manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Johnson Controls
  6. •
  7. Control Unit
  8. •
  9. Johnson Controls Facility Explorer FX20 User manual

Johnson Controls Facility Explorer FX20 User manual

Other manuals for Facility Explorer FX20

1

This manual suits for next models

2

Other Johnson Controls Control Unit manuals

Johnson Controls GS-20 Series User manual

Johnson Controls

Johnson Controls GS-20 Series User manual

Johnson Controls Tyco PRV-1A User manual

Johnson Controls

Johnson Controls Tyco PRV-1A User manual

Johnson Controls Tyco RSV-1 User manual

Johnson Controls

Johnson Controls Tyco RSV-1 User manual

Johnson Controls MS-NCM4510-2 User manual

Johnson Controls

Johnson Controls MS-NCM4510-2 User manual

Johnson Controls 300 Series User manual

Johnson Controls

Johnson Controls 300 Series User manual

Johnson Controls VF Series User manual

Johnson Controls

Johnson Controls VF Series User manual

Johnson Controls Tyco RV-1A User manual

Johnson Controls

Johnson Controls Tyco RV-1A User manual

Johnson Controls GM 20 Series User manual

Johnson Controls

Johnson Controls GM 20 Series User manual

Johnson Controls PENN P70 Series Manual

Johnson Controls

Johnson Controls PENN P70 Series Manual

Johnson Controls VP140 User manual

Johnson Controls

Johnson Controls VP140 User manual

Johnson Controls M300CJ User manual

Johnson Controls

Johnson Controls M300CJ User manual

Johnson Controls A19 Series User manual

Johnson Controls

Johnson Controls A19 Series User manual

Johnson Controls FX-PCX2721 User manual

Johnson Controls

Johnson Controls FX-PCX2721 User manual

Johnson Controls VMA 1410 Installation guide

Johnson Controls

Johnson Controls VMA 1410 Installation guide

Johnson Controls Tyco 8200-1466-01 User manual

Johnson Controls

Johnson Controls Tyco 8200-1466-01 User manual

Johnson Controls tyco AMD-2 User manual

Johnson Controls

Johnson Controls tyco AMD-2 User manual

Johnson Controls VP140 L Series User manual

Johnson Controls

Johnson Controls VP140 L Series User manual

Johnson Controls VP101DBB User manual

Johnson Controls

Johnson Controls VP101DBB User manual

Johnson Controls S300 Series Assembly instructions

Johnson Controls

Johnson Controls S300 Series Assembly instructions

Johnson Controls METASYS NU-XBN101-0 User manual

Johnson Controls

Johnson Controls METASYS NU-XBN101-0 User manual

Johnson Controls MP8000 Series User manual

Johnson Controls

Johnson Controls MP8000 Series User manual

Johnson Controls Mercury 3 Series Manual

Johnson Controls

Johnson Controls Mercury 3 Series Manual

Johnson Controls Tyco CV-300B User manual

Johnson Controls

Johnson Controls Tyco CV-300B User manual

Johnson Controls S300 Series Assembly instructions

Johnson Controls

Johnson Controls S300 Series Assembly instructions

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation Instructions FX20/60 RS-232
Issue Date April 9, 2014
© 2014 Johnson Controls, Inc. 1
Part No. 24-10174-85, Rev.C
FX Supervisory Controllers RS-232 Card
Installation Instructions
Applications
The RS-232 option card provides RS-232
communications capability to the FX
Supervisory Controllers. You can install up to
two RS-232 option cards per FX Supervisory
Controller. The port assignments are shown in
Figure 1.
For related information on FX Supervisory
Controllers mounting and wiring, refer to the
FX Supervisory Controllers Installation
Instructions (Part No. 24-10174-77).
Figure 1: FX Supervisory Controllers
RS-232 Card
North American Emissions
Compliance
United States
This equipment has been tested and found to
comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when this equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area may cause
harmful interference, in which case the users
will be required to correct the interference at
their own expense.
Canada
This Class (A) digital apparatus meets all
requirements of the Canadian Interference-
Causing Equipment Regulations.
Cet appareil numérique de la Classe (A)
respecte toutes les exigences du Règlement
sur le matériel brouilleur du Canada.
2FX Supervisory Controllers RS-232 Card Installation Instructions
Installation
Unpack the RS-232 option card and inspect
the contents of the package for damaged or
missing components. If the option card is
damaged, notify the appropriate carrier and
return any damaged components for repair or
replacement.
Parts Included
Included in this package are the following
items:
one RS-232 option card, along with
connector end plate
FX Supervisory Controllers RS-232 Card
Installation Instructions (Part No.
24-10174-85)
Special Tools Needed
To install the RS-232 card, use a number 2
Phillips screwdriver.
!
WARNING: Risk of Electric Shock.
Disconnect the power supply before making
electrical connections. Contact with
components carrying hazardous voltage can
cause electric shock and may result in
severe personal injury or death.
AVERTISSEMENT: Risque de décharge
électrique. Débrancher l'alimentation avant
de réaliser tout branchement électrique.
Tout contact avec des composants
conducteurs de tensions dangereuses
risque d'entraîner une décharge électrique
et de provoquer des blessures graves, voire
mortelles.
IMPORTANT: Make sure to plug any option
card into its connector properly (pins
aligned).
IMPORTANT: Avoid hot plug-in or the
removal of any option card from the FX
Supervisory Controllers (or other accessory
module). This means you must first remove
power from the unit.
Mounting
Mounting the RS-232 Card onto the FX
Supervisory Controllers
Mount the RS-232 card in either of the option
card slots on the FX Supervisory Controllers,
as available.
To mount the RS-232 card onto the
FX Supervisory Controllers:
1. If a station is running, stop it using the
platform Application Director view.
2. Remove power from FX Supervisory
Controller.
3. Remove the FX Supervisory Controller
cover. To do this, press in the four tabs on
both ends of the FX Supervisory Controller
and lift off the cover.
Note: If accessory modules are plugged
into the FX Supervisory Controllers, you
may need to slide them away from the unit
to access the cover tabs.
4. If the battery and bracket is installed,
remove it by taking out the four screws
holding the bracket in place. Set the
screws aside for later.
5. Unplug the battery from the connector on
the FX Supervisory Controllers (Figure 2).
FXSupervisory
Controll er
Figure 2: Removing the Battery Assembly
6. Remove the blanking end plate for the slot
you are installing the option card into.
Retain the blanking end plate in case you
want to remove the option card at a later
date.
7. Carefully insert the pins of the RS-232
card into the socket of the appropriate
option card slot. The mounting holes on
the RS-232 card should line up with the
standoffs on the FX Supervisory
FX Supervisory Controllers RS-232 Card Installation Instructions 3
Controllers. If they do not line up, the
connector is not properly aligned.
8. Press until the RS-232 card is completely
seated.
9. Place the custom end plate that came with
the RS-232 card over its connector
(Figure 3).
Figure 3: Inserting the RS-232 Card
10. If you are installing or replacing the
battery or bracket, plug the battery cable
into the battery connector on the FX
Supervisory Controller. See Figure 2 for
the location.
11. Set the battery and bracket assembly back
over the option card slots, with the
mounting holes aligned with the standoffs.
12. Place the four screws through the battery
bracket, end plates, and into the standoffs
on the FX Supervisory Controller. Hand
tighten these screws with a screwdriver.
Figure 4: Refastening the Screws
13. Replace the FX Supervisory Controller
cover. If accessory modules were
unplugged, plug them back into the FX
Supervisory Controller as before, and
secure.
14. Restore power to the controller and verify
normal operation.
Wiring
The RS-232 card uses standard DB-9M plug
and pinouts (it is identical to the RS-232 port
on the FX Supervisory Controller base). To
connect the FX Supervisory Controller RS-232
card with a Data Terminal Equipment (DTE)
device, use a null modem cable with DB9
connector.
Table 1: RS-232 Card Port Assignments
FX20/FX30E/FX60/FX60E FX70
Up to 2 RS-232 cards supported Up to 2 RS-232 cards supported
Option Slot 1 Option Slot 2 Option Slot 1 Option Slot 2
RS-232 =
COM3 RS-232 = COM4 RS-232 = COM5 RS-232 = COM6
RS-485 =
COM3, COM4 RS-232 = COM5 RS-485 = COM5,
COM6 RS-232 = COM7
LON = LON1 RS-232 = COM3 LON = LON1 RS-232 = COM5
Wireless TEC =
COM1 RS-232 = COM3 NA NA
Sedona =
COM3 RS-232 = COM4 Sedona = COM5 RS-232 = COM6
Modem =
COM1 RS-232 = COM3 Modem = COM3 RS-232 = COM5
GPRS = COM3,
COM4 RS-232 = COM5 GPRS = COM5,
COM6 RS-232 = COM7
4FX Supervisory Controllers RS-232 Card Installation Instructions
Table 2: COM Assignment for RS-232 Card in Option Slot 2
Pinout References Signal DB-9 Plug Pin
DB-9 Plug (Male)
DCD Data carrier
detect 1
RXD Receive data 2
TXD Transmit data 3
DTR Data terminal
ready 4
GND Ground 5
DSR Data set ready 6
RTS Request to send 7
CTS Clear to send 8
9
Repair Information
If the RS-232 option card fails to operate
within its specifications, replace the unit.
For a replacement option card, contact the
nearest Johnson Controls® representative.
Operation
LEDs
Two LEDs are visible on the top of the
RS-232 option card when the cover is
removed from the FX Supervisory
Controller. These LEDs are as follows:
RX (green): Receive. Indicates that
the FX Supervisory Controller is receiving
data from a device.
TX (yellow): Transmit. Indicates that
the FX Supervisory Controller is
transmitting a message to a device.
Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
Johnson Controls® is a registered trademark of Johnson Controls, Inc.
All other marks herein are the marks of their respective owners. © 2014 Johnson Controls, Inc.