manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. KSB
  6. •
  7. Water Pump
  8. •
  9. KSB DOMI User manual

KSB DOMI User manual

INSTRUCTION MANUAL
DOMI, CLAS, DREX, S, BPU, CLASVORT, VX, VORTIX, CANAL, STONE, TRITUR, D4, D6
SUBMERSIBLE PUMPS MIF-6100/02-I
01-09-05
1. RECEIPT
When you receive the equipment, check that the packaging
is in good conditions. If not, indicate this in writing on the
carrier’s delivery note. Unpack the equipment and verify its
state. If there is damage, inform the dealer immediately.
2. SAFETY INSTRUCTIONS
In this manual, the important safety instructions are
specifically marked. These marks have the following
symbols:
Safety instructions whose lack of fulfilment could affect
the safety of people and installations.
Safety instructions to prevent electrical risks
(hydrocution, ...)
Safety instructions whose lack of fulfilment could
affect the equipment and its operation.
All the equipment supplied by BOMBAS ITUR are
properly protected to prevent possible accidents, but in
any case all the safety recommendations indicated on
the pump, on all the documents supplied with it or in
applicable regulations, must be followed.
Failure to comply with these instructions exempts BOMBAS
ITUR S.A. from any responsibility.
The safety recommendations indicated are based on our
experience and on normal use of the equipment.
The installer/user is exclusively responsible for assessing
the individual risks that exist in each installation and for not
permitting its connection and start up without the
appropriate protections.
3. GENERAL COMMENTS
The user must not carry out operations that are not
permitted in this manual. Any operation or handling
must always be carried out with the appropriate means,
by duly qualified personnel and after having read and
understood this manual.
Any installation, maintenance, repair or transport
operations must be carried out with the pump stopped
and safely disconnected.
The correct state of both the electrical system and
pipes must be verified on a regular basis. If their state
is not safe, the pump must be stopped and repaired.
This is especially important if the defects are located in
electrical devices or cables.
When starting the equipment up, by activating the
switch or connecting it to a socket, make sure that this
is done on a dry floor, and never with wet hands and/or
without proper footwear.
Before starting the pump up, all its elements, especially
those that affect safety, must be correctly installed and
fastened. Never start the pump up when there are
people close to it.
Never use the power cable or the discharge tube as a
means of elevating or supporting the pump. A metal
cable or chain must be fitted, suitable for the weight,
attached to the handle or hooks prepared for this.
4. LOCATION
Access to the pump or installation must be sufficiently
restricted, so that nobody can inadvertently access it.
Safety elements must be placed that prevent the entry
of children or other risk people. Never remain in the
area where the pump is placed whilst it is in operation.
The pump, except those specifically designed for this,
must NOT be installed in places classified as having an
explosion risk.
if the pump is outdoors and there is a risk of frost,
it must be completely submerged and operating.
Never let the ice affect it, or let ice form on the inside.
If the pump is not going to be used for a long period of
time, it must be cleaned and stored in a dry and
ventilated place.
If the pump is in a well or pit, before carrying out any
operation, verify that there are no poisonous,
suffocating or explosive gases. If you are going to use
a blower or fan to evacuate the gases, verify that this
does not represent a risk of explosion. Whilst the pit is
open, place protections to prevent accidental falls.
If the bottom of the area where the pump is going
to be place is sandy or muddy, the pump must be
suspended using adequate means, or placed on a
sufficient base, to prevent it from sinking.
If the pumps are going to be used in swimming pools,
gardens or similar places, European Regulation 60335,
Section 2, protection class 1, must be complied with.
Check with a specialist.
5. LIQUID PUMPED
The pumps must never work dry.
The pumps referred to in this manual, have been
designed for use under the conditions indicated in the
catalogue, pump and applicable documents.
In any case, and as a general rule, the liquid pumped must
NOT be:
WARNING
WARNING
WARNING
WARNING
MIF-6100/02-I
2
•Aggressive, corrosive, inflammable, toxic or explosive.
•Have a higher temperature than that indicated as
maximum for each model.
•Incompatible with the pump materials.
The presence of long or fibrous solids must be
avoided in all those pumps that have a grid,.
6. INSTALLATION
Both the user and the installer must strictly follow all
applicable safety standards, laws and regulations.
The prescriptions of DIN-1986 or applicable local
regulations must be followed in waste and faecal water
installations.
Place a control and isolating valve next to the pump in the
discharge pipe, and after it a retaining valve. Check that
the valves are suitable for the liquid to be pumped.
S-Series pumps must be suspended 10 cm from
the bottom at the least, and the liquid level must never
be less than 15 cm over the grid.
D4 and D6 series pumps must be suspended 150
cm from the bottom at the least and the liquid level
must never be less than 15 cm over the grid. These
pumps must not be installed in wells with sand, sludge
or abrasive particles in the water to be pumped.
The fluid entering the pump must be prevented
from entering directly onto the pump or the float.
If the pump is going to be activated automatically
with a float, the difference in heights between start and
stop must be sufficient so as not to produce
excessively continued starts. In any case the free
cable length must never be less than 10 cm.
7. ELECTRICAL INSTALLATION
The electrical connections must be carried out by
qualified personnel and meticulously observing all the
standards and recommendations to prevent accidents.
The earth tapping cables must be the first to be
connected and the last to be disconnected.
If an extension is going to be added to the cable, verify
that the type and section of the cable are suitable, and
that the splice is done correctly and hermetically.
The characteristics of the mains (voltage, frequency,
etc) must correspond to the values indicated on the
characteristics plate. A variation in voltage of up to 10
% is admissible.
An unbalance between phases of up to 5% is admissible. If
higher values are observed, check the values with the other
connection combinations of the cables (not varying the
rotation direction). If the highest value always occurs in the
same phase of the line, the cause of the unbalance is
mainly in the mains.
The electrical installation must have:
•A suitable earth tap.
•An omnipole disconnection system (for all the
phases) with contact opening of at least 3 mm
separation.
•A high sensitivity differential switch (0.03 A).
•If the motor does not have thermal protection,
protection must be installed on the panel.
•The power cable must be at least type H07 RN-F
according to VDE 0250 (DIN-57282, DIN-57245).
The use of small-sized or low quality components
in the electrical installation will provoke a rapid
deterioration in the contacts, with the subsequent
deterioration in the motor, due to unbalance in the
power supply.
In those single-phase pumps that do not
incorporate a capacitor, this must be installed on the
control panel.
Verify, if the pump works outdoors, that the
applicable electrical regulations and standards are
complied with. In some countries it may be necessary
to supply the pump through a transformer (220 V).
If the connection is made with a plug or similar,
the current tap must be safe and be located in a place
protected from flooding.
8. START-UP
Before starting the pump up, check that all the safety and
protection elements are correctly installed and fastened.
Make the pump turn manually, to break any adherence.
Totally open the discharge valve. Submerge the pump and
place it in its operating position. Partially close the
discharge valve
(Only three-phase pump). Check that the direction of
rotation is correct. To do so, start the pump up for a few
seconds. Exchange two of the phases and start the pump
up again. The configuration, where the flow/pressure
supplied by the pump are greater, is the adequate one.
Start the pump up. Check that no incorrect operating
symptoms, such as excessive noises or vibrations, appear.
9. MAINTENANCE
From time to time check that both the float (if there is one)
and the grid and/or runner are clean. If they are not,
proceed to clean them. Any other type of maintenance
operation, especially those referring to the motor, must be
carried out by personnel from BOMBAS ITUR, or its
authorised technical services. For D4 and D6 series, this
maintenance is not necessary as these always work with
clean water.
If oil leaks are detected in the pump, stop it
immediately and notify the authorised technical service.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
MIF-6100/02-I 3
This page has deliberately been left blank
BOMBAS ITUR, S.A. (KSB Group)
P.O. Box 41 – 20800 ZARAUTZ (Gipuzkoa) Spain
Tel.: +34 943 899 899 – Fax +34 943 130 710
E-mail: [email protected] – www.itur.es
MIF-6100/02-I
10. ANOMALIES IN THE OPERATION
1) The pump does not start.
2) The pump starts but does not give pressure.
3) The pump stops and starts continuously.
4) The pump starts but does not give flow volume
5) The motor heats up too much.
6) The rotor turns with difficulty.
7) Excessive noises or vibrations.
1 2 3 4 5 6 7 POSSIBLE CAUSES SOLUTIONS
X X
Pressure generated by the pump is less than that required by the
installation Check head losses and geometric height
X X X
Inappropriate aspiration Improve aspiration. Check height of pump above floor, and state
of grid.
X X Density or viscosity of liquid Change pump for another suitable one
X X Insufficient pipe diameters Install pipes with larger diameter
X X X Air gets in Check regulation of levels in the well
X X X X Bearings wornº Go to an official technical service
X X X Pressure required less than that supposed Regulate discharge valve
X X X Bad priming Lift and submerge pump again
X X Pipe obstruction Clean pipes
X X X X X X Obstruction inside the pump Proceed to clean grid/runner
X Incorrect direction of rotation Change motor connections
X X X X Badly regulated discharge valve Regulate correctly
X Supply, fuses the thermals disconnected Connect them reset them
X X Badly regulated float Regulate float
11. GUARANTEES
Failure to comply with the indications given in this manual means using the equipment incorrectly, from the technical and
safety viewpoint. Therefore this EXEMPTS BOMBAS ITUR FROM ANY RESPONSIBILITY IN THE CASE OF PERSONAL
ACCIDENTS OR MATERIAL DAMAGE, AND IT ALSO GIVES RISE TO THE LOSS OF ANY RIGHT TO CLAIM UNDER
GUARANTEE.
A one-year guarantee is established against any project or manufacturing defect. Transport of the equipment to our facility or
to that of our agreed technical services is on the customer’s account as well as travelling expenses of our personnel to the
facility, if required.
Any handling of the equipment by the customer, without our written consent, means the loss of any right to claim under
guarantee.
"CE" DECLARATION OF APPROVAL
BOMBAS ITUR, S.A. herewith declares, on its own responsibility, that the above-mentioned products, which it
manufactures (if supplied with an engine), and to which this Declaration is related, meets that set down in European
Directives 98/37/CE, 89/336/CEE, 73/23/CEE on the laws of approximation of Member States with respect to machines.
Harmonised rules applied:
EN 292 Part 1 and EN 292 Part 2.
ZARAUTZ, 21/02/2006
Position: President
Name: Juan Antonio Uriarte

This manual suits for next models

12

Other KSB Water Pump manuals

KSB RWCN Operation instructions

KSB

KSB RWCN Operation instructions

KSB UPAchrom CC Installation instructions

KSB

KSB UPAchrom CC Installation instructions

KSB Amarex KRT Installation instructions

KSB

KSB Amarex KRT Installation instructions

KSB RPHb User manual

KSB

KSB RPHb User manual

KSB Ama-Drainer 4 Series Installation instructions

KSB

KSB Ama-Drainer 4 Series Installation instructions

KSB Amacan P 700-470 Installation instructions

KSB

KSB Amacan P 700-470 Installation instructions

KSB Rio-Therm N SL Installation instructions

KSB

KSB Rio-Therm N SL Installation instructions

KSB Amarex KRT User manual

KSB

KSB Amarex KRT User manual

KSB Amacan P 500-270 Installation instructions

KSB

KSB Amacan P 500-270 Installation instructions

KSB INVCP Operation instructions

KSB

KSB INVCP Operation instructions

KSB Amarex KRT Installation instructions

KSB

KSB Amarex KRT Installation instructions

KSB Ama-Drainer 4 Series Installation instructions

KSB

KSB Ama-Drainer 4 Series Installation instructions

KSB Delta Primo F User manual

KSB

KSB Delta Primo F User manual

KSB Etanorm V User manual

KSB

KSB Etanorm V User manual

KSB Ixo N User manual

KSB

KSB Ixo N User manual

KSB Trialine Installation instructions

KSB

KSB Trialine Installation instructions

KSB Omega Installation instructions

KSB

KSB Omega Installation instructions

KSB moviBOOST VP User manual

KSB

KSB moviBOOST VP User manual

KSB Calio S Installation instructions

KSB

KSB Calio S Installation instructions

KSB HPK Series Installation instructions

KSB

KSB HPK Series Installation instructions

KSB Calio SI Series Installation instructions

KSB

KSB Calio SI Series Installation instructions

KSB Riotec Series User manual

KSB

KSB Riotec Series User manual

KSB Amarex N series User manual

KSB

KSB Amarex N series User manual

KSB Movitec VCI Installation instructions

KSB

KSB Movitec VCI Installation instructions

Popular Water Pump manuals by other brands

GPro RO35-115AD owner's manual

GPro

GPro RO35-115AD owner's manual

arbo SealPro Series user manual

arbo

arbo SealPro Series user manual

IKA Vacstar control operating instructions

IKA

IKA Vacstar control operating instructions

Graco SaniForce 1040e repair parts

Graco

Graco SaniForce 1040e repair parts

Zoeller Basement Sentry Series manual

Zoeller

Zoeller Basement Sentry Series manual

Edwards XDS Series instruction manual

Edwards

Edwards XDS Series instruction manual

RAASM 900 Series manual

RAASM

RAASM 900 Series manual

Hayward HCP2500VSP owner's manual

Hayward

Hayward HCP2500VSP owner's manual

Wilo Drain TM 32 Installation and operating instructions

Wilo

Wilo Drain TM 32 Installation and operating instructions

Graco Dura-Flo 2400 Instructions-parts list

Graco

Graco Dura-Flo 2400 Instructions-parts list

IWAKI PUMPS ES-B Series instruction manual

IWAKI PUMPS

IWAKI PUMPS ES-B Series instruction manual

Nakayama PRO NP1010 manual

Nakayama

Nakayama PRO NP1010 manual

SPX FLOW F2P10-19 instruction manual

SPX

SPX FLOW F2P10-19 instruction manual

Ekin Endustriyel GemmeCotti HTM Series user guide

Ekin Endustriyel

Ekin Endustriyel GemmeCotti HTM Series user guide

AIRMAC DBM80 Series Service manual

AIRMAC

AIRMAC DBM80 Series Service manual

LEYBOLD TURBOLAB 80 operating instructions

LEYBOLD

LEYBOLD TURBOLAB 80 operating instructions

AMT 3931-99 Specifications information and repair parts manual

AMT

AMT 3931-99 Specifications information and repair parts manual

Carel humiFog Touch installation manual

Carel

Carel humiFog Touch installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.