Page 1 of 2 AUGUST 2022 TFP179
Worldwide
Contacts
www.tyco-fire.com
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER
WARNING” that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Scan the QR code or enter the URL
in a web browser to access the most
up-to-date electronic version of this
document. Data rates may apply.
docs.jci.com/tycore/tfp179
Model TY3201 – 80 K-factor
Pendent Sprinkler
Quick Response, Standard Coverage
General
Description
TYCO Model TY3201 80K Quick
Response Pendent Sprinklers are
standard coverage, small frame, 3 mm
glass bulb-type spray sprinklers.
NOTICE
The Model TY3201 Quick Response
Pendent Sprinklers described herein
must be installed and maintained in
compliance with this document, as well
as with the applicable standards of the
National Fire Protection Association
(NFPA), in addition to the standards of
any other authorities having jurisdiction.
Failure to do so may impair the perfor-
mance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identication
Number (SIN)
TY3201 . . . Pendent 80K, 1/2 in. NPT
Technical
Data
Approvals
UL and C-UL Listed
FM Approved
Maximum Working Pressure
249.5 (17,2 bar), UL and C-UL
175.5 (12,1 bar), FM Approvals
Pipe Thread Connection
1/2 in. NPT
Discharge Coefficient
K=80 lpm/psi½
Temperature Ratings
154.4°F (68°C)
Finish
Sprinkler: Chrome Plated
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze
Button . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze
Sealing Assembly ..Beryllium Nickel w/TEFLON
Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass
Compression Screw . . . . . . . . . . . . . . . . .Bronze
Deector . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Operation
The glass bulb contains a uid that
expands when exposed to heat. When
the rated temperature is reached, the
uid expands sufciently to shatter the
glass bulb, allowing the sprinkler to
activate and ow water.
Design
Criteria
TYCO Model TY3201, Quick Response,
Standard Coverage, 80K Pendent
Sprinklers are intended for re protec-
tion systems designed in accordance
with the standard installation rules
recognized by the applicable listing or
approval agency - for example, the UL
Listing is based on the requirements of
NFPA 13.
TFP179
Page 2 of 2
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
TEFLON is a trademark of The Chemours Company FC, LLC
1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220
© 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
Installation
TYCO Model TY3201, Quick Response,
Standard Coverage, 80K Pendent
Sprinklers must be installed in accor-
dance with this section.
NOTICE
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1,6 mm.
Install pendent sprinklers only in the
pendent orientation with the deflector
parallel to the mounting surface.
General Instructions
A leak-tight 1/2 inch NPT sprinkler
joint should be obtained with a torque
of 7.0 ft-lb to 14.0 ft-lb (9,5 N·m to
19,0 N·m). Higher levels of torque may
distort the sprinkler inlet with conse-
quent leakage or impairment of the
sprinkler.
Do not attempt to compensate for
insufcient adjustment of an escutch-
eon plate by under- or over-tightening
the sprinkler. Readjust the position of
the sprinkler tting to suit.
Step 1. After installing an escutcheon,
as applicable, over the sprinkler pipe
threads, and with pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
tting.
Step 2. Wrench-tighten pendent sprin-
klers using only the W-Type 6 (End A)
sprinkler wrench. Apply the wrench
recess of the sprinkler wrench shown
in Figure 2 to the sprinkler wrench ats
shown in Figure 1.
Care and
Maintenance
TYCO Model TY3201, Quick Response,
Standard Coverage, 80K Pendent
Sprinklers must be maintained and ser-
vices in accordance with this section.
Before closing a re protection system
main control valve for maintenance
work on the re protection system that
it controls, permission to shut down the
affected re protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notied.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb For information
about replacing a sprinkler, see the
Installation Section.
The owner is responsible for the
inspection, testing, and maintenance of
their re protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Associ-
ation such as NFPA 25, in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
It is recommended that automatic
sprinkler systems be inspected, tested,
and maintained by a qualied Inspec-
tion Service in accordance with local
requirements and/or national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-re.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and Part Number
(P/N).
Sprinkler Assemblies with
NPT Thread Connections
Specify: Model TY3201, Quick
Response Pendent Sprinklers,
68°C, with Chrome Plated finish,
P/N 51-014-9-155
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
WRENCH RECESS
(USE END "A" FOR
MODEL TY3201)
-
2
Button
Temperature
rating is
indicated on
Deector.
Deector
Compression
Screw
Bulb
Sealing
-
6
*
-
4
5
-
3
-
*
*
6
4
5
1
3
2
Components:
Frame
1
-
1/2"
NPT
11,1 mm
MAKE-IN
NOMINAL
WRENCH
52,4 mm
FLATS
25,7 mm
Assembly
FIGURE 1
QUICK RESPONSE
MODEL TY3201 PENDENT SPRINKLER
80 K-FACTOR, 1/2 INCH NPT
FIGURE 2
W-T YPE 6
SPRINKLER WRENCH

Other Johnson Controls Irrigation System manuals

Johnson Controls tyco CC3 User manual

Johnson Controls

Johnson Controls tyco CC3 User manual

Johnson Controls tyco TY3596 User manual

Johnson Controls

Johnson Controls tyco TY3596 User manual

Johnson Controls tyco DS-1 Series User manual

Johnson Controls

Johnson Controls tyco DS-1 Series User manual

Johnson Controls Tyco TY720 User manual

Johnson Controls

Johnson Controls Tyco TY720 User manual

Johnson Controls tyco ESFR-17 User manual

Johnson Controls

Johnson Controls tyco ESFR-17 User manual

Johnson Controls Tyco RFIII User manual

Johnson Controls

Johnson Controls Tyco RFIII User manual

Johnson Controls tyco EC-8C Series User manual

Johnson Controls

Johnson Controls tyco EC-8C Series User manual

Johnson Controls tyco TY-B Series User manual

Johnson Controls

Johnson Controls tyco TY-B Series User manual

Johnson Controls tyco ULTRA K17 User manual

Johnson Controls

Johnson Controls tyco ULTRA K17 User manual

Johnson Controls tyco RAVEN User manual

Johnson Controls

Johnson Controls tyco RAVEN User manual

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls tyco TY720 User manual

Johnson Controls

Johnson Controls tyco TY720 User manual

Johnson Controls tyco DS-1 Series User manual

Johnson Controls

Johnson Controls tyco DS-1 Series User manual

Johnson Controls tyco TFP PH2 User manual

Johnson Controls

Johnson Controls tyco TFP PH2 User manual

Johnson Controls tyco RAPID RESPONSE LFII Series User manual

Johnson Controls

Johnson Controls tyco RAPID RESPONSE LFII Series User manual

Johnson Controls tyco LD User manual

Johnson Controls

Johnson Controls tyco LD User manual

Johnson Controls Tyco ULF AM6 User manual

Johnson Controls

Johnson Controls Tyco ULF AM6 User manual

Johnson Controls MS1 Manual

Johnson Controls

Johnson Controls MS1 Manual

Johnson Controls tyco AQUAMIST IFP User manual

Johnson Controls

Johnson Controls tyco AQUAMIST IFP User manual

Johnson Controls C-9500 User manual

Johnson Controls

Johnson Controls C-9500 User manual

Johnson Controls DS-2 Series User manual

Johnson Controls

Johnson Controls DS-2 Series User manual

Johnson Controls tyco WS User manual

Johnson Controls

Johnson Controls tyco WS User manual

Johnson Controls tyco DSB-2 User manual

Johnson Controls

Johnson Controls tyco DSB-2 User manual

Popular Irrigation System manuals by other brands

Hunter PGP Ultra Series manual

Hunter

Hunter PGP Ultra Series manual

Reliable G5-56 Bulletin

Reliable

Reliable G5-56 Bulletin

Tyco EC-11 Series manual

Tyco

Tyco EC-11 Series manual

Hunter Professional PGP Ultra Series quick start guide

Hunter

Hunter Professional PGP Ultra Series quick start guide

Reliable F1FR quick start guide

Reliable

Reliable F1FR quick start guide

Rain SuperPro S075 S Setting instructions

Rain

Rain SuperPro S075 S Setting instructions

BERMAD Omega Installation and operation guide

BERMAD

BERMAD Omega Installation and operation guide

Viking 10224 Technical data

Viking

Viking 10224 Technical data

Underhill Mirage M-125 Operating and maintenance instructions

Underhill

Underhill Mirage M-125 Operating and maintenance instructions

Netafim SPINNET Handbook

Netafim

Netafim SPINNET Handbook

Baccara G75 user manual

Baccara

Baccara G75 user manual

Tyco ESFR-17 manual

Tyco

Tyco ESFR-17 manual

Reliable F1 LO Bulletin

Reliable

Reliable F1 LO Bulletin

Viking VK3502 Technical data

Viking

Viking VK3502 Technical data

Tyco Fire Protection Products PROTECTOSPRAY EA-1 manual

Tyco Fire Protection Products

Tyco Fire Protection Products PROTECTOSPRAY EA-1 manual

Tyco TY-FRL Series quick start guide

Tyco

Tyco TY-FRL Series quick start guide

Gardeners Snip-n-Spray manual

Gardeners

Gardeners Snip-n-Spray manual

AQUAJOE AJ-OSPR20 quick start guide

AQUAJOE

AQUAJOE AJ-OSPR20 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.