleshoong Chart
Product Model: CY3
BEFORE YOU START
· Perform test in a bright room
· You will need a load to plug into UNIT*
Push knob
once
Turn knob both
sides to raise
me to 60 min
and then back
to 10 sec
Yes
No
Product
Defecve
Yes
Day On
Time LED
turns On
A B C D
Plug UNIT
Display bars
will light On
from boom to
top & top to
boom
Push knob
once
Product
Defecve
Product
Defecve
Product
Defecve
Day On Time LED DOES
NOT turn On
Display bars DOES NOT
light up & down
Night On Time
LED DOES NOT
turn On
Night On Time
LED turn On
Display bars
light up &
down

9
QUICK TROUBLESHOOTING GUIDE
Product
Defecve
Product
Good
*Before test, check if load is working properly.
E F G H
I
J K
Wait 1 min, for
complete cycle
(UNIT in Day
Off Time)
Turn knob to
adjust Day Off
Time at 1 min
Push knob
twice
Plug load into
UNIT
Cover photocell
with hand palm
& wait 10 sec
Push knob
once
Uncover photo-
cell & wait 10
sec
Day Off Time LED
DOES NOT turn On
Day Off Time LED
turns On
Day Off Time set at
1 min
Day Off Time NOT
set at 1 min
UNIT goes back
to normal oper-
aon
UNIT DOES NOT go
back to normal
operaon
Load
On
Load Off
Aer 10 sec, Day
On Time LED
remains On
Aer 10 sec, Off
Night Time LED
turns On
Aer 10 sec, Night
Off Time LED
remains On
Aer 10 sec, Day
On Time LED
turns On
Aer 1 min,
load Off
Product
Defecve
Load
On

10
COMPLETE TROUBLESHOOTING GUIDE
Digital cycle mer with display
CY3
1 – Before you start
2 – Test
· DO NOT CONNECT UNIT
BEFORE STEP 1 OF THE TEST.
· CONNECT A LOAD INTO THE
FRONT OUTLET
OF THE UNIT.
· LIGHTHING
CONDITION:
perform this test in a room with
enough light for the unit to
detect a DAY condion.
STEPS HANDLING AND TEST
DESCRIPTIONS EXPECTED RESULTS
1 · Plug unit into a power outlet.
When power is applied, each
bar of the display is lit
individually from boom to
top and back to boom.
DAY ON me Indicator is
BLINKING.
Load connected to 120V front
outlet is ON.
Night ON Time
Indicator Day OFF Time
Indicator
Night OFF Time
Indicator
Day ON Time
Indicator
Photocell
Click knob to select and
turn to set values
NOTE: read ON mes on the LEFT scale and OFF mes on the RIGHT scale.
*IMPORTANT: READ AND FOLLOW THESE INSTRUCTIONS BEFORE
STARTING THE TEST.

11
COMPLETE TROUBLESHOOTING GUIDE
STEPS HANDLING AND TEST
DESCRIPTIONS EXPECTED RESULTS
2
· Click knob once to enter Times
Sengs
· Turn knob to set DAY ON me
to 10 seconds (2nd bar is lit).
DAY ON me indicator is
STEADY LIT.
2nd bar of display (from
boom) is STEADY LIT.
The load connected to 120V
front outlet will remain in
the same state it was (ON or
OFF, when Times Seng was
entered). Time countdown is
suspended.
3
· Click knob once
· Turn knob to set NIGHT ON
me to 60 seconds (6th bar is
lit).
NIGHT ON me indicator is
STEADY LIT.
6th bar of display (from
boom) is STEADY LIT.
4
· Click knob once
· Turn knob to set DAY OFF me
to 1 minute (1st bar is lit).
DAY OFF me indicator is
STEADY LIT.
1st bar of display (from
boom) is STEADY LIT.
5
· Click knob once.
· Turn knob to set NIGHT OFF
me to 10 minutes (4th bar is
lit).
NIGHT OFF me indicator is
STEADY LIT.
4th bar of display (from
boom) is STEADY LIT.

12
COMPLETE TROUBLESHOOTING GUIDE
STEP HANDLING AND TEST
DESCRIPTIONS EXPECTED RESULTS
6 · Click knob once to resume
normal operaon.
DAY ON me or DAY OFF me
indicator is BLINKING,
meaning ON or OFF me
countdown is underway.
The unit will cycle 10 seconds
ON followed by 1 minute OFF.
Observe one complete ON-
OFF cycle and verify ON and
OFF mes.
LOAD must be ON when
either DAY ON me or NIGHT
ON me indicator is lit.
7
· Cover the Light Sensor
completely with the palm of
your hand or black electrical
tape (a single finger will NOT
cover the sensor
appropriately) and wait 8
seconds unl the NIGHT
condion is met.
DAY OFF me and DAY ON
me indicators (i.e. both
"Sun" icons) turn OFF.
NIGHT OFF me indicator
starts BLINKING and 4th bar
turns ON.
8
· Uncover the Light Sensor and
wait 8 sec unl DAY condion
is met.
4th bar turns OFF.
NIGHT OFF me and NIGHT
ON me indicators (i.e. both
"Moon" icons) turn OFF.
DAY ON me indicator starts
BLINKING and 2nd bar turns
ON.

13
WARRANTY & CUSTOMER SERVICE
DO YOU HAVE A PROBLEM WITH YOUR CONTROLLER ? PLEASE READ
THESE INSTRUCTIONS CAREFULLY AND SAVE THEM FOR FUTURE
REFERENCE.
1. I think my controller is damaged, or it simply does not work as
indicated in the user guide, what should I do?
· Please refer to the troubleshoong steps. Follow these instrucons
carefully, step by step. The controller should work as described in the
“Expected results” column of the Complete Troubleshoong Guide.
Do you need assistance on execung the Troubleshoong steps?
1. Contact us at 1-855-262-1800
2. Send us an EMAIL at ser[email protected]
3. VISIT our Technical Support Center at
www.grozonecontrol.com/techsupport.html
Technical Support is available Monday through Friday, from 8:00 AM to
8:00 PM, Eastern Time.

14
2. I’ve been through the troubleshoong steps. What do I do if I meet a
problem at any of these steps? Is my product covered by the
WARRANTY?
· Grozone controllers are covered by a 3-year warranty (*). We will
replace any DAMAGED PRODUCT WITH A BRAND NEW PRODUCT.
· Covered or not covered? We do not authorize the replacement of fully
working products nor altered (tampered) products. The Troubleshoong
steps will help you idenfy a damaged product. Do not hesitate to
contact us or contact your retailer to make sure the controller is not fully
working or damaged before returning it to the store.
· My product is not fully working or damaged, I want a replacement unit:
in order to get a replacement product, you MUST return all modules
and applicable accessories to the retailer. To avoid being charged for
the accessories, be sure to include all pieces. Thanks for your
cooperaon.
· Any Grozone Control product that is returned with obvious signs of user
neglect will not be covered by the warranty. Grozone Control exercises
the right to make final decisions in these maers.
(*)The warranty period begins from the date of purchase at the retail level. The
retailer/consumer must keep their proof of sale/purchase. Otherwise, Grozone
Control will consider the manufacturing date to apply the warranty coverage.
IMPORTANT MESSAGE TO RETAILERS
Retailers must call Grozone Control to get authorisaon to replace the
defecve product and a RMA number.
1-855-262-1800
WARRANTY & CUSTOMER SERVICE

15
NOTE

Rev. 3.0
www.grozonecontrol.com
Other manuals for CY3
1
Table of contents
Other Grozone Control Timer manuals

Grozone Control
Grozone Control CY3 Operating instructions

Grozone Control
Grozone Control Cyclestat-3 CY3 User manual

Grozone Control
Grozone Control TP24H User manual

Grozone Control
Grozone Control CY1 User manual

Grozone Control
Grozone Control TP24H User manual

Grozone Control
Grozone Control CY1 User manual