Hydra Zodiac DLB User manual

Zodiac DLB
Dynamic Load Balancing
INSTALLATION MANUAL
DLB-V0001-23/01/2023

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
2
INTRODUCTION
DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY
All information, specications and illustrations in this manual are based on the latest information available at
the time of printing, images and illustrations depicted in the manual may differ slightly from actual products.
Hydra EVC Ltd reserves the right to make changes at any time without prior notice. Although this manual
has been carefully checked, it does not guarantee the completeness and correctness of the contents of the
manual, including but not limited to product specications, functions, illustrations, etc.
Before operating or maintaining this product, please read this manual carefully and pay special attention to
safety warnings and precautions.
Note: This document is intended to guide professional electricians and installers through the use and on-site
installation of the Hydra home dynamic load balancer.
If you use the equipment in a manner other than described in this manual or other related documents, death,
injury and property damage could occur.
The home load balancer can maintain the dynamic balance of the total household current, to ensure the safety
of electricity consumption, and to avoid the overload of household electricity when the chargpoint is charging.
A home load balancer consists of a transmitter and a receiver. The transmitter needs to be installed at the main
incoming line of the household power supply to transmit the sensed current data to the receiver. The receiving
end is located inside the household AC chargepoint (the chargepoint needs to be purchased additionally), and
receives the data from the transmitting end.
Size 90mmX90mmX38mm
Support voltage/current 1 Phase:230V±10% 50/60Hz,100A
3 Phase:400V±10& 50/60Hz,100A(per phase)
Interfacet Household line transformer interface 3
Indicator light LED 2RED+GREEN
Power supply CT induction power supply
Transfer method Wireless transmission
Button Pair key 1
IP IP31
Operating temperature -20 °C to +40 °C
Storage temperature -40 °C to +70 °C
Working humidity 5%-95% No-condensing
Working altitude 2000 m
Installation method Back panel + guide rail / buckle
Transformer installation method Open lock
Shell material ABS

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
3
INTRODUCTION
THE TRANSMITTER
THE RECEIVER (THE ZODIAC)
1
4
7
2
5
8
3
6
9
1Indicator light
2Pairing button
3Rail buckle
4Guide antenna interface
5RJ45 interface
6DIP switch
7Rubber stopper
8CT interface
9Reserved interface
Pairing button
LED Indicator light
Socket

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
4
INSTALLATION
This device can only be used indoors or inside a cabinet, not outdoors. When selecting an installation site for
the device, consider the environmental conditions listed in the table below.
Equipment recommended installation environment table
Ambient temperature -20°C~+40°C
Altitude ≤2000m
Humidity 5%~95%RH
Dust ≤1mg/m3
Corrosive substances Free from pollutants such as salt, acid, smoke, etc.
Shock ≤1.5mm/s
Damp Rainproof, protection above IPX4
Fire protection No ammables nearby

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
5
INSTALLATION
1Install the DIN rail on the wall
2Connect the transformer (CT) and antenna
4Connect the transformer (CT) to the main power line of the household, connect the single phase to the L
phase line, and connect the three phases to the L1, L2, and L3 phase
5Please refer to the HYDRA ZODIAC installation manual for installation instructions
(download from www.hydraev.co.uk/support)
3Connect the transformer (CT) and antenna
CT
Antenna
Single Phase Three Phase
If you are installing a
three-phase supply insert
the CT connectors into the
three sockets at the front
If connecting a single phase
CT insert connector into this
position only.

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
6
PAIRING
Wireless
Pairing
1Quickly click the
pairing button 3 times
3Quickly click the
button in and out 3 times
(a total of 6 presses of
the button)
2The indicator
light ashes red
and green
5The green
light will ash
4The indicator light
ashes red, green and
blue alternately
6The Blue light
remains illuminated

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
7
SETTING UP THE APP
AFTER THE PAIRING IS COMPLETED
1Please scan the corresponding QR code to download the HYDRA HOME app and complete the registration.
ANDROID IPHONE
2Pair the Hydra Home App to the Zodiac Chargepoint and set up according to instructions in the app manual:
www.hydraev.co.uk/support
Note: Professionals must conrm the maximum load capacity of the family and set the corresponding value.
When the household power supply is single-phase power supply, only one transformer (CT) is used, and the
household load balancer starts to work when the total electricity consumption current of the household needs
to exceed 20A. When the current is less than 20A, the home load balancer remains off.
When the household power supply is three-phase power supply, three transformers (CT) are used, and the
household load balancer starts to work when the total household power current needs to exceed 10A. When
the current is less than 10A, the home load balancer remains off.
Tap the icon in the
upper left corner
Tap on Household
Settings
Set the number of
power phases and
maximum current
Tap conrm button

✆
01268 205 121
| www.hydraev.co.uk | sales@hydraev.co.uk
8
TROUBLESHOOTING
Fault state RECOMMENDED TREATMENT
Equalizer light is off
Check whether the front-end charging transformer is good or
bad and whether the connection is correct; check whether the
input current reaches the minimum current value required for
work.
The equalizer light is on, but there is no
communication
Check whether the pairing is successful; check whether the
distance between the transmitter and receiver is too far or there
are many obstacles; check whether the charging pile is powered
on; check whether the APP is set correctly.
Still tripping after using equalizer Check whether the maximum current set on the APP is correct.
Unable to pair
Check whether the pairing operation is correct; check whether
the transmitter and receiver are in pairing mode; check whether
the distance between the transmitter and receiver is too far or
there are many obstacles.
Other problems Please contact our after-sales service.

HYDRA EVC Ltd
Telephone: 01268 205 121
Email: sales@hydraev.co.uk
Unit 11, Totman Close, Rayleigh, Essex SS6 7UZ
DLB-V0001-23/01/2023