UC 0
USAGE CLASS
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
WT 0
GATE WEIGHT (LB)
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
LN 0
GATE LENGTH (FT)
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
SH 0
GATE HANDING
Page 8 D0324 Rev D SwingSmart DC Quick Start Steps © 2013 www.hysecurity.com
turn On POWer & COmPlete the Set uP
SELECTIONS
0 – No Usage Class set.
1 – Single Family residential up to four units.
2 – Multi-family, hotel, etc.
3 – Industrial use, not for general public.
4 – Guarded and monitored facility not for
general public.
The USAGE CLASS menu display appears the rst time power is
applied. Four sequential displays present information which must be
congured before SwingSmart will function.
To edit
the MENU
To navigate through
SELECTIONS
To choose what is
on the display
To navigate
between menus
Press SELECT.
Two top
characters blink.
Press NEXT.
Continue pressing NEXT
to view all selections.
Press SELECT.
Blinking characters
become static.
Press NEXT or PREV.
Advance – press NEXT
Previous – press PREV
Emergency Stop
Button (A hole in
the cover provides
accessibility.
Turn ON power
at the main
circuit breaker
and toggle
both power
switches ON.
SELECTIONS
0 – No handing set. Gate will not move until
handing is set.
Looking at the gate from the secure, operator
side, choose:
R – If the operator is on your right.
L – If the operator is on your left.
SELECTIONS
0 – Not set.
1 – Gate weight: 0 to 300lbs (0 to 136kg)
2 – Gate weight: 301 to 600lbs (136 to 272kg)
3 – Gate weight: 601 to 800lbs (272 to 363kg)
4 – Gate weight: 801 to 1300lbs (363 to 590kg)
SELECTIONS
0 – Not set.
1 – Gate length: 0 to 8ft (0 to 3m)
2 – Gate length: 8 to 12ft (3 to 4m)
3 – Gate length: 12 to 16ft (4 to 5m)
4 – Gate length: 16 to 20ft (5 to 6m)
An audible beep occurs when the initial setup
is complete
Note: One of three gate status displays will
appear depending on the gate's position.
GATE OPEN
GATE CLOSED
GATE STOP
COmPlete the inStall
Refer to the installation manual
to congure User and Installer
Menu options such as gate speed,
IES sensitivity, Close Timer, relay
functionality, etc.
teSt the gate
Test cycle the gate operator by
pressing the OPEN and CLOSE
buttons. Make sure the gate travels
to full open and close positions.
Readjust the limit cams as required.
When the gate and operator are
functioning properly, replace the
operator's covers and secure the
latches.
Review the Important Safety
Instructions with the end use/
property owner on the proper use
of the gate system.