manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Johnson Controls
  6. •
  7. Irrigation System
  8. •
  9. Johnson Controls tyco AQUAMIST ULF AM15 User manual

Johnson Controls tyco AQUAMIST ULF AM15 User manual

Ultra Low Flow AQUAMIST Nozzle
Type ULF AM15
Non-Automatic (Open)
Page 1 of 2 JANUARY 2019 TFP2215
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER
WARNING” that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Worldwide
Contacts
www.tyco-fire.com
General
Description
The TYCO Ultra Low Flow AQUAMIST
Nozzle Type ULF AM15 is an upright,
stainless steel, open (non-automatic)
intermediate pressure nozzle which uti-
lizes a single fluid jet impinging on a dif-
fuser to produce a spray having a range
of water droplet sizes. It is intended for
use in engineered, water mist deluge
systems in marine applications under
the Guidelines for Approval of Fixed
Water-Based Local Application Fire –
Fighting Systems for Use in Category
A Machinery Spaces, MSC/Circ. 913
(4 June 1999).
It is recommended that the end user be
consulted with respect to the suitabil-
ity of the materials of construction and
finish for any given corrosive environ-
ment. The effects of ambient tempera-
ture, concentration of chemicals, and
gas/chemical velocity, should be con-
sidered, at a minimum, along with the
corrosive nature to which the nozzles
may be exposed.
NOTICE
The Type ULF AM15 AQUAMIST
Nozzles described herein must be
installed and maintained in compliance
with this document, as well as with the
applicable standards of the NATIONAL
FIRE PROTECTION ASSOCIATION
(NFPA), in addition to the standards of
any other authorities having jurisdiction.
Failure to do so may impair the perfor-
mance of these devices.
The design of individual watermist
systems can vary considerably,
depending on the characteristics and
nature of the hazard and the basic
purpose of the watermist system.
Because of these variations, the design
of watermist systems for fire protec-
tion must only be performed by expe-
rienced designers who thoroughly
understand the limitations as well as
capabilities of such systems.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Technical
Data
Approvals
UL Certified
Tested to IMO MSC/Circ. 913 (4 June 1999)
Minimum Working Pressure
175 psi (12 bar)
Maximum Working Pressure
250 psi (17,2 bar)
Discharge Coefficient
K = 0.33 GPM/psi½(K = 4,7 LPM/bar½)
Thread Connection
1/2 in. NPT
Physical Characteristics
Frame ..................... Stainless Steel
Strainer . . . . . . . . . . . . . . . . . . . . Stainless Steel
Orifice Insert . . . . . . . . . . . . . . . . Stainless Steel
Diffuser . . . . . . . . . . . . . . . . . . . . Stainless Steel
Shield ..................... Stainless Steel
The smallest waterway (orifice) diameter
of the Orifice Insert is nominally 0.106 in.
(2,69 mm), and the diameter of the Inlet
Strainer perforations are nominally 0.060 in.
(1,52 mm).
Design
Criteria
Obtain guidance for the design of
a watermist system that utilizes the
TYCO Type ULF AM15 AQUAMIST
Nozzles from the Technical Services
Department.
Installation
The TYCO Type ULF AM15 AQUAMIST
Nozzles must be installed in accor-
dance with this section:
General Instructions
A leak tight 1/2 in. NPT nozzle joint
should be obtained with a torque of
7 to 14 lb-ft (9,5 to 19,0 N·m). Higher
levels of torque may distort the nozzle
inlet and cause leakage or impairment
of the nozzle.
Nozzles must be installed using 0.1 m
minimum length pipe extensions as
illustrated in Figure 3.
Step 1. With pipe thread sealant
applied to the pipe threads, hand
tighten the nozzle into the nozzle fitting.
Step 2. Tighten the nozzle into the
nozzle fitting using only the W-Type 11
Sprinkler Wrench (Ref. Figure 2). With
reference to Figure 1, the W-Type 11
Sprinkler Wrench is to be applied to
the wrenching area.
TFP2215
Page 2 of 2
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700
© 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
Care and
Maintenance
The TYCO Type ULF AM15 AQUAMIST
Nozzles must be maintained and ser-
viced in accordance with this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shut down the
affected fire protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
Non-automatic nozzles must never be
painted, plated, coated or otherwise
altered after leaving the factory; oth-
erwise, the spray performance may be
impaired. Modified nozzles must be
replaced if they cannot be completely
cleaned by wiping the nozzle with a
cloth or by brushing it with a soft bristle
brush.
Care must be exercised to avoid
damage to the nozzles before, during,
and after installation. Nozzles damaged
by dropping, striking, wrench twist/slip-
page, or the like, must be replaced.
Frequent visual inspections are rec-
ommended to be initially performed
for nozzles installed in potentially cor-
rosive atmospheres to verify the integ-
rity of the materials of construction and
finish as they may be affected by the
corrosive conditions present for a given
installation. Thereafter, annual inspec-
tions per NFPA 25 are required.
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the NATIONAL FIRE PROTECTION
ASSOCIATION, for example, NFPA
25, in addition to the standards of any
authority having jurisdiction. Contact
the installing contractor or product
manufacturer with any questions.
Water mist systems should be
inspected, tested, and maintained by
a qualified Inspection Service in accor-
dance with local requirements and/or
national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order, indi-
cate the full product name and Part
Number.
Type AM15 AQUAMIST Nozzle
Specify: Type ULF AM15 AQUA-
MIST Nozzle, Stainless Steel,
P/N 49-215-0-001
Sprinkler Wrench
Specify: W-Type 11 Sprinkler Wrench,
P/ N 56-452-1-0 01
FIGURE 3
TYPE ULF AM15
AQUAMIST NOZZLE
INSTALLATION ARRANGEMENT
Components:
Diffuser
Strainer
Frame
Shield
Insert
Orice
-
3
4-
-
1
2-
-
5
1/2" NPT
WRENCHING
AREA
FACE OF
NOZZLE
FITTING
1-3/4"
(44,5 mm)
13/16"
(20,6 mm)
7/16" (11,1 mm)
NOMINAL MAKE-IN
1-7/16"
(36,5 mm)
2-1/2"
(63,5 mm)
5
1
2
3
4
SUPPLY
PIPE
3/4" x 1/2"
(20 mm x 15 mm)
REDUCING
COUPLING
3/4" (20 mm)
PIPE NIPPLE
4" (0,1 m)
MINIMUM
TYPE AM15
NOZZLE
FIGURE 1
TYPE ULF AM15 AQUAMIST NOZZLE
NOMINAL DIMENSIONS
FIGURE 2
W-T Y PE 11
SPRINKLER WRENCH

This manual suits for next models

1

Other Johnson Controls Irrigation System manuals

Johnson Controls tyco AQUAMIST ULF AM34 User manual

Johnson Controls

Johnson Controls tyco AQUAMIST ULF AM34 User manual

Johnson Controls Tyco AQUAMIST AM31 User manual

Johnson Controls

Johnson Controls Tyco AQUAMIST AM31 User manual

Johnson Controls SABROE NS-HPAC User manual

Johnson Controls

Johnson Controls SABROE NS-HPAC User manual

Johnson Controls DS-2 Series User manual

Johnson Controls

Johnson Controls DS-2 Series User manual

Johnson Controls tyco ESFR-17 User manual

Johnson Controls

Johnson Controls tyco ESFR-17 User manual

Johnson Controls tyco EC-5 Series User manual

Johnson Controls

Johnson Controls tyco EC-5 Series User manual

Johnson Controls tyco CC2 User manual

Johnson Controls

Johnson Controls tyco CC2 User manual

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls tyco TY2235 User manual

Johnson Controls

Johnson Controls tyco TY2235 User manual

Johnson Controls tyco CWS User manual

Johnson Controls

Johnson Controls tyco CWS User manual

Johnson Controls Tyco TY3201 User manual

Johnson Controls

Johnson Controls Tyco TY3201 User manual

Johnson Controls tyco LD User manual

Johnson Controls

Johnson Controls tyco LD User manual

Johnson Controls tyco ULTRA K17 User manual

Johnson Controls

Johnson Controls tyco ULTRA K17 User manual

Johnson Controls Tyco RFIII User manual

Johnson Controls

Johnson Controls Tyco RFIII User manual

Johnson Controls tyco RFII Series User manual

Johnson Controls

Johnson Controls tyco RFII Series User manual

Johnson Controls tyco DSB-2 User manual

Johnson Controls

Johnson Controls tyco DSB-2 User manual

Johnson Controls tyco AQUAMIST IFP User manual

Johnson Controls

Johnson Controls tyco AQUAMIST IFP User manual

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls tyco ESFR-25 User manual

Johnson Controls

Johnson Controls tyco ESFR-25 User manual

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls tyco ESFR-34 User manual

Johnson Controls

Johnson Controls tyco ESFR-34 User manual

Johnson Controls tyco TY-L Series User manual

Johnson Controls

Johnson Controls tyco TY-L Series User manual

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls SABROE SVER User manual

Johnson Controls

Johnson Controls SABROE SVER User manual

Popular Irrigation System manuals by other brands

Senninger i-Wob UP3 Recommended installation

Senninger

Senninger i-Wob UP3 Recommended installation

Reliable F3QR manual

Reliable

Reliable F3QR manual

Reliable F1 Series Bulletin

Reliable

Reliable F1 Series Bulletin

Viking VK531 Technical data

Viking

Viking VK531 Technical data

Autopot 80Pot XL Set-up guidelines

Autopot

Autopot 80Pot XL Set-up guidelines

Tyco ESFR-25 manual

Tyco

Tyco ESFR-25 manual

Rain Bird Falcon 6504 Installation and operating guide

Rain Bird

Rain Bird Falcon 6504 Installation and operating guide

Tyco LFII Series quick start guide

Tyco

Tyco LFII Series quick start guide

Signature 6700 Pro Impact instruction manual

Signature

Signature 6700 Pro Impact instruction manual

Autopot 16Pot XL Set-up guidelines

Autopot

Autopot 16Pot XL Set-up guidelines

Reliable DDX Type D Instructions for installation, operation care and maintenance

Reliable

Reliable DDX Type D Instructions for installation, operation care and maintenance

Tyco ELO-231 Series quick start guide

Tyco

Tyco ELO-231 Series quick start guide

GREENLINE EcoAqua DripSystem EADS-12 manual

GREENLINE

GREENLINE EcoAqua DripSystem EADS-12 manual

Weathermatic SmartLink SL-AIRCARDFLOW owner's manual

Weathermatic

Weathermatic SmartLink SL-AIRCARDFLOW owner's manual

Viking MICROMATIC VK104 Technical data

Viking

Viking MICROMATIC VK104 Technical data

Reliable G6-80 K8.0 quick start guide

Reliable

Reliable G6-80 K8.0 quick start guide

Eden 94801-EDAMZ quick start guide

Eden

Eden 94801-EDAMZ quick start guide

Tyco Fire Product Star PH-5 instruction manual

Tyco Fire Product

Tyco Fire Product Star PH-5 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.