manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kilotech
  6. •
  7. Scale
  8. •
  9. Kilotech KWS 301 User manual

Kilotech KWS 301 User manual

Other manuals for KWS 301

1

This manual suits for next models

4

Other Kilotech Scale manuals

Kilotech KPC 5000 User manual

Kilotech

Kilotech KPC 5000 User manual

Kilotech KWD 500 Use and care manual

Kilotech

Kilotech KWD 500 Use and care manual

Kilotech Integrator LE.3k User manual

Kilotech

Kilotech Integrator LE.3k User manual

Kilotech Abacus AB30 User manual

Kilotech

Kilotech Abacus AB30 User manual

Kilotech KWD 15K User manual

Kilotech

Kilotech KWD 15K User manual

Kilotech KWS-SW series User manual

Kilotech

Kilotech KWS-SW series User manual

Kilotech KWS 2200 User manual

Kilotech

Kilotech KWS 2200 User manual

Kilotech KHA Series User manual

Kilotech

Kilotech KHA Series User manual

Kilotech KRS 3000 User manual

Kilotech

Kilotech KRS 3000 User manual

Kilotech 851340 Installation manual

Kilotech

Kilotech 851340 Installation manual

Kilotech S-2000 User manual

Kilotech

Kilotech S-2000 User manual

Kilotech KIN 500 User manual

Kilotech

Kilotech KIN 500 User manual

Kilotech KLE 200 User manual

Kilotech

Kilotech KLE 200 User manual

Kilotech Integrator C30 User manual

Kilotech

Kilotech Integrator C30 User manual

Kilotech KPC-2000 User manual

Kilotech

Kilotech KPC-2000 User manual

Kilotech MS-4202L Adult User manual

Kilotech

Kilotech MS-4202L Adult User manual

Kilotech KWS 301 User manual

Kilotech

Kilotech KWS 301 User manual

Kilotech KPC 1000SS User manual

Kilotech

Kilotech KPC 1000SS User manual

Kilotech KBS Series User manual

Kilotech

Kilotech KBS Series User manual

Kilotech KPS MS User manual

Kilotech

Kilotech KPS MS User manual

Kilotech Integrator LE.3k User manual

Kilotech

Kilotech Integrator LE.3k User manual

Kilotech KPC 160 User manual

Kilotech

Kilotech KPC 160 User manual

Kilotech KPC 1500SS Use and care manual

Kilotech

Kilotech KPC 1500SS Use and care manual

Kilotech 851340 User manual

Kilotech

Kilotech 851340 User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

KWS 301
OPERATION MANUAL
851243 AND 851253
Contents subject to change without notice
MAN02272020
Ce manuel est disponible en français à www.kilotech.com
2
TABLE OF CONTENTS
TABLE OF CONTENTS .................................................................................................................. 2
Introduction .............................................................................................................................. 2
General Precautions................................................................................................................... 3
Specifications............................................................................................................................. 4
Outline ...................................................................................................................................... 4
Unpacking and setup ............................................................................................................... 25
Contents.................................................................................................................................. 25
Weighing operations................................................................................................................ 25
Key functions............................................................................................... Error! Bookmark not defined.
Introduction
Thank you for choosing a Kilotech Scale. We appreciate your business and hope that you will enjoy using your
scale. Should you require support, please contact your local dealer from whom you have purchased.
General Precautions
Avoid lengthy exposure to heat
or cold.
Allow the scale to acclimate to normal room temperature before
use.
Allow sufficient warm up time.
Turn the scale on and wait for a few minutes to allow the internal
components a chance to stabilize before weighing.
Do not leave a load or weight
on a scale for a prolonged
period of time.
Do not tamper with the scale
yourself.
This will void the warranty. Contact your local distributor to
properly repair your scale.
Do not disassemble the scale
yourself.
This will void the warranty. Contact your local distributor to
properly repair your scale.
Do not load beyond the
maximum weight limit.
Do not pull the plug by its cord
when unplugging.
Do not use the scale near fire
or corrosive gas.
Do not spill water or immerse
in water.
Avoid placing the scale near a
heater.
It could cause a fluctuation to the indicator reading.
Always make sure to use a
Kilotech approved adapter.
Do not drop the scale or apply
a sudden shock.
Do not drag the scale.
Avoid exposing to other
electromagnetic devices.
These devices emit RF and can cause unstable readings. If your
scale should perform poorly, try moving the scale to a different
room or location.
Level the scale or make sure it
is on an even surface.
A scale used on an uneven surface may provide an unstable
reading.
Scale should be used within
stated temperature.
A
B
C
D
E
292mm/11.5"
362mm/14.25"
127mm/5"
279mm/11"
241mm/9.5"
Specifications
Product Number
851243
851253
Product Name
KWS 301-15
KWS 301-30
Capacity
30 LB. / 15 KG
66 LB. / 30 KG
Graduation
0.001 LB. / 0.0005 KG
0.002 LB. / 0.001 KG
Weighing Modes
LB. /KG
Display
6 DIGIT LCD
Back Light
YES
Auto Power Off
Power
AC 110 V OR 220 V DC 6V
Battery
RECHARGEABLE BATTERY 861255
Product Dimensions
11.5 X 14.25 X 5 INCHES
Platter Size
11 X 9.5 INCHES STAINLESS STEEL
Operating Temperature / Humidity
0° C ~40° C/ 32° F ~104° F
Outline
Note that the levelling bubble is situated under the left hand side of the platter and the ON/Off switch is located
on the bottom right hand side of the scale.
C
C
Unpacking and setup
Remove the scale from the box and place it on a firm, level surface.
Avoid locations with rapid temperature changes, excessive dust, moisture, air currents, vibrations,
electromagnetic fields, heat or direct sunlight.
NOTE: Ensure that the scale is level each time its location is changed.
Before using the scale for the first time, the internal rechargeable battery should be fully charged for at
least 12 hours.
Allow the instrument to warm up for 30 minutes prior to use.
Connect the supplied AC adapter to the power input receptacle. Plug the AC adapter into a power outlet
and the battery will begin charging. Do not operate the scale with the charger continuously plugged in.
Adapter should be used only for charging purposes.
If the scale will be stored or transported in the future, save the packaging material to ensure the best
possible protection for the scale.
Caution: Changes or modifications not expressly approved by the manufacturer could void the user’s
authority to operate this equipment.
Contents
KWS 301 scale, adapter, rechargeable battery, manual
Weighing Operations
Illustration of display board
1. “~”: Scale is stable.
2. NET: Net weight.
3. “→0←”: Zero.
4. Charge: Red light indicates that the scale is being charged. Green light indicates that the battery is fully
charged.
5. Lb: unit is lb
6. kg/g: unit is kg/g
Function keys
a. This is not a key but a label located on the right hand side of the scale to indicate where the
power switch is.
Calculates the former weighing results
Displays total weight
Unit key allows you to switch between kg or lb
ON
M+
enter
MR
U
Zero key
Tare key
Clears the record
Operating your scale
A. Getting started
Turn the instrument on by pressing the power switch on.
The display will count down from 999999….while the unit is being updated.
Allow the unit to warm-up for 30 minutes.
B. Taring
All models have taring capabilities up to their total weight capacity.
To weigh a sample in its container, with the display showing the weight of the sample, use the following
procedure.
1. Place an empty container on pan and then press the key. The ▼will point to the NET annunciator
and the weight display will show zero.
2. Place the sample in its container on the scale.
3. When the scale is stable, the display will show the weight of the sample.
4. After taking away the container, a minus value will be displayed on the screen. Press the key to
return to zero.
C. Zeroing
Press the key before weighing the samples to zero the scale.
D. Accumulation function
1. Press the key. Put the item on the platter and press M+. Once you remove the item it will revert
back to zero. Place the second item on the platter and press M+. Repeat this for as many items as you have to
accumulate. Display will show with the weight:
2. The next accumulation will show with the weight:
3.Press the key to show the total times you weighed (i.e. ACC2 for two items) and subsequently the
total weight at the end.
→0
←
→0
←
CE
4.Press the key to delete all the data in the total weight, and return to the normal weight display.
E. Programming the scale
1.Press and hold any key while powering ON, the display will shows
2.Press key the screen shows
3. Auto power off: The scale switches off automatically after the set time period.
Press the key for parameter selection and press the key
for setting the program sequence as follows:
4. Backlight –Press the setting to change the backlight settings.
Press the M+ key to move from Autopower to Backlight settings.
F. Recharging the battery
a. The low battery light ,“LOBAT”, will flash when it is time to recharge your battery. You can use your scale for
about ten hours from the time you are first notified that the battery needs to be recharged.
b. When the message “LOBAT” appears on your LCD screen, turn off the power switch immediately and begin
recharging the battery to prolong its life.
Notes
a. The scale has a built-in charger. Always use the adapter that came with the scale.
b. What the light colors mean:
1. RED –Need to charge the battery
2. Orange –charging is in progress
3. Green –charging is complete.
c. A complete charge takes 8-10 hours.