manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Huawei
  6. •
  7. Server
  8. •
  9. Huawei TaiShan 100 User manual

Huawei TaiShan 100 User manual

1 2 3
Taishan 100 Server Quick Installation Guide
(Model 2280)
Document Issue: 05 (2020-07-13) BOM: 31509689
Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd. 2020 All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and
recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any
kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, e
x
press or implied.
Symbol
Description
Indicates a hazard with a high level of risk which, if not avoided, will
result in death or serious injury.
Indicates a hazard with a medium level of risk which, if not avoided,
could result in death or serious injury.
Indicates a hazard with a low level of risk which, if not avoided, could
result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, could
result in equipment damage, data loss, performance deterioration, or
unanticipated results.
NOTICE is used to address practices not related to personal injury.
Supplements the important information in the main text.
NOTE is used to address information not related to personal injury,
equipment damage, and environment deterioration.
1 Specifications
TaiShan 2280 server (TaiShan 2280 for short) is a high-performance server, applying to
high-performance computing (HPC), databases, web servers, virtualization, basic enterprise
applications, and telecom service applications.
.
Environmental specifications of the TaiShan 2280:
Item
Specification
Temperature
⚫Operating range: 5°C to 40°C (41°F to 104°F )
⚫Storage range: –40°C to +65°C (–40ºF to +149ºF)
⚫Long-term storage temperature: 21°C to 27°C (69.8°F to
80.6°F)
⚫Maximum temperature change rate: 20°C/h (36°F/h)
If a single fan fails, the node performance may be affected or a
temperature alarm may be generated. After the faulty fan is
replaced, the fault can be rectified.
Relative humidity
(RH, non-condensing)
⚫Operating range: 8% to 90%
⚫Storage range: 5% to 95%
⚫Long-term storage humidity: 30% to 69%
⚫Maximum change rate: 20%/h
Maximum altitude
3050 m (10000 ft.)
ASHRAE 2015 compliant:
⚫ASHRAE Class A1 and A2 compliant: For altitudes above 900
m (2952.72 ft.), the highest operating temperature decreases
by 1°C (1.8°F ) for every increase of 300 m (984.24 ft.) in
altitude.
⚫ASHRAE Class A3 compliant: For altitudes above 900 m
(2952.72 ft.), the highest operating temperature decreases by
1°C (1.8°F ) for every increase of 175 m (574.15 ft.) in
altitude.
⚫ASHRAE Class A4 compliant: For altitudes above 900 m
(2952.72 ft.), the highest operating temperature decreases by
1°C (1.8°F ) for every increase of 125 m (410.10 ft.) in
altitude.
2 Tools
ESD gloves Floating nut mounting bar Phillips screwdriver Ladder
3 Installation
⚫Exercise caution when using tools.
⚫If the installation position of the device is higher than the shoulders of the installation
personnel, use a vehicle such as a lift to facilitate installation. Prevent the equipment from
falling down and causing personal injury or damage to the equipment. When a ladder is
used, ensure that another person holds the ladder steady to prevent accidents.
⚫Wear ESD gloves and remove conductive objects, such as jewelry and watches.
⚫At least two persons are required to move the chassis. When moving a chassis, keep your
back straight and move smoothly to avoid any injury.
⚫Do not use mounting ears as the holding points when moving the server. Otherwise, the
server may be damaged or slipped.
1. Hold the bottom of the server with both hands, lift the server from both sides, and place the
server on the guide rails.
2. Push the server into the cabinet. See (1).
3. Align the mounting ears on both sides of the server with the mounting bars and tighten the
captive screws on the mounting ears to secure the server. See (2).
4 Power-On
The TaiShan 2280 does not provide a separate ground port. It uses power cables for ground
connection. The equipment is powered by high-voltage power sources. Direct or indirect contact
(especially through damp objects) with high-voltage power sources may result in serious injury
or death.
1. Connect the VGA cable , USB cable , Network cable , management network port
cable, and serial port cable as required.
2. Connect cables to the power sockets.
4 5
3. Turn on the power switch in the cabinet.
The recommended current specification for the external power circuit breaker connected to
the
server is as follows:
⚫AC power supply: 32 A
⚫DC power supply: 63 A
4. Power on the server.
The power-on methods of the server vary according to the following scenarios:
⚫The power supply units (PSUs) are properly installed but not powered on.
Connect the external power supply to the PSUs. Then the server will power on with the
PSUs.
The default value of System State Upon Power Supply is Power On, which indicates
that the server automatically powers on after power is supplied to the PSUs. To change
the value of System State Upon Power Supply, log in to the iBMC WebUI and choose
Power > Power Control.
⚫The PSUs are installed properly and powered on. The server is in the standby state (the
power button/indicator is steady yellow).
−Press the power button/indicator to power on the server.
−Power on the server using the iBMC CLI.
Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter yor
Yto power on the server.
−Power on the server using the iBMC WebUI.
Log in to the iBMC WebUI, choose Power > Power Control, click Power On, and click
OK to power on the server.
−Power on the server using the remote virtual console.
Log in to the remote virtual console. On the KVM screen, click or on the
toolbar, select Power On, and click Yes to power on the server.
5. Check the status of the indicators.
⚫If the power indicator is steady green, the PSUs are powered on.
⚫If the power button/indicator is steady green, the server is powered on.
5 Appendix: Hazardous Substance Statement for
Electronic and Electrical Products
Part
Hazardous Substances
Cd
Pb
Hg
Cr (VI)
PBBs
PBDEs
PCBA
◯
×
◯
◯
◯
◯
Cables
◯
×
◯
◯
◯
◯
Accessories
◯
×
◯
◯
◯
◯
Equipment
◯
×
◯
◯
◯
◯
Batteries*
◯
×
◯
◯
◯
◯
This statement for electronic and electrical products complies with SJ/T 11364.
◯: all homogenous part materials under GB/T 26572 hazardous substance limit
×: at least one homogenous material exceeds GB/T 26572 hazardous substance limit
*: when in use by the product

This manual suits for next models

1

Other Huawei Server manuals

Huawei ViewPoint 9000 Series User manual

Huawei

Huawei ViewPoint 9000 Series User manual

Huawei E9000 User manual

Huawei

Huawei E9000 User manual

Huawei MicroDC3000H User manual

Huawei

Huawei MicroDC3000H User manual

Huawei 2288H V5 User manual

Huawei

Huawei 2288H V5 User manual

Huawei BTS3900C Guide

Huawei

Huawei BTS3900C Guide

Huawei Tecal RH5485 User manual

Huawei

Huawei Tecal RH5485 User manual

Huawei FusionServer Pro 2288X V5 Quick reference guide

Huawei

Huawei FusionServer Pro 2288X V5 Quick reference guide

Huawei E9000 Operating instructions

Huawei

Huawei E9000 Operating instructions

Huawei PDU8000 Series User manual

Huawei

Huawei PDU8000 Series User manual

Huawei FusionServer Pro 2288H V5 User manual

Huawei

Huawei FusionServer Pro 2288H V5 User manual

Huawei EGW2100 V100R001C02 User manual

Huawei

Huawei EGW2100 V100R001C02 User manual

Huawei 5288 V5 User manual

Huawei

Huawei 5288 V5 User manual

Huawei Tecal RH5485 User manual

Huawei

Huawei Tecal RH5485 User manual

Huawei G5500 User manual

Huawei

Huawei G5500 User manual

Huawei RH2488 V2 Server BMC User manual

Huawei

Huawei RH2488 V2 Server BMC User manual

Huawei FusionModule2000 V500R003C10 User manual

Huawei

Huawei FusionModule2000 V500R003C10 User manual

Huawei IDS2000 Dual-Row Aisle Containment User manual

Huawei

Huawei IDS2000 Dual-Row Aisle Containment User manual

Huawei X6000 User manual

Huawei

Huawei X6000 User manual

Huawei UPS5000-E-****-FM series User manual

Huawei

Huawei UPS5000-E-****-FM series User manual

Huawei U-SYS MRS6100 User manual

Huawei

Huawei U-SYS MRS6100 User manual

Huawei FusionModule2000 V500R003C10 Operating manual

Huawei

Huawei FusionModule2000 V500R003C10 Operating manual

Huawei TP48200A-D17B3 User manual

Huawei

Huawei TP48200A-D17B3 User manual

Huawei FusionModule5000 Technical specifications

Huawei

Huawei FusionModule5000 Technical specifications

Huawei FusionServer Pro 1288X V5 Quick reference guide

Huawei

Huawei FusionServer Pro 1288X V5 Quick reference guide

Popular Server manuals by other brands

Lenovo ThinkServer TD340 User guide and hardware maintenance manual

Lenovo

Lenovo ThinkServer TD340 User guide and hardware maintenance manual

NEC Express320F Brochure & specs

NEC

NEC Express320F Brochure & specs

Dell PowerEdge R320 Getting started guide

Dell

Dell PowerEdge R320 Getting started guide

Gigabyte E243-EG0-AAF1 user manual

Gigabyte

Gigabyte E243-EG0-AAF1 user manual

HP Integrity rx6600 Hardware quick start guide

HP

HP Integrity rx6600 Hardware quick start guide

Rasilient ApplianceStor 90 user manual

Rasilient

Rasilient ApplianceStor 90 user manual

Opengear cm4008 quick start guide

Opengear

Opengear cm4008 quick start guide

Compaq TruCluster Server AA-RHGWB-TE manual 

Compaq

Compaq TruCluster Server AA-RHGWB-TE manual 

Overland Storage SnapServer Administrator's guide

Overland Storage

Overland Storage SnapServer Administrator's guide

Inspur NF5260FM6 user manual

Inspur

Inspur NF5260FM6 user manual

Supermicro SuperServer 5039C-I user manual

Supermicro

Supermicro SuperServer 5039C-I user manual

Wahsega Carina Event Manager Lite user guide

Wahsega

Wahsega Carina Event Manager Lite user guide

Samsung SPE-400 user manual

Samsung

Samsung SPE-400 user manual

Dell PowerEdge 6850 Information update

Dell

Dell PowerEdge 6850 Information update

TYAN GC68-B8036 Service engineer's manual

TYAN

TYAN GC68-B8036 Service engineer's manual

Linear AM-SEK user manual

Linear

Linear AM-SEK user manual

Lenovo ThinkServer RD230 manual

Lenovo

Lenovo ThinkServer RD230 manual

IBM 884872U - eServer 326 - 8848 user guide

IBM

IBM 884872U - eServer 326 - 8848 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.