© SAFLOK, all rights reserved. INS_MTRFID_2_12
MTTM RFID Installation Instructions Pg 8 of 8
SAFLOK Door Unit Inspection Criteria
Appearance
• Finishisfreeofblemishesorscratchesthatwoulddistractfromlockappearance
• Lockbodyandunderplate(ifused)aremountedstraightonthedoor
• Doorscalpismountedstraightandushwiththedooredge
• Jambstrikeismountedstraightandisushwiththejambface
• Correctionofminorblemishesonthedoorjambaretheresponsibilityoftheproperty’smaintenancedepartment
Lock Function
• Knoborleverrotatesandmovesfreely
• Leverishorizontaltooorwhenatrestposition
• Deadboltextendsfullyandretractswithoutbinding(dooropen)
• Locklatchanddeadboltengagejambstrikeplatefreely
• Anti-picklatchwhendepressed(dooropen)
• Anti-picklatchisdepressedwhencontactismadewiththestrikeplate(doorclosed)
Electronics/Keycards
• Greenlightasheswhentheproperkeycardisused
• Greenlightisashingwhentheleverisoperated
• Greenlightcontinuestoashforave-secondcycle
• Yellowlightashes12timeswhenthedeadboltisextendedandaguest/hotelkeycardisused
• Allkeycardsfunctiontothespecicationsofthepropertieskeydesign
Door function
• Doorclosesandlatcheswithlittleornointerference
• Deadboltextendsfullythroughthestrikeplatewithoutinterference(doorclosed)
• Spacingbetweendooredgeandinsidedoorjambdoesnotexceed3/16”(doorclosed)
Note: If bumpers or other seals are added after strike plate installation and causes alignment and latch problems, it
is the property’s responsibility to correct this condition. This note generally applies to new construction or new door
installation
Questions? Call Customer Service at 800.999.6213 and select option 3. For online assistance, visit support.saflok.com.
FCC and IC Warnings: This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
© SAFLOK, all rights reserved. INS_MTRFID_2_12