12
BATIUM 7/12 • 7/24 • 15/12 • 15/24 EN
Translation of the original instructions
TROUBLESHOOTING
ANOMALIES CAUSES SOLUTIONS
1The charge indicator 1 is swit-
ched off. The battery voltage
indicators blink alternatively
after 1 minute of charging.
The selected voltage does not
match the battery voltage.
- Disconnect the machine from the
mains while keeping the clamps connec-
ted to the battery.
- Choose the right voltage
- Then reconnect the BATIUM to the
battery.
The battery cannot be recovered. Change the battery.
2The battery capacity indica-
tors ash alternatively.
The battery is in short circuit or
damaged Change the battery.
A power consumer has been left
on accidentally (e.g. lights). Switch off the power consumer and
continue/restart the charge
The charger is used as a power
supply to compensate for the use
of power consumers that are drag-
ging the battery's energy.
Charger behaves normally but incorrect
use. The indicator that signals the end
of the charge cannot switch on.
The battery capacity (Ah) is higher
than the charger's
The charging time will be abnormally
long. If possible, use a more powerful
charger
Choose the capacity indicated on your
battery.
The battery voltage does not rise,
the battery is damaged. Change the battery.
3
The battery is connected.
The charge indicator 1 does
not switch on. The battery
voltage indicators and bat-
tery capacity indicators are
switched on.
Polarities + and – are reversed Put the red clamp at the + the black
clamp at the -
Bad clamp connections. Clean the terminals and reconnect the
clamps.
The battery is deeply discharged. Use the « forced charge » mode (see
the procedure on the previous page)
The fuse is melted.
Disconnect the machine from the mains.
Remove the clamps from the battery.
Replace the fuse with regard to its size
(15 A for a Batium 7-12 7-24 or 30 A for
a Batium 15-12 and 15-24).
4
The indicator light «SOS
Recovery» (Batium 15.12
et 15.24) ashes after one
minute of charge.
The battery has suffered a deep
discharge over a long period, with
a start in sulfation. . The charge
continues but it is recommended to
switch to « SOS recovery ».
Disconnect the machine from the mains,
then the clamps. Activate the « SOS
Recovery » mode, see the previous
page.
5
SOS RECOVERY (Batium
15.12 / 15.24) : after 24
hours, the charge and end of
charge indicators are swit-
ched off.
Battery cannot be recovered Battery to be replaced
6
Forced charge : After pressing
the battery voltage button
during 5 seconds to start the
forced charge, the indicator
does not switch on.
Battery voltage < 0.5 V (± 0.3) Battery to be replaced
7When connecting to the
mains, no indicator switches
on Disconnect the Batium from the mains
during 10 sec., then reconnect it.