© 2018 United Technologies Corporation. P/N 1073513A• REV 00.00 • ISS 4JUL18
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
ACL805SUW-BS - Biometric Swipe capacitive
Keypad Wiegand Reader - Installation Manual
Description / Operation
ACL805SUW-BS is a Wiegand biometric reader for outdoors
access control applications. It offers storage up to 100
fingerprints, programmable Wiegand output (24 to 80 bits) and
selectable PIN code length.
Configuration of the readers and fingerprint enrollment is done
through PC software.
When used with third party controllers, the connection between
the Biometric readers and the PC is done through ACL800FL-
CONV-W converter (RS485 to TCP/IP). Only one converter is
needed per system (one converter for 1, 2, 3...30, 31 biometric
readers).
The tamper switch output can trigger the alarm system, if an
attempt is made to open or remove the unit from the wall.
The sensor incorporates dedicated sensing hardware to
facilitate the detection of “spoofing” attacks based on fake
fingers. This data is embedded into the image data stream,
and is processed on the processor. The system is capable of
detecting and defeating well-known fake finger mechanisms,
such as molded “gummy” fingers.
The coating on the surface of the swipe chip sensor provides
protection from scratching and abrasion due to normal contact
with fingertips and any incidental contact with fingernails.
Specifications
Finger, PIN code, finger or/and PIN code
Wiegand 24 to 80 bits; default: Wiegand 26bit
Via ACL800 BioManager software
1:1000 identification
time
970 msec, including feature extraction time
On the reader or from the USB desktop reader
-20 to +50°C noncondensing
Mounting
Figure 1: Mounting instructions
If the biometric reader is installed and used outdoor, the reader
MUST be fitted with a cover in order to protect the sensor from
direct rainfall. The operating temperature of the product is
between -15 to + 50ºC. If the reader is installed in an
environment where the temperature can drop below -10ºC
or/and if the sensor could only be exposed to direct sunlight, it
is strongly recommended to install the reader inside a third
party sealed wall mount box (fitted with additional heater if very
low temperature) to keep a constant sensor level performance.