manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Konica Minolta
  6. •
  7. Measuring Instrument
  8. •
  9. Konica Minolta CM-3600D User manual

Konica Minolta CM-3600D User manual

Personal Computer
Accessory Case
CM-A209
Dust Cover
CM-A110
(CM-3600d)
CM-A118
(CM-3610d)
Opacity Jig
CM-A134
(only CM-3610d)
Spectrophotometer CM-3600d/CM-3610d
Standard accessories Optional accessories
Target Mask
CM-A105
( 25.4mm)
AC Adapter AC-A12
AC Adapter AC-A21 (for Korea)
RS-232C Cable IF-A12
(9-pin, 2m)
White Calibration Plate CM-A103
(with containing calibration data)
Target Mask
CM-A106
( 8mm)
Target Mask
CM-A107
( 4mm)
Cell
CM-A99
(20mm)
Cell
CM-A98
(10mm)
Cell
CM-A97
(2mm)
Plastic Cell
CM-A132
(20mm; set for 100)
Plastic Cell
CM-A131
(10mm; set for 100)
Plastic Cell
CM-A130
(2mm; set for 100)
only CM-3600d
Transmittance.
Zero Calibration Plate
CM-A100
Transmittance
Specimen Holder
CM-A96
Zero Calibration Box
CM-A104
(CM-3600d)
Zero Calibration Box
CM-A119
(CM-3610d)
RS-232C Cables IF-A13
(9-pin, 5m)
Color Tiles
SpectraMagicTM NX
CM-S100w
System
Diagram
Specifications
Network construction for color control either within
an organization or between organizations
Built for Precision,
Priced for Economy
Outstanding Performance through Innovative Technology
CM-3600d Horizontal Spectrophotometer
Highly accurate, reliable and rugged
Versatile instrument for most colorimetric applications
Simplified operation.
CM-3610d Vertical Spectrophotometer for best application support
Speeds up textile and paper measurements
Ideal for non contact measurements such as powders, pigments
Quick sample handling and observation
In-house color control
Color control between companies
R&D
Design Production
Company
A
Company
B
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series
CM-3600d
CM-3610d
CM-3500d
CM-2600d/2500d/2500c
"State of the Art" Reference models
Laboratory and Production Model(horizontal)
Laboratory and Production Model(vertical)
Unique Top Port bench-top model
Top class accuracy portables
CM-3500d
CM-3700d
CM-2000/2600d
series 2500d
CM-3600d
CM-3610d
High inter-instrument agreement between the same Konica Minolta
model and also among all CM models (benchtops and portables):
CM-2000 series, CM-3000 series,
This inter-instrument agreement is ideal when multiple units will be
used for color control either within an organization or between
organizations.
Weight
Size (W x H x D)
Storage temperature/
humidity range
Operating temperature/
humidity range
(*1)
Power
Interface
Transmittance
chamber
UV cut filter
UV adjustment
Temperature
dependence
Inter instrument
agreement
Repeatability
Measurement/
illumination area
Minimum interval
Between measurements
Measurement time
Light source
Sphere size
Reflectance range
HaIf bandwidth
Wavelength pitch
Wavelength range
Illumination/
Observation system
Light-receiving element
Spectral separation
device
CM-3600d 12 kg, CM-3610d 16.5 kg
CM-3600d 244 x 208 x 378 mm, CM-3610d 300 x 597 x 315 mm
0 to 40°C, relative humidity 80% or less (at 33°C) with no condensation
13 to 33°C, relative humidity 80% or less (at 33°C) with no condensation
AC120V/230V 50/60Hz (Using included AC adapter)
RS-232C, D-SUB 9-pin (female) terminal
Width: 133mm; depth: approx. 50mm; measurement dia.: approx. 17mm
Transmission sample holder (Optional accessory): Sample holder
for both plate-shaped and liquid samples (removable)
400nm cutoff and 420nm cutoff
Instantaneous numerical adjustment
Spectral reflectance: Within ±0.10%/°C
Color difference: Within ∆E*ab 0.05/°C
Mean ∆E*ab0.15 (SCI) Average for 12 BCRA Series II color tiles
compared to values measured with master body.
Spectral reflectance: Standard deviation within 0.1%
Colorimetric values: Standard deviation within ∆E*ab0.02
LAV : ø25.4mm/ø30mm
MAV : ø8mm/ø11mm (Selectable)
SAV : ø4mm/ø7mm
Approx. 5 seconds
Approx. 1.5 seconds
4 pulsed xenon lamps
ø152mm
0 to 200%; resolution: 0.01%
Approx.10nm
10nm
360 to 740nm
Reflectance; di:8°, de:8°(diffused illumination, 8-degree viewing), equipped with
simultaneous measurement of SCI (specular component included) / SCE (specular
component excluded) Conforms to CIE No.15,lSO7724/1,ASTME1164, DIN5033
Teil7 and JIS Z8722 condition C standard. Transmittance : di:0°, de:0°(diffused
illumination, 0-degree viewing) Conforms to CIE No.15, ASTME1164 and DIN5033
Teil7 standard.
Silicon photodiode array (dual 40 elements)
Diffraction grating
*1 Operating temperature/humidity range of products for North America : 13 to 33°C, relative humidity 80% or less (at 31°C) with no condensation
Mac OS 10.3.9J illustrator 10J
CM-3600d/3610d_outside.ai 2007.7.6
SAFETY PRECAUTIONS
Always connect the instrument to the
specified power supply voltage.
Improper connection may cause a
fire or electric shock.
A
H
I
E
P
K
Printed in Japan9242-4868-31
2000 KONICA MINOLTA SENSING, INC.
11
For correct use and for your safety, be sure to read
the instruction manual before using the instrument.
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : YKA 0937154
Registration Date : March 3, 1995
SpectraMagicTM NX enables you to perform comprehensive color
inspection and analysis of incoming raw materials, in process
production, and outbound color critical goods and materials in
virtually any industry. With SpectraMagicTM NX you can insert
digital images with measured data. Measure samples in any of 8
universally accepted color spaces. Select from 15 illuminants, and
up to 40 indices to determine specific color and appearance
properties, such as strength, brightness, haze, yellowness, opacity
and strength. You can even configure up to 3 customized color
equations. Reports range from simple Pass/Fail to trend charts,
histograms, color plots, and spectral graphs. SpectraMagicTM NX
comes with predefined templates using skin technology, or you can
create your own templates. For illustrations and explanations to
understanding color and color measurement technology, there is a
link to Konica Minolta's well known and respected “Precise Color
Communication”. Step by step navigation help.
• Windows®is a trademark of Microsoft Corporation in the USA and
other countries.
Supports Windows®2000/XP/Vista
SpectraMagicTMNX (Optional)
Performance
Fast, simultaneous measurement of Specular Included and Specular
Excluded components (SCI/SCE)
Versatility
Full wavelength range 360-740nm with 10nm pitch
Reliability
CM-3600d and CM-3610d Spectrophotometer:
Highest Quality in Color Measurement
in the Laboratory and for Production
High reliability design with fewest moving parts of any benchtop
spectrophotometer
Large (6") sphere; di:8°, de:8°geometry
Reflectance and transmittance sample measurements
Changeable measurement areas (ø4mm,ø8mm,or ø25.4mm)
View finder design for easy sample viewing
Compact and lightweight
Fast, Instantaneous numerical UV adjustment enables
UV-included, UV-excluded, and UV-adjusted data to be obtained
simultaneously
Precise inter-instrument agreement.
All CM-3600d spectrophotometers meet published inter-instrument
agreement.
Maintenance free technology
and ruggedness concept
The CM-3600d is equipped with maintenance-free technology
and solid state components to withstand rugged conditions.
The monolith polychromator unit assures highest durability and
stability. With one exception (Observing Lens), the CM-3600d
does not use any moving parts. Furthermore, each CM-3600d
passes a hard endurance test program to comply with KONICA
MlNOLTA's highest quality standards in accordance with
ISO-9001.
Compact but yet Powerful
Behind the compact and space-
saving design, you'll
find the skills of a top-
class instrument with
6" large sphere and
other functions so far
only found in much
larger and more
expensive
Full range of application coverage
Konica Minolta Innovative
Optical System Technology
Multiple measurement area selection
For high-accuracy color control
The newly designed Monolith Polychromator Unit
Bright and clear
sample viewing system
Designed to meet your highest
ergonomic expectations
1.Numerical Gloss Control
Enhanced Performance Technology
Konica Minolta Innovative Optical System
2.Numerical UV Control
This technology also provides:
SCI specular component included
SCE specular component excluded
UV-adjusted data
LAV
25.4mm
MAV
8mm
SAV
4mm
Konica Minolta's Innovative Optical System, including
Numerical Gloss Control and Numerical UV Control,
opens the way to unlimited application versatility at a
price level never seen before.
Whatever your sample looks like, with the CM-3600d you can measure it!
Reflectance of opaque samples, Transmittance of transparent liquids or solids and
Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is
truly versatile.
Transmittance Measurement-The CM-3600d employs the d:0°
geometry (diffused lighting, 0°viewing), which conforms to ISO,
DIN, CIE, and ASTM standards.
Reflectance Measurement-The
CM-3600d employs di:8°, de:8°
geometry (diffused lighting, 8°from
normal viewing) which conforms to
JlS7 ISO, DIN, CIE and ASTM
standards.
consists of a diffraction grating with a full wavelength range, 360-740 nm,
at 10nm pitch, and 10nm half-band width, both for sample and reference
light, and dual-channel sensor array.
The retro mirror's reflected and
illuminated sample viewing
screen minimizes fatigue and
allows trouble-free sample
observation.
The compact and space-saving body as well
as all functions of the CM-3600d have been
designed to ensure easy and fatigue-free
operation in daily use. The bright mirror
sample viewing system, the sample holder
for up to A4 size samples with full 90°lock
down, and the versatile Transmittance
chamber for liquid or translucent samples
are all just where you expect them to be for
easy operation.
To cover all kinds of samples, the CM-3600d gives you
the choice among three aperture sizes: LAV 25.4mm,
MAV 8mm and SAV 4mm with precise measurement
spot adjustment by a motorized observing lens.
The CM-3600d and CM-3610d are equipped with Konica Minolta Innovative
Optical System technology. For users, this means high accuracy and
repeatability, improved performance, additional features, simple operation,
and - low, affordable pricing.
Instead of using a mechanically driven gloss trap,
the CM-3600d and CM-3610d feature a patented
numerical Gloss (SCl/SCE) control system.
By sequentially firing two flashes, within a few
seconds the system provides both SCI and SCE
values for each sample.
To replace the time-consuming traditional UV
measurement system that utilizes moving filters,
the CM-3600d introduces yet another patented
numerical calculation system, which is also part
of the CM-3610d: The measured values of two
sequentially fired flashes, one with full UV ener-
gy and one with UV cut-off filter at either 400 or
420 nm are combined to obtain the spectral
characteristics, and the respective whiteness
and tint value of any UV-activated fluorescence
sample. To avoid triplet effect on FWA treated
samples, the CM-3600d and CM-3610d can be
set to Soft-Flash mode. Numerical UV Control
technology makes faster, more effective and
reliable measurements of FWA treated materials
such as textiles, papers and detergents.
Mac OS 10.3.9J illustrator 10J
CM-3600d/3610d_inside.ai 2007.11.15
Personal Computer
Accessory Case
CM-A209
Dust Cover
CM-A110
(CM-3600d)
CM-A118
(CM-3610d)
Opacity Jig
CM-A134
(only CM-3610d)
Spectrophotometer CM-3600d/CM-3610d
Standard accessories Optional accessories
Target Mask
CM-A105
( 25.4mm)
AC Adapter
RS-232C Cable IF-A12
(9-pin, 2m)
White Calibration Plate CM-A103
(with containing calibration data)
Target Mask
CM-A106
( 8mm)
Target Mask
CM-A107
( 4mm)
Cell
CM-A99
(20mm)
Cell
CM-A98
(10mm)
Cell
CM-A97
(2mm)
Plastic Cell
CM-A132
(20mm; set for 100)
Plastic Cell
CM-A131
(10mm; set for 100)
Plastic Cell
CM-A130
(2mm; set for 100)
only CM-3600d
Transmittance.
Zero Calibration Plate
CM-A100
Transmittance
Specimen Holder
CM-A96
Zero Calibration Box
CM-A104
(CM-3600d)
Zero Calibration Box
CM-A119
(CM-3610d)
RS-232C Cables IF-A13
(9-pin, 5m)
Color Tiles
SpectraMagicTM NX
CM-S100w
System
Diagram
Specifications
Network construction for color control either within
an organization or between organizations
Built for Precision,
Priced for Economy
Outstanding Performance through Innovative Technology
CM-3600d Horizontal Spectrophotometer
Highly accurate, reliable and rugged
Versatile instrument for most colorimetric applications
Simplified operation.
CM-3610d Vertical Spectrophotometer for best application support
Speeds up textile and paper measurements
Ideal for non contact measurements such as powders, pigments
Quick sample handling and observation
In-house color control
Color control between companies
R&D
Design Production
Company
A
Company
B
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series
CM-3600d
CM-3610d
CM-3500d
CM-2600d/2500d/2500c
"State of the Art" Reference models
Laboratory and Production Model(horizontal)
Laboratory and Production Model(vertical)
Unique Top Port bench-top model
Top class accuracy portables
CM-3500d
CM-3700d
CM-2000/2600d
series 2500d
CM-3600d
CM-3610d
High inter-instrument agreement between the same Konica Minolta
model and also among all CM models (benchtops and portables):
CM-2000 series, CM-3000 series,
This inter-instrument agreement is ideal when multiple units will be
used for color control either within an organization or between
organizations.
Weight
Size (W x H x D)
Storage temperature/
humidity range
Operating temperature/
humidity range
(*1)
Power
Interface
Transmittance
chamber
UV cut filter
UV adjustment
Temperature
dependence
Inter instrument
agreement
Repeatability
Measurement/
illumination area
Minimum interval
Between measurements
Measurement time
Light source
Sphere size
Reflectance range
HaIf bandwidth
Wavelength pitch
Wavelength range
Illumination/
Observation system
Light-receiving element
Spectral separation
device
CM-3600d 12 kg, CM-3610d 16.5 kg
CM-3600d 244 x 208 x 378 mm, CM-3610d 300 x 597 x 315 mm
0 to 40°C, relative humidity 80% or less (at 33°C) with no condensation
13 to 33°C, relative humidity 80% or less (at 33°C) with no condensation
AC120V/230V 50/60Hz (Using included AC adapter)
RS-232C, D-SUB 9-pin (female) terminal
Width: 133mm; depth: approx. 50mm; measurement dia.: approx. 17mm
Transmission sample holder (Optional accessory): Sample holder
for both plate-shaped and liquid samples (removable)
400nm cutoff and 420nm cutoff
Instantaneous numerical adjustment
Spectral reflectance: Within ±0.10%/°C
Color difference: Within ∆E*ab 0.05/°C
Mean ∆E*ab0.15 (SCI) Average for 12 BCRA Series II color tiles
compared to values measured with master body.
Spectral reflectance: Standard deviation within 0.1%
Colorimetric values: Standard deviation within ∆E*ab0.02
LAV : ø25.4mm/ø30mm
MAV : ø8mm/ø11mm (Selectable)
SAV : ø4mm/ø7mm
Approx. 5 seconds
Approx. 1.5 seconds
4 pulsed xenon lamps
ø152mm
0 to 200%; resolution: 0.01%
Approx.10nm
10nm
360 to 740nm
Reflectance; di:8°, de:8°(diffused illumination, 8-degree viewing), equipped with
simultaneous measurement of SCI (specular component included) / SCE (specular
component excluded) Conforms to CIE No.15,lSO7724/1,ASTME1164, DIN5033
Teil7 and JIS Z8722 condition C standard. Transmittance : di:0°, de:0°(diffused
illumination, 0-degree viewing) Conforms to CIE No.15, ASTME1164 and DIN5033
Teil7 standard.
Silicon photodiode array (dual 40 elements)
Diffraction grating
*1 Operating temperature/humidity range of products for North America : 13 to 33°C, relative humidity 80% or less (at 31°C) with no condensation
Mac OS 10.3.9J illustrator 10J
CM-3600d/3610d_outside.ai 2007.11.15
SAFETY PRECAUTIONS
Always connect the instrument to the
specified power supply voltage.
Improper connection may cause a
fire or electric shock.
A
H
L
F
P
K
Printed in Japan9242-4868-31
2000 KONICA MINOLTA SENSING, INC.
12
For correct use and for your safety, be sure to read
the instruction manual before using the instrument.
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : YKA 0937154
Registration Date : March 3, 1995

This manual suits for next models

1

Other Konica Minolta Measuring Instrument manuals

Konica Minolta VI-9I User manual

Konica Minolta

Konica Minolta VI-9I User manual

Konica Minolta CA-210 User manual

Konica Minolta

Konica Minolta CA-210 User manual

Konica Minolta REGIUS 210 User manual

Konica Minolta

Konica Minolta REGIUS 210 User manual

Konica Minolta CA-410 Series User manual

Konica Minolta

Konica Minolta CA-410 Series User manual

Konica Minolta cm-5 User manual

Konica Minolta

Konica Minolta cm-5 User manual

Konica Minolta CM-3700D User manual

Konica Minolta

Konica Minolta CM-3700D User manual

Konica Minolta SPECTRAMAGIC NX - User manual

Konica Minolta

Konica Minolta SPECTRAMAGIC NX - User manual

Konica Minolta CM3600D User manual

Konica Minolta

Konica Minolta CM3600D User manual

Konica Minolta CA-2500 Series User manual

Konica Minolta

Konica Minolta CA-2500 Series User manual

Konica Minolta AeroDR System User manual

Konica Minolta

Konica Minolta AeroDR System User manual

Konica Minolta CR-10 Plus User manual

Konica Minolta

Konica Minolta CR-10 Plus User manual

Konica Minolta CM-600d User manual

Konica Minolta

Konica Minolta CM-600d User manual

Konica Minolta CM-3700A-U User manual

Konica Minolta

Konica Minolta CM-3700A-U User manual

Konica Minolta CECF-9 User manual

Konica Minolta

Konica Minolta CECF-9 User manual

Konica Minolta CM-26dG User manual

Konica Minolta

Konica Minolta CM-26dG User manual

Konica Minolta CA-310 User manual

Konica Minolta

Konica Minolta CA-310 User manual

Konica Minolta Vivid 910 User manual

Konica Minolta

Konica Minolta Vivid 910 User manual

Konica Minolta REGIUS 110 HQ User manual

Konica Minolta

Konica Minolta REGIUS 110 HQ User manual

Konica Minolta REGIUS 190 User manual

Konica Minolta

Konica Minolta REGIUS 190 User manual

Konica Minolta CHROMA METER CS-200 User manual

Konica Minolta

Konica Minolta CHROMA METER CS-200 User manual

Konica Minolta CS-3000HDR User manual

Konica Minolta

Konica Minolta CS-3000HDR User manual

Konica Minolta CR-400 User manual

Konica Minolta

Konica Minolta CR-400 User manual

Konica Minolta bizhub C3100i User manual

Konica Minolta

Konica Minolta bizhub C3100i User manual

Konica Minolta CM-M6 User manual

Konica Minolta

Konica Minolta CM-M6 User manual

Popular Measuring Instrument manuals by other brands

Klein Tools CL1100 instruction manual

Klein Tools

Klein Tools CL1100 instruction manual

Siemens 5SV8 200-6KK Operating and mounting instructions

Siemens

Siemens 5SV8 200-6KK Operating and mounting instructions

Ohlendorf SF T30V instruction manual

Ohlendorf

Ohlendorf SF T30V instruction manual

Votronic 1256 Installation and operating manual

Votronic

Votronic 1256 Installation and operating manual

X-Rite 552 Getting started

X-Rite

X-Rite 552 Getting started

JUMO LOGOSCREEN 500 operating instructions

JUMO

JUMO LOGOSCREEN 500 operating instructions

sauter TPE-N instruction manual

sauter

sauter TPE-N instruction manual

DAKOTA ULTRASONICS Z-303-0001 Operation manual

DAKOTA ULTRASONICS

DAKOTA ULTRASONICS Z-303-0001 Operation manual

SIGRIST AquaMaster instruction manual

SIGRIST

SIGRIST AquaMaster instruction manual

PHYWE Cobra SMARTsense Potassium Ion operating instructions

PHYWE

PHYWE Cobra SMARTsense Potassium Ion operating instructions

Electro-Sensors SG1000A manual

Electro-Sensors

Electro-Sensors SG1000A manual

Viavi CellAdvisor 5G user guide

Viavi

Viavi CellAdvisor 5G user guide

Fluke iFlex i2500-18 Quick reference card

Fluke

Fluke iFlex i2500-18 Quick reference card

EMKOMETER EMKOTDR-60 manual

EMKOMETER

EMKOMETER EMKOTDR-60 manual

Hama 00108834 Operating	 instruction

Hama

Hama 00108834 Operating instruction

Graco HG6000 Instructions and parts manual

Graco

Graco HG6000 Instructions and parts manual

THORLABS INT-COM-1300 Operation manual

THORLABS

THORLABS INT-COM-1300 Operation manual

Keysight Technologies E4980A Quick demo guide

Keysight Technologies

Keysight Technologies E4980A Quick demo guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.