iRest BRILLACTIQ A665 User manual

Instrukcja obsługi PL
EN
User manual
MASSAGE CHAIR
iREST BRILLACTIQ (A665)

01
EN
CONTENTS
Maintain
47
Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before use
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Place massage chair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
02-04
05-06
07-08
09-10
11-16
17-46
46
Operation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Massage close . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Usage method
48
49
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important
Thanks for purchasing this product. Please read this manual instruction carefully
in order to know how to use this product correctly before operation. Please pay more
attention to some important safety warning and keep this manual book properly
for future use.
Note: Our company reserves the right to change and explain the design of the
product. If there is some difference between the product function in market
circulation and the description in the manual, it is a normal update of the product,
and our company will not inform you otherwise. The specific product function and
color shall prevail in kind.

02
Safety and maintenance
EN
Indicates that serious injury or death may result from
improper use.
Please pay attention to the symbol before each safety item.
Forbidden
Warning
Please read all relevant instructions carefully before use.
The notes marked here will help you to use the product safely and correctly.
In order to clearly indicate the extent of harm and damage, precautions are
divided into "Warning" and "Caution" that may be caused by incorrect use.
Both of them are important for safety and must be followed.
Caution
The device is not intended for use by persons (including children)
with physical disabilities, sensory or neurological impairments or
who lack experience and common sense, unless they are
supervised and instructed in the use of the device by those
responsible for their safety. Children must be supervised to ensure
they do not play with instruments.
Patients with osteoporosis.
Patients with heart disease or wearing electronic medical devices
such as a pacemaker.
People who have a fever.
Pregnant women or women on their menstrual period.
Patients who are injured or have a skin disease.
When unsupervised, any children are under the age of 14 and
those unconscious are not allowed to use this product.
People who are told by their physicians to have rest or who feel
unwell.
People whose bodies are wet are forbidden to use this product.
This product has a hot surface. Persons insensitive to heat must
pay attention when using this product.
If the supply cord is damaged, to avoid danger, it must be replaced
by a professional from the manufacturer, its maintenance
department or similar department
Indicates that misuse may cause minor injury or property
damage.
Absolute prohibition
The following populations should not use this product
Forbidden

03
Safety and maintenance
EN
Important safety warnings
Do not allow children to touch any movable part of this product.
Use the well-grounded power supply unit suitable for this product.
Pull out the plug after use or before cleaning to avoid any physical
injury or damage to the product.
Operate this product as instructed in this manual.
Do not use any parts or accessories which are not recommended.
Do not use this product outdoors.
Please read the Operation Instructions carefully before operation.
Never use this product for any other purpose not listed herein.
20 minutes of usage each time is recommended.
Do not use this product if the cover or leather is broken or
damaged.
Do not drop anything into this product.
Never fall asleep while using this product.
Do not use this product if you are drunk or feel unwell.
Do not use this product within one hour after a meal.
Do not use this product with excessive force to avoid any injury.
Storage conditions
Storage room temperature: 5 °C to 40 °C.
Relative humidity (RH) between 20% and 80%; free of corrosive
gases, and a well-ventilated room.
Warnings
Check whether voltage is consistent with the specification of this
product.
Never insert or pull out the plug with a wet hand.
Do not let water flow into this product to avoid electric shock or
cause damage to this product.
Do not pull the power cord when plugging or unplugging it. Rough
handling is forbidden.
Do not damage the wire or modify the circuit of this product.
Do not clean live parts of this product with a wet cloth such as a
power switch and plug.
Be away from this product in case of power failure to avoid any
injury if power is restored suddenly.
Stop using this product at once while it works abnormal, and
consult your local supplier.
Stop using this product if you feel unwell, and consult your health
care practitioner.
Safety precautions
Caution
Caution

04
Use safety warning
EN
This product should be maintained by the service center designated
by the manufacturer only. No user should disassemble or maintain it
without permission.
Do not forget to turn off the main power switch after usage.
Do not use this product if the power socket becomes loose.
If this product will be left unused for a long period of time, it is
necessary to roll up the power cord of this product and store this
product in a dry and dust-free environment.
Do not store this product at a high temperature or near open flame.
Avoid prolonged exposure to direct sunshine.
Please clean this product with dry cloth. Never use thinner, benzene
or alcohol.
The mechanical components of this product are specially designed
and manufactured, so no special maintenance is needed.
Do not use a sharp object to stab at this product.
Do not roll or pull this product on any uneven ground. Instead, it
should be lifted before moving.
Please use this product intermittently. Do not keep it working
continuously for a long period of time.
Product service and maintenance
Operating environment
Do not use this product in a very moist environment such as the
bathroom.
Stop using this product immediately when the ambient temperature
changes sharply.
Do not use this product in any heavily-dusty or caustic environment.
Do not use this product in a small space or a place without good
ventilation.
If the motor sounds during operation of this product, this is the
normal operation sound.
If the controller cannot work normally, check whether the plug and
the power socket are connected reliably, and whether the power
switch is turned on.
If the rated working time is over, this product will automatically
activate the power -off button; If this product keeps operating for
a long period of time, the temperature protector will stop this product
automatically. The product can be used again after half an hour.
Solutions to ordinary malfunctions
Caution
Caution
Caution

05
Installation parts
EN
Armrest installation instructions
1. Insert the wire harness inserts and air pipe on the side of the steel frame into the
corresponding positions on the armrest (Figure 1).
2. Lift up the armrest with the air pipe and wire inserted, and hang all the hooks on
the armrest on both sides of the steel frame (Figure 1).
Figure 1
Figure 2 Figure 3
3. Put the roller at the rear end of the armrest on the surface of the armrest fixing part
(Figure 2), and put down the armrest backwards, then push the armrest backwards,
and lock it with 2 pieces M5 screws (Figure 3);
Calf installation instructions
Figure 1 Figure 2
1. Insert the wire of the calf and the air pipe into the sockets on the front end of the
steel frame assembly (Figure 1).
2. After the wire docking is completed, open the calf fixing covers on both sides of
the steel frame assembly (Figure 2).

06
EN
3. Lift the calf into the notch, close the fixing covers, and secure it in place with 2
pieces M5 screws (Figure 3).
Figure 3
Touchscreen hand control bracket installation instructions
1. Align the bracket with the hole at the front of the armrest (right) and fasten it with
M5 screws (Figure 1).
2. Align the bracket decorative piece with the bracket and press down along the
bracket rods all the way down (Figure 2).
Figure 1 Figure 2
3. After the entire bracket is installed, shake the bracket lightly to confirm whether it is
firmly installed; the bracket installation is complete (Figure 3).
Figure 3
Installation parts

07
Place massage chair
EN
10cm
Make sure there is enough
space for the massage chair can
be tilted at least 10 cm.
Do not expose the massage chair
directly to high temperature
environment due to sunlight(such
as: in front of heating equipment),
and place it to where can avoid
high temperature and direct
sunlight. It is recommended to lay
a soft cushion for long-term use in
a designated location. When laying
the cushion, the size of the
cushion should be enough to cover
Keep the range where the machine
touches the floor and the range
where your feet touch the floor.
Installation placement
CAUTION
CAUTION
Require team work to lift and move
the chair to avoid injury.
1. Please lift the massage chair to
move it on vulnerable ground such as
wooden floor.
2. When moving on a similar wooden
floor, it is recommended to lift it.
Avoid damage to the casters. When
the floor is lifted and moved to the
designated position, be careful to
keep your hands out of the way to
avoid injury, and be careful of your
feet being crushed. Do not let go of
the unit until the unit is completely
flat, the floor may be damaged,
therefore, it is recommended to
place mats, etc. on the floor.
Product lift instruction

08
EN
45
Place massage chair
How to disassemble and use headrest cushion and backrest cushion
Move method
Using a headrest cushion can reduce
the intensity of kneading massage on
the neck and shoulders, and you can
decide whether to use a headrest
cushion according to your needs
(recommended to use a headrest
cushion). The backrest cushion and the
backrest are connected by a zipper (1),
and the headrest cushion and the
backrest cushion are connected by
a zipper (2).
12
Zipper Zipper
Use the rear casters to move the
massage chair.Move the chair by tilting it
down and backward about 45° as shown
in the diagram.
NOTE: Excessive force to title will cause
the chair to tip over completely and
product damage.
1. Before moving, please shut down the
machine properly to reset the whole
machine, and then cut off the power.
2. Please keep the chair vacant when
moving. (People, pets or clutter will not
be able to stay on the chair.)
3. When moving, do not cross a drop
barrier higher than 2mm or a gap
greater than 5mm.
4. When using casters to move this
product, single continuous movement
is not supported; if the distance exceeds
50 meters, please make this product
move slowly and evenly.
CAUTION
CAUTION

09
EN
Before use
CAUTION
Check around
Make sure there are no foreign objects in the
gaps of the machine
Make sure that there are no people, pets and
other objects around the unit.
CAUTION
Before massaging, make sure that
no foreign objects are caught in the
legs, feet, etc.
Under no circumstances allow
hands, feet, and head to penetrate
into the area between the lower leg
mechanism and main body, or the
area between the armrest and the capsule.
Under no circumstances should
hands, feet, or head sink under the
fabric or leather covering of the
massage area.

10
EN
POWER INPUT
ON /OF F
FUSE: T6.3AL 250V
POWER INPUT
ON/ OFF
FUSE: T6.3AL 250V
Before use
Warn
Please check the power cord and plug for damage before use.
Please supply power to this product in accordance with the working
power requirements of this product's calibration.
It is strictly forbidden to use a power supply other than the nominal
power supply of this product.
It is strictly forbidden to connect various power conversion devices
without authorization to supply power to this product.
Turn on the power
Caution
1 2 3
Plug in power cord Schematic diagram
of power on Turn on the power
switch ("I" position)

11
Product structure
EN
Description of Components
1
2
3
4
5
6
7
8
9
10
11
12
1. Head cushion
2. Manual controller
3. Arm air pressure
4. Leg massage components
5. Space capsule
6. Shoulder air pressure
7. Shawl back cushion
8. Armrest shortcut keys
9. Health Detection System
10. Armrest
11. Atmosphere lamp
12. Side cover

12
EN
Schematic view of functional distribution
1
2
3
4
5
6
7
8
9
Product structure
1. Shoulder
·Airbag massage
2. Arm
·Manual bracket
·Mobile phone placement slot
·USB charging port
·Wireless charger
3. Hand
·Airbag massage
4. Leg
·Airbag massage
5. Sole
·Roller massage
6. 4D digital audio on both sides of the head
·Music player
·Built-in voice control microphone
7. Head and neck to seat
·Manipulator massage
8. Shoulder, back & waist, abdomen
·Heating function
9. Leg
·Airbag massage
·Kneading massage
8a
8a. Magnetoteraphy

EN
13
How to use the shawl
Heating area
Heating area
Schematic diagram
of use on back and waist Schematic diagram
of use on shoulder and abdomen
It is provided with a unique shawl assembly, with innovative heating functions on
the shoulder, back, waist and abdomen and heating with graphene. Users can
place the shawl at different massage positions according to massage
requirements. When the shawl assembly is placed at the shoulder position, it will
heat the acupoints such as Bingfeng, Tianzong, Yunmen and Qihu around the
shoulder and clavicle by graphene heating, effectively relieving symptoms such
as scapulohumeral periarthritis and cough, and removing cold and moisture from
shoulder joints.
When the shawl assembly is placed on the abdomen and back (dual-purpose),
through graphene heating, it plays the role of dispelling cold and relieving pain,
warming channels and removing blood stasis in the back and abdomen,
distributing Qi and blood of the back and abdomen meridian, alleviating the
symptoms such as irregular menstruation and dysmenorrhea for women, relieving
low back pain and kidney discomfort, warming intestines and stomach and
clearing intestinal cold, with a good effect on some people with deficiency of qi and
deficiency of spleen and stomach.
Product structure
·
·

EN
14
12
11 10
09
08
07
060504030201
13
14
15
16
4D
Speed
Full
4D I
Area
Shoulder
Air intensity
00:30
Home
Auto
Manual
Angle
Settings
Power Pause
Speed
4D
Manual
Air intensity
Back heat Roll Calf Voice
Gentle
Soothing
Strong
Width
Width
Main information interface
I. Remote controller keys instruction
01. On/off touch key: Enable or disable the Massage Chair function.
02. Pause key: Pause the massage or exit from pause massage.
03. Back heating key: Enable or disable the Back Heating function.
04. Sole roller key: Enable or disable the Sole Roller function.
05. Calf kneading key: Enable or disable the Calf Kneading function.
06. Voice control key: Wake up voice assistant.
07. Intensity selection key: Select one from different automatic massage intensities.
08. Button ON/OFF key: Turn on or off the massage chair.
09. Air pressure intensity key: Adjust the air pressure.
10. Massage area key: The function of selecting massage position.
11. Shoulder position adjustment key: Regulate shoulder position and confirm
massage criterion.
12. Current status key: Enter to view current massage chair status.
13. Auto key: Enter the automatic massage program selection function.
14. Manual key: Enter the manual setting massage function.
15. Angle button: Enter the angle adjustment interface to select the sitting posture angle.
16. Settings key: Enter the setting menu interface.
Product structure

15
EN
1920
18
212223
17
24
25
26
4D
Speed
Full
4D I
Area
Shoulder
Air intensity
00:30
Power Pause
Speed
4D
Manual
Air intensity
Back heat Roll Calf Voice
Gentle
Soothing
Strong
Width
Width
Customise
Health
Memory
17. Massage technique selection key: Select the massage technique.
18. Massage width key: Adjust the massage width.
19. Status display bar key: Display the massage program status information.
20. Air massage selection key: Select air position.
21. Time adjustment menu key: Adjust the massage time.
22. Massage speed key: Adjust the massage speed.
23. 4D intensity key: Adjust 4D intensity.
24. Health detection key: Enter the health detection interface.
25. Custom key: Enter the custom interface.
26. Storage key: Enter the storage interface.
Product structure

16
EN
START
STOP
AUTO
4D
II. Description of armrest shortcut keys
1 2 3 4
567
1. Switch
• Turn on or off the massage chair.
2. 4D+ key
• Press this key to increase the 4D intensity, up to 5 levels.
• Lift this key up, the 4D intensity is reduced, and the lowest is 1 level.
3. Calf retractable key
• Press and hold the button to extend the foot slowly, release it to stop the foot
extension.
• Lift the button to shorten the foot slowly, release it to stop the foot shortening.
4. Zero Gravity key
• Short press this key to automatically adjust the zero gravity angle, two levels can
be adjusted. Press and hold for 1 second, the angle returns to the initial angle,
the calf is lowered to the lowest position, and the backrest is raised to the highest
position.
5. Linkage up and down key
• Press and hold this button, the backrest rises slowly, and the leg rest slowly
descends, release it to stop the backrest rising and the leg rest descending, and
the leg rest will automatically detect the foot length.
• Lift the button and the backrest will slowly descend, and the leg rest will slowly
rise. Release it to stop the backrest descending and the leg rest ascending.
The leg rest will automatically detect the foot length.
6. Leg rest up and down key
• Press and hold the button to lower the leg rest slowly, release it to stop the
lowering, the leg rest will automatically detect the foot length.
• Lift the button to raise the leg rest slowly, release it to stop the leg rest rising,
the leg rest will automatically detect the foot length.
7. Voice control key
• Press to turn on or off the voice assistant function, and short press to wake up the
voice assistant.
Product structure

17
Operation Instructions
EN
Auto Lying Down
Power
Skip
III. Start massage
1. Press the remote controller side button on/off key or long press the armrest
on/off key.
2. After the system is started, select the massage intensity by clicking on any one of
the Gentle , Comfort or Strong keys on the remote controller to turn
on the massage chair and enter the lying state. If it is not selected within 5 minutes,
the massage chair will turn off automatically.
3. For automatic angular adjustment, select the automatic program, then the massage
chair will be automatically adjusted to Zero Gravity angle, and wait until its adjustment
is completed. To skip a step, press the skip key to go directly to the next step.
Skip
Select level
Gentle Soothing Strong
Power
Button On/Off key
Press this key to turn
the equipment on

18
EN
For fine adjustment of shoulder position, after body shape detection, the remote
controller or a voice prompt will remind the user of fine adjustment of shoulder
position. If the massage roller stops at the shoulder position, directly press the OK
key to start massage. If not, use the Up key and Down key to
adjust the massage roller to the shoulder position, and then press the OK key
to start the massage. If no operation is made within 20s, directly default the current
massage roller position for the shoulder position and start massage.
Body sensing
Checking
Please wait
Skip
Power Pause
0
Power Pause
Shoulder position adjustment
ok
Skip
4. Wait until body shape detection is completed, or you can press the skip key
to skip detection and start massage directly.
OK
OK
Operation Instructions

EN
IV. Pause function (please use this function after the equipment is turned on)
After the massage chair is turned on, press the pause key to enter the pause
state, then all massage functions will be suspended, and press the pause key
again to resume the previous massage state.
Note: In the pause state, all functions do not work except shutdown.
Area
Shoulder
Home
Auto
Manual
Angle
Settings
Pause
Manual
Power
Relaxing
and Activating
Overall
Relaxation
Exclusive
for Family
AI
Intelligent
Auto Program
Zero pressure
stretch
Frozen
Shoulder Spine Care Buttock&leg
Care Joint Care
Schematic diagram of automatic massage program selection
Automatic program selection
(1) Select the Automatic key in the left menu bar to enter the automatic selection
interface.
19
Operation Instructions
Position too high
Proper position
Position too low
V. Automatic program (please use this function after the equipment is turned on)
(2) In the automatic program selection interface, there are 20 automatic programs to
choose from: Zero pressure stretch, Frozen Shoulder, Spine Care, Buttock&leg Care,
Joint Care, Energy, Lunch Break, Good-night sleep, Relieve Soreness, Body Balance,
President Cosy, Keep Fit, Meridian Treatment, White-collars Care, Restoration
Massage, Full-body stretch, Chinese Massage, Thai Massage, Spine Traction,
Psychic Communion.
(3) Click the desired automatic program to start the massage.
Table of contents
Languages:
Other iRest Massager manuals

iRest
iRest SL-A339 User manual

iRest
iRest Seat Cysion SL-D258S User manual

iRest
iRest A389-2 User manual

iRest
iRest GRANDEASE User manual

iRest
iRest SL-A11B User manual

iRest
iRest A710-12 User manual

iRest
iRest SL-C11 User manual

iRest
iRest SL-A385 User manual

iRest
iRest TEO-TIER SL-C30 User manual

iRest
iRest BM190 User manual

iRest
iRest ICOMFORT PLUS User manual

iRest
iRest A710-11 User manual

iRest
iRest SL-D180 User manual

iRest
iRest A38 User manual

iRest
iRest SL-A12Q User manual

iRest
iRest future foresee SL-A191 User manual

iRest
iRest SL-A321 User manual

iRest
iRest A306-48 User manual

iRest
iRest SL-C501 User manual

iRest
iRest SL-A306 User manual