Haug EN SL MT Series User manual

Power Pack
EN SL
Version MT
Static Line
Operating instructions


Table of contents
1Notes on operating instructions ................................................................................. 5
1.1 Pictorial markings used................................................................................................. 5
2Safety............................................................................................................................ 6
2.1 Intended use.................................................................................................................. 6
2.2 Danger sources ............................................................................................................. 7
2.3 Installer qualifications.................................................................................................... 7
2.4 Operator qualifications .................................................................................................. 7
3Description of unit ....................................................................................................... 8
4Installation.................................................................................................................... 9
4.1 Important installation instructions................................................................................. 9
4.2 Setting up, connecting ................................................................................................ 10
5Application ................................................................................................................. 11
5.1 Putting into operation.................................................................................................. 11
6Remedy of defects..................................................................................................... 12
6.1 Troubleshooting .......................................................................................................... 13
7Maintenance and repairs........................................................................................... 14
7.1 Replacing fuse ............................................................................................................. 14
7.2 Accessories.................................................................................................................. 14
8Technical data............................................................................................................ 15
8.1 Characteristics and specification ................................................................................ 15
8.2 Supply voltage............................................................................................................. 15
8.3 Ambient conditions...................................................................................................... 16
8.4 Housing........................................................................................................................ 17
9Disposal ..................................................................................................................... 18

This page has been left intentionally blank.

Notes on operating instructions
Page 5
Keep in a safe place for future reference!
Types: EN SL (MT) 230 V 01.7906.005
EN SL (MT) 115 V 01.7907.005
EN SL (MT) 100 V 01.7907.055
1Notes on operating instructions
In these operating instructions, the power pack EN SL (MT) is also referred to
as "unit".
1.1 Pictorial markings used
In these operating instructions
NOT FOR USE by persons with pacemaker!
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
WARNING!
Only plug in/unplug coaxial connector when the unit is switched off!
CAUTION!
Important instructions!
On the unit
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
WARNING!
Only plug in/unplug coaxial connector when the unit is switched off!

Safety
Page 6
2Safety
_____________________________________________________________________________________
NOT FOR USE!
Persons wearing heart pacemakers must maintain a safety distance of more
than 50 cm from the ionizing unit!
Make sure that you read and observe the operating instructions of the
connected ionizing units!
_____________________________________________________________________________________
The unit is operationally safe, provided that it is operated in accordance with
its intended use.
In case of misuse, dangers may result:
- for life and limb of the operator,
- for the unit and other assets.
Also note Chapter 4.1 (Important installation notes, page 9).
2.1 Intended use
CAUTION!
Do not install or use the unit in areas subject to explosion hazards!
The unit is intended exclusively for the high-voltage supply of HAUG ionizing
units. It generates an alternating high tension of approx. 7 – 8 kV. It is
intended, in connection with an ionizing unit, for the removal of electrostatic
charges from, for example, glass, paper, plastics etc.
For reasons of safety, unauthorized conversions and modifications of the unit
are not permitted.
The installation and operating conditions indicated in these Operating
Instructions must be adhered to.

Safety
Page 7
2.2 Danger sources
____________________________________________________________________________________
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
WARNING!
Only plug in/unplug coaxial connector when the unit is switched off!
____________________________________________________________________________________
Defective high-voltage terminals and cables may lead to danger of electric
shocks. Shut down the unit immediately in case of visible damage and
suspected electrical defects.
2.3 Installer qualifications
The unit may be installed by trained electricians only. The above mentioned
person must have read the operating instructions and must follow the
instructions, notes and safety advice.
2.4 Operator qualifications
The unit may be maintained and put into operation by trained electricians
only or by authorized persons informed about the potential dangers. The
above mentioned persons must have read the operating instructions and
must follow the instructions, notes and safety advice.

Installation
Page 9
4Installation
The unit may be installed by trained electricians only. The above mentioned
person must have read the operating instructions and must follow the
instructions, notes and safety advice.
4.1 Important installation instructions
____________________________________________________________________________________
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
WARNING!
Only plug in/unplug coaxial connector when the unit is switched off!
____________________________________________________________________________________
The operation of the unit is not affected by the position in which it is installed.
However, we recommend installing the unit so that the high-voltage terminals
points downwards (to protect it from humidity, oil and dirt).
Do not place the unit on a surface generating or radiating heat. Avoid
installation positions exposed to direct sunlight.

Installation
Page 10
4.2 Setting up, connecting
_____________________________________________________________________________________
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
WARNING!
Only plug in/unplug coaxial connector when the unit is switched off!
_____________________________________________________________________________________
1. Before connecting always check that the unit is suitable for the local mains
voltage (the voltage is indicated on the name plate). Incorrect mains voltage
may result in damage to the unit.
2. Set up unit at the required site of usage (if required, attach using the enclosed
holders).
3. Ensure that the unit is switched off (for mains switch, refer to Figure 1, item 1,
page 8).
4. Connect ionizing units to high-voltage terminals.
5. Always connect unit to a socket with functioning ground wire. Always use the
supplied mains cable with its integrated ground wire.
6. Put unit into operation.

Application
Page 11
5Application
The unit may be put into operation by trained electricians only or by persons
instructed in the potential dangers. The above mentioned persons must have
read the operating instructions and must follow the instructions, notes and
safety advice.
The unit is intended exclusively for the high-voltage supply of HAUG ionizing
units. It generates an alternating high tension of approx. 7 – 8 kV. It is
intended, in connection with an ionizing unit, for the removal of electrostatic
charges from, for example, glass, paper, plastics etc.
5.1 Putting into operation
Preconditions:
The power pack and the ionizing unit must be connected correctly.
1. Switch on unit using the mains switch (refer to Figure 1, item 1, page 8).

Remedy of defects
Page 12
6Remedy of defects
_____________________________________________________________________________________
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
WARNING!
Only plug in/unplug coaxial connector when the unit is switched off!
_____________________________________________________________________________________
CAUTION!
The units include a thermal cut out.
If the unit overheats at the ionizing unit due to short circuiting, the thermal cut
out will switch off the unit. The power pack can only be put back into
operation once the short-circuit has been removed and the unit has cooled
down (approx. 15 minutes)!
Any remedy of defects must be carried out by trained electricians only. The
above mentioned person must have read the operating instructions and must
follow the instructions, notes and safety advice.
In case of defects regarding the power pack and the ionizing unit, please
check for correct installation and fusing first (for replacement, refer to
Chapter 7.1 page 14).

Remedy of defects
Page 13
6.1 Troubleshooting
Faults Measures
No ionization Check mains voltage
Check fuse (for replacement, refer to
Chapter 7.1, page 14)
Check connection
Clean ionizing unit
Check ionizing unit for damage. If damaged,
immediately shut down and secure against
restarting.
If this does not remedy the fault, please return the unit with the ionizing unit to
HAUG for checking (see reverse).

Maintenance and repairs
Page 14
7Maintenance and repairs
_____________________________________________________________________________________
WARNING!
High voltage!
Danger of fatal accidents!
Do not open unit!
_____________________________________________________________________________________
This unit does not include any parts which can be maintained or repaired by
the operator. HAUG only is authorized to repair or calibrate the unit.
Should the unit prove defective or if a defect is suspected, switch off unit
immediately and secure against subsequent reuse.
7.1 Replacing fuse
1. Switch off unit.
2. Determine and remove the cause for the blown fuse.
3. Detach the fuse holder using a screwdriver and lift out.
4. Replace fuse and reattach fuse holder.
Use the following fuses only:
Unit type Fuse
EN SL (MT) 100 / 115 V T 500 mA L 250; 5x20 mm
EN SL (MT) 230 V T 250 mA L 250; 5x20 mm
The unit type and the rated voltage are indicated on the nameplate.
Only use fuses of the type indicated.
7.2 Accessories
Article Order
number
One Point Ionizer 03.8510.200
Punkt – Elektrode XP 03.8513.200
Punkt – Elektrode XP (Set) 23.8513.100
U – Elektrode 05.8091.100
U – Elektrode (Set) 23.8091.100

Technical data
Page 15
8Technical data
8.1 Characteristics and specification
Reference temperature 23 °C
High-voltage terminals 2 HAUG High-voltage
terminals
High voltage U = approx. 7 - 8 kV
Short-circuit current Ik ≤5 mA
Cannot be used in pulsed mode
8.2 Supply voltage
CAUTION!
Always connect the PE conductor (green/yellow conductor) to the
protective earth of the mains!
Unit type Nominal
value
Operating
range
Frequency
range Power input
EN SL (MT) 100 VAC ±10 % 50 - 60 Hz Pmax = 40 VA
EN SL (MT) 115 VAC ±10 % 50 - 60 Hz Pmax = 40 VA
EN SL (MT) 230 VAC ±10 % 50 - 60 Hz Pmax = 40 VA

Technical data
Page 16
8.3 Ambient conditions
Ambient temperature:
Rated application range +5 °C to +45 °C
Extreme range for storage and transport -15 °C to +60 °C
Humidity:
Rated application range
Air pressure:
Rated application range 800 mbar to 1060 mbar
Vibrations:
Extreme range for storage and transport max. 1.5 g (10 to 55 Hz), 1 h
Shock max. 15 g in each direction
10
20
30
40
50
60
70
80
90
%RF
510 15 20 25 30 35 40 °C

Technical data
Page 17
8.4 Housing
Degree of protection IP 20
Protection class I
Overvoltage category II
Pollution severity 2
Connection to supply voltage Mains cable via socket for
non-heating apparatus
Dimensions:
Height approx. 170 mm
Width approx. 110 mm
Depth approx 100 mm
Weight: approx. 3,5 kg

Disposal
Page 18
9Disposal
Observe and maintain national and regional waste disposal regulations for
the disposal of the unit!


D – 0282
V 08-1
16.09.16
EN SL-MT v08-1gb.doc
made by
HAUG GmbH & Co.KG
Friedrich-List-Straße 18
D-70771 Leinfelden-Echterdingen
Telefon 07 11 / 94 98 - 0
Telefax 07 11 / 94 98 - 298
www.haug.de
E-Mail: info@haug .de
HAUG Bi el A G
Postfach
CH-2500 Biel / Bienne 6
Johann-Renfer-Strasse 60
CH-2500 Biel / Bienne 6
Telefon 0 32 / 3 44 96 96
Telefax 0 32 / 3 44 96 97
www.haug.de
E-Mail: info@haug-biel.ch
Table of contents
Other Haug Power Pack manuals

Haug
Haug EN 8 SLC MT User manual

Haug
Haug EN SL SLC MT User manual

Haug
Haug METTLER TOLEDO EN Series User manual

Haug
Haug Static Line EN SL User manual

Haug
Haug EN SL LC User manual

Haug
Haug Multistat Ex SDN User manual

Haug
Haug EN 15 Ex User manual

Haug
Haug EN 8 LC User manual

Haug
Haug Multistat S User manual

Haug
Haug 01.7835.300 User manual