These instructions should be read carefully and retained after installation by the end user for future
reference and maintenance.
These instructions should be used to aid installation of the following products:
LEDBATW35 / LEDBATW44 / LEDBATW50
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• Installation of this luminaire should only be carried out by a qualified electrician or competent
person to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for
installation
• This product is Class I and requires an earth
• This product series is IP20 rated
• This product is non-dimmable
Note - If this luminaire is being used in conjunction with external PIR or sensors please
confirm with manufacturer of these sensors that they are compatible with LED luminaires.
• Provide power to the required point of installation
• Remove the base mounting bracket and use as a template - ensure the base mounting
brackets are evenly spaced in order to distribute the weight evenly
• Drill the holes ensuring not to infringe with any joists, gas / water pipes or electrical
cables
• Remove panel on the rear of the luminaire to gain access to the mains terminal block
(please see Fig 1)
LEDBATW__series
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproducts:
LEDBATW35,LEDBATW44,LEDBATW50
SAFETY
• Installationofthisluminaireshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
latestBuildingandcurrentIEEWiringRegulations(BS7671)
• Pleaseisolatemainspriortoinstallation/maintenance
• Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
• PleasenotetheIP(IngressofProtection)ratingofthisluminairewhendecidingthelocationforinstallation
• ThisproductisClassIandrequiresanearth
• ThisproductseriesisIP20rated
• Thisproductisnon-dimmable
INSTALLATION
Note-IfthisluminaireisbeingusedinconjunctionwithexternalPIRorsensorspleaseconfirmwithmanufacturerofthese
sensorsthattheyarecompatiblewithLEDluminaires.
• Providepowertotherequiredpointofinstallation
• Removethebasefixingbracketsanduseasatemplate-ensurethebasemountingbracketsareevenlyspaced
inordertodistributetheweightevenly
• Drilltheholesensuringnottoinfringewithanyjoists,gasorwaterpipesorelectricalcables
• Removepanelontherearoftheluminairetogainaccesstothemainsterminalblock(pleaseseefig1)
Fig1
• Ensuringcorrectpolarityisobserved,carefullywireasshowninFig2
Fig2
• Fixluminairetobasemountingfixing
• Switchonpowersupplyandcheckforcorrectoperation
GENERAL
Theunitshouldberecycledinthecorrectmannerwhenitreachestheendofitslife.Checklocalauthoritiesforwhere
facilitiesexist.
Fig 1