SAFETY NOTICE
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DANGER
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
CAREFULLY FOLLOW THESE INSTRUCTIONS.
To reduce the risk of electric shock disconnect power to the 120V
electrical outlet before installing or removing the unit. When removing
the electrical wall plate it may fall across plug pins or become displaced.
To reduce the risk of electric shock this product has a grounding type
plug that has a third (grounding) pin. This plug will only fit into a
grounding type power outlet. If the plug does not fit into the outlet
contact a qualified electrician to install the proper outlet. Do not change
the plug in any way.
SAFETY NOTICE
3

PRODUCT DETAILS
Operation and Specifications
Input/Output voltage: 120V.
Output current: rated 15A for general purpose load.
DAY or NIGHT ON times range from 5 seconds to 60 minutes.
DAY or NIGHT OFF times range from 1 minute to 12 hours.
Unit starts with ON time at power up in DAY condition. When unit switches
to NIGHT Night OFF time is started. When the unit returns to DAY Day ON
time is started.
Electrical specifications: See the rating label on your product.
PRODUCT DETAILS
4

INSTALLATION & OPERATION
DAY AND NIGHT DETECTION
The photocell detects a NIGHT condition when it senses darkness for
a minimum period of 8 seconds.
The photocell detects a DAY condition when it senses light for a
minimum period of 8 seconds
DISABLING OPERATION
In order to disable DAY or NIGHT operation set corresponding ON time to
"zero" - turn knob counter clockwise until all bars are OFF when setting
DAY ON or NIGHT ON times.
BOTTOM BAR IS BLINKING
The bottom bar of display is flashing at the end of a cycle. The bar will
flash for 2 seconds at the end of an ON time and for 30 seconds at the
end of an OFF time.
Bargraph Display
Use SCALE on LEFT SIDE for ON times
(5 seconds to 60 minutes)
Use SCALE on RIGHT SIDE for OFF
times
(1 minute to 12 hours)
Light sensor (photocell)
120V Output plug
INSTALLATION & OPERATION
5

Set Values
INSTALLATION & OPERATION
Click knob to select times and turn to set values in
this order:
•
DAY ON time: Indicator is steady lit (not blinking) rotate knob to
select from 5 seconds to 60 minutes (left side scale).
•
NIGHT ON time: Indicator is steady lit (not blinking) rotate knob
to select from 5 seconds to 60 minutes (left side scale).
•
DAY OFF time: Indicator is steady lit (not blinking) rotate knob
to select from 1 minute to 12 hours (right side scale).
•
NIGHT OFF time: Indicator is steady lit (not blinking) rotate knob
to select from 1 minute to 12 hours (right side scale).
Night ON Time
Indicator Day OFF Time
Indicator
Night OFF Time
Indicator
Day ON Time
Indicator
Photocell
INSTALLATION & OPERATION
6

Connect your equipment
Connect your pump or other equipment into the 120V outlet in front of
your timer.
BLINKING INDICATOR AND TIME COUNTDOWN
A blinking indicator shows you which "time" is currently running.
Countdown is shown on display at all times during normal cycle operation.
The bargraph display
shows a remaining
time of 15 seconds.
DAY is detected and ON time will run for 15 more seconds before it
switches to OFF time.
INSTALLATION & OPERATION
Exemple :
DAY ON Indicator is blinking.
Display bar "15" is lit (left scale).
Exemple 2:
NIGHT OFF Indicator is blinking.
Display bar "30" and "40" are lit (right scale).
The bargraph display
shows a remaining time
of 35 minutes.
INSTALLATION & OPERATION
7
NIGHT is detected and OFF time will run for 35 more minutes before it
switches to ON time.

= Steps
QUICK TROUBLESHOOTING GUIDE
Quick Troubleshooting Chart
Product Model:
CY3
BEFORE YOU START
•
Perform test in a bright room
•
You will need a load to plug into UNIT*
Push knob
once
Turn knob both
sides to raise
time to 60 min
and then back
to 10 sec
Yes
No
Product
Defective
Day On
Time LED
turns On
A B C D
Plug UNIT
Display bars
will light On
from bottom to
top & top to
bottom
Push knob
once
Product
Defective
Product
Defective
Product
Defective
Day On Time LED DOES
NOT turn On
Display bars DOES NOT
light up & down
Night On Time
LED DOES NOT
turn On
Night On
Time LED
turn On
Display bars
light up &
down
QUICK TROUBLESHOOTING GUIDE
8

QUICK TROUBLESHOOTING GUIDE
Product
Defective
Product
Good
*Before test check if load is working properly.
E F G H
I
J K
Wait 1 min for
complete cycle
(UNIT in Day
Off Time)
Turn knob to
adjust Day Off
Time at 1 min
Push knob
twice
Plug load into
UNIT
Cover photocell
with hand palm
& wait 10 sec
Push knob
once
Uncover photo-
cell & wait 10
sec
Day Off Time LED
DOES NOT turn On
Day Off Time LED
turns On
Day Off Time set at
1 min
Day Off Time NOT
set at 1 min
UNIT goes back
to normal op-
eration
UNIT DOES NOT go
back to normal
operation
Load
On
Load Off
After 10 sec Day
On Time LED
remains On
After 10 sec Off
Night Time LED
turns On
After 10 sec Night
Off Time LED
remains On
After 10 sec Day
On Time LED
turns On
After 1 min
load Off
Product
Defective
Load
On
QUICK TROUBLESHOOTING GUIDE
9

COMPLETE TROUBLESHOOTING GUIDE
Digital cycle timer with display
CY3
1 – Before you start
2 – Test
•
DO NOT CONNECT UNIT
BEFORE STEP OF THE TEST.
•
CONNECT A LOAD INTO THE
FRONT OUTLET
OF THE UNIT.
•
LIGHTHING
CONDITION:
perform this test in a room with
enough light for the unit to
detect a DAY condition.
STEPS HANDLING AND TEST
DESCRIPTIONS EXPECTED RESULTS
1
•
Plug unit into a power outlet.
When power is applied each
bar of the display is lit
individually from bottom to
top and back to bottom.
DAY ON time Indicator is
BLINKING.
Load connected to 20V front
outlet is ON.
Night ON Time
Indicator Day OFF Time
Indicator
Night OFF Time
Indicator
Day ON Time
Indicator
Photocell
Click knob to select and
turn to set values
NOTE: read ON times on the LEFT scale and OFF times on the RIGHT scale.
*IMPORTANT: READ AND FOLLOW THESE INSTRUCTIONS BEFORE
STARTING THE TEST.
COMPLETE TROUBLESHOOTING GUIDE
10

COMPLETE TROUBLESHOOTING GUIDE
STEPS HANDLING AND TEST
DESCRIPTIONS EXPECTED RESULTS
2
•
Click knob once to enter Times
Settings
•
Turn knob to set DAY ON time
to 10 seconds (2nd bar is lit).
DAY ON time indicator is
STEADY LIT.
2nd bar of display (from
bottom) is STEADY LIT.
The load connected to 20V
front outlet will remain in
the same state it was (ON or
OFF, when Times Setting was
entered). Time countdown is
suspended.
3
•
Click knob once
•
Turn knob to set NIGHT ON
time to 60 seconds (6th bar is
lit).
NIGHT ON time indicator is
STEADY LIT.
6th bar of display (from
bottom) is STEADY LIT.
4
•
Click knob once
•
Turn knob to set DAY OFF time
to 1 minute (1st bar is lit).
DAY OFF time indicator is
STEADY LIT.
1st bar of display (from
bottom) is STEADY LIT.
5
•
Click knob once.
•
Turn knob to set NIGHT OFF
time to 10 minutes (4th bar is
lit).
NIGHT OFF time indicator is
STEADY LIT.
4th bar of display (from
bottom) is STEADY LIT.
COMPLETE TROUBLESHOOTING GUIDE
11

COMPLETE TROUBLESHOOTING GUIDE
STEP HANDLING AND TEST
DESCRIPTIONS EXPECTED RESULTS
6
•
Click knob once to resume
normal operation.
DAY ON time or DAY OFF time
indicator is BLINKING
meaning ON or OFF time
countdown is underway.
The unit will cycle 10 seconds
ON followed by 1 minute OFF.
Observe one complete ON-
OFF cycle and verify ON and
OFF times.
LOAD must be ON when
either DAY ON time or NIGHT
ON time indicator is lit.
7
•
Cover the Light Sensor
completely with the palm of
your hand or black electrical
tape (a single finger will NOT
cover the sensor
appropriately) and wait 8
seconds until the NIGHT
condition is met.
DAY OFF time and DAY ON
time indicators (i.e. both
"Sun" icons) turn OFF.
NIGHT OFF time indicator
starts BLINKING and 4th bar
turns ON.
8
•
Uncover the Light Sensor and
wait 8 sec until DAY condition
is met.
4th bar turns OFF.
NIGHT OFF time and NIGHT
ON time indicators (i.e. both
"Moon" icons) turn OFF.
DAY ON time indicator starts
BLINKING and 2nd bar turns
ON.
COMPLETE TROUBLESHOOTING GUIDE
12

WARRANTY & CUSTOMER SERVICE
DO YOU HAVE A PROBLEM WITH YOUR CONTROLLER ? PLEASE READ
THESE INSTRUCTIONS CAREFULLY AND SAVE THEM FOR FUTURE
REFERENCE.
. I think my controller is damaged, or it simply does not work as
indicated in the user guide, what should I do?
•
Please refer to the troubleshooting steps. Follow these instructions
carefully step by step. The controller should work as described in the
“Expected results” column of the Complete Troubleshooting Guide.
Do you need assistance on executing the Troubleshooting steps?
. Contact us at -855-262- 800
2. Send us an EMAIL at service@grozonecontrol.com
3. VISIT our Technical Support Center at
www.grozonecontrol.com/techsupport.html
Technical Support is available Monday through Friday from 8:00 AM to
8:00 PM Eastern Time.
WARRANTY & CUSTOMER SERVICE
13

2. I’ve been through the troubleshooting steps. What do I do if I meet a
problem at any of these steps? Is my product covered by the
WARRANTY?
•
Grozone controllers are covered by a 3-year warranty (*). We will
replace any DAMAGED PRODUCT WITH A BRAND NEW PRODUCT.
•
Covered or not covered? We do not authorize the replacement of fully
working products nor altered (tampered) products. The Troubleshooting
steps will help you identify a damaged product. Do not hesitate to
contact us or contact your retailer to make sure the controller is not fully
working or damaged before returning it to the store.
•
My product is not fully working or damaged I want a replacement unit:
in order to get a replacement product you MUST return all modules
and applicable accessories to the retailer. To avoid being charged for
the accessories be sure to include all pieces. Thanks for your
cooperation.
•
Any Grozone Control product that is returned with obvious signs of user
neglect will not be covered by the warranty. Grozone Control exercises
the right to make final decisions in these matters.
(*)
The warranty period begins from the date of purchase at the retail level. The
retailer/consumer must keep their proof of sale/purchase. Otherwise Grozone
Control will consider the manufacturing date to apply the warranty coverage.
IMPORTANT MESSAGE TO RETAILERS
Retailers must call Grozone Control to get authorisation to replace the
defective product and a RMA number.
-855-262- 800
WARRANTY & CUSTOMER SERVICE
14

NOTE
15


GUIDE DE L’USAGER
CY3
Séquenceur numérique
www.grozonecontrol.com

TABLE DES MATIÈRES
NOTICE DE SÉCURITÉ 3
FICHE DE PRODUIT 4
INSTALLATION & OPÉRATION 5-6-7
GUIDE DE DÉPANNAGE RAPIDE 8-9
GUIDE DE DÉPANNAGE COMPLET 0- - 2
SERVICE À LA CLIENTÈLE ET GARANTIE 3- 4

NOTICE DE SÉCURITÉ
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
CONSERVEZ CES INSTRUCTIONS
DANGER
POUR RÉDUIRE LES RISQUES D'INCENDIE OU DE CHOCS ÉLECTRIQUES
SUIVRE ATTENTIVEMENT CES INSTRUCTIONS.
Pour réduire le risque de chocs électriques coupez le courant de la prise
de courant avant d'installer ou d'enlever l'unité. En enlevant la vis
retenant le couvercle de la prise 120V celui-ci peut tomber sur les fiches
et les court-circuiter ou encore la prise pourrait se déplacer.
Pour réduire le risque de chocs électriques ce produit possède une fiche
dont la troisième broche sert à la mise à la terre. Cette fiche ne se
connecte uniquement que dans les prises possédant une mise à la terre.
Si votre prise ne possède pas cette mise à la terre contactez un
électricien qualifié pour l'installation d'une prise appropriée. Ne modifiez
pas la fiche du produit.
3

FICHE DE PRODUIT
Fonctionnement et caractéristiques
Voltage entrant / sortant : 120V.
Ampérage de sortie : 15A pour charge à utilisation générale.
Temps ON de JOUR et de NUIT de 5 secondes à 60 minutes.
Temps OFF de JOUR et de NUIT de 1 minute à 12 heures.
Le contrôleur démarre avec le temps ON de JOUR. Lorsque l’unité détecte le
mode de NUIT le temps OFF de NUIT est en vigueur. Lorsqu’il retourne de
JOUR le contrôleur retombe en Temps ON de JOUR.
Spécifications électriques : Voir la plaque signalétique sur le produit.
4
Table of contents
Languages:
Other Grozone Control Timer manuals
Popular Timer manuals by other brands

Schrack Technik
Schrack Technik AMPARO ZRAE0011 Assembly instructions

Digi
Digi DT800 operating instructions

Oregon Scientific
Oregon Scientific TR112 user manual

Full Gauge Controls
Full Gauge Controls ICEMATIC quick start guide

Raindrip
Raindrip R675CT Installation & programming

Tekmar
Tekmar Timer 031 Data brochure