manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. KYORITSU
  6. •
  7. Test Equipment
  8. •
  9. KYORITSU 8031 User manual

KYORITSU 8031 User manual

Incoming supply
Interior wiring
CAT.Ⅰ
Socket
CAT.Ⅱ
CAT.Ⅱ
Equipment
Distribution Board CAT.Ⅲ
Socket
CAT.Ⅳ
#
WARNING
●Read through and understand instructions contained in this
manual before starting using the instrument.
●Save and keep the manual handy to enable quick reference
whenever necessary.
●Be sure to use the instrument only in its intended applications
and to follow measurement procedures described in the
manual.
●Be sure to understand and follow all safety instructions
contained in the manual. Failure to follow the above
instructions cause injury instrument damage and/or damage
to equipment under test.
The symbol
#
Indicated on the instrument means that the user
must refer to related parts in the manual for safe operation of the
instrument. Be sure to carefully read instructions following each
#
Symbol in this manual.
#
WARNING is reserved for conditions and actions that can
cause serious or fatal injury.
#
CAUTION is reserved for conditions and actions that can
cause injury or property damage.
Following symbols are used on the instrument and in the
instruction manual. Attention should be paid to each symbol to
ensure your safety.
Refer to this instructions in the manual.
#
This symbol is marked where the user must refer to the instruction
manual so as not to cause personal injury or instrument
damage.
Indicates an instrument with double or reinforced insulation.
#
WARNINGS
1. Never open the instrument when making measurements.
2. If the instrument shows the following conditions, do not try to
make measurements and have the instrument checked for
inspection or repair.
a) Instrument shows visual damage.
b) Test leads are damaged.
c) Instrument can not be operated for intended measurements.
d) Instrument has been stored for a long period of time
under abnormal conditions.
e) Instrument has been subjected to severe shocks and
vibrations.
3. High voltage may be present with high energy levels.
Connect the leads to the system carefully with fingers behind
all finger guards.
4. If the all open phase lamps are not lit on, any phase may still
be live-be carefull.
#
CAUTIONS
1. Make sure to never apply a voltage more than 600V ACrms.
between the test leads of the instrument and earth to avoid
damage to the instrument.
2. Do not measure for more than five minutes when measuring
on 500V AC or more, although the instrument is designed for
the use 110V through 500V AC.
Measurement categories (Over-voltage categories)
To ensure safe operation of measuring instruments, IEC61010
establishes safety standards for various electrical environments,
categorized as CAT.Ⅰto CAT.Ⅳ, and called measurement
categories. Higher-numbered categories correspond to
electrical environments with greater energy, So a measuring
instrument designed for CAT.Ⅲenvironments gives greater
protection than one designed for CAT.Ⅱ.
C AT. Ⅰ: Equipment connected to a mains outlet socket
C AT. Ⅱ: Fault category level at a mains socket
C AT. Ⅲ: Fault category at distribution board level
C AT. Ⅳ:
The circuit from the service drop to the power meter and
primary over-current protection device (distribution
panel).
FEATURES
●Two Functions in One Unit
 KEW8031F is designed to check phase sequence. Lamps
provided on the unit will also tell you if a phase is open.
●Highly Reliable
 Can check a wide range of 3-phase power source from 110V to
500V. Sealed against dust, the unit ensures trouble-free
performance.
INSTRUCTION MANUAL
PHASE ROTATION TESTER
MODEL8031
DESIGNATIONS
SAFETY WARNINGS
This instrument has been designed and tested according to IEC
Publication 61010; Safety Requirements for Electronic Measuring
Apparatus. This Instruction manual contains warnings and
safetyrules which must be observed by the user to ensure safe
operation of the instrument and retain it in safe condition.
Therefore, read through these operating instruction before using
the instrument.
The voltage values used in this manual or on the meter are given
in line voltage, unless otherwise specified.
(3) Make sure that all of the three lamps for phase check are on.
If so, there is no open phase. When any of the three lamps is
Not on there is open phase.
Open phase check Open phase on terminal
Lamp "L1" is not on where Red alligator clip
is connected.
Open phase check Open phase on terminal
Lamp "L2" is not on where Whight alligator clip
is connected.
Open phase check Open phase on terminal
Lamp "L3" is not on where Blue alligator clip
is connected.
*When the open phase check lamps are not on the rotating disc
does not turn.
(4) Check the rotating direction of the inside disc through the
phase sequence indication window.
*When the rotating disc turns counter-clockwise alternate the
connection of the two of the three alligator clips. Then, the
rotating disc will turn clockwise.
*When the rotating disc turns clockwise phase sequence is
L1,L2 and L3 in order of the power source terminals where the
Red, Whight and Blue alligator clips are connected.
Please Note : New European harmonized phase colours are
as follows.
Red = Brown   Protective Earth = Green yellow
Whight = Black  Neutral = Blue
Blue = Grey
10-1192-1400B
●Functional Design
 Small, Lightweight and portable. Designed for maximum ease of
operation and ruggedness.
●Safety Design
 No exposed metal parts. Safety features are incorporated
including the instant push button switch operation.
SPECIFICATIONS
Standard : IEC 61010-1 CAT.Ⅲ300V Pollution degree 2
IEC 61557-1,7
Voltage : 110V to 500V
Frequency : 50Hz / 60Hz
Withstand Voltage : 5,550V AC for one minute
Time Limit for Continuous Use : Within 5 minutes in case voltage
is above 500V.
Dimensions : 106 (L) x 75 (W) x 40 (D) mm
Weight : Approx. 350g
Accessories : Instruction Manual, Carrying Case
IP cord : IP30 (IEC60529)
OPERATING INSTRUCTIONS
(1) Connect colour coded alligator clips or prods to the terminals
of a 3-phase power source where a rotating electrical machine
such as a motor will be connected or input to a building.
(2) Press the push switch button located on top of the unit.
Keep this button pressed during phase sequence or open
phase check. When the push switch button is released it
immediately goes off.

Other KYORITSU Test Equipment manuals

KYORITSU KEW 8146 User manual

KYORITSU

KYORITSU KEW 8146 User manual

KYORITSU 3021A User manual

KYORITSU

KYORITSU 3021A User manual

KYORITSU 4118A User manual

KYORITSU

KYORITSU 4118A User manual

KYORITSU 8035 User manual

KYORITSU

KYORITSU 8035 User manual

KYORITSU KEW 4105A User manual

KYORITSU

KYORITSU KEW 4105A User manual

KYORITSU PACKTEST Glucose User manual

KYORITSU

KYORITSU PACKTEST Glucose User manual

KYORITSU 6050 User manual

KYORITSU

KYORITSU 6050 User manual

KYORITSU KEW 6010B User manual

KYORITSU

KYORITSU KEW 6010B User manual

KYORITSU KEW SNAP 2434 User manual

KYORITSU

KYORITSU KEW SNAP 2434 User manual

KYORITSU 3165 User manual

KYORITSU

KYORITSU 3165 User manual

KYORITSU 3321A User manual

KYORITSU

KYORITSU 3321A User manual

KYORITSU 6010A User manual

KYORITSU

KYORITSU 6010A User manual

KYORITSU KEW6024PV User manual

KYORITSU

KYORITSU KEW6024PV User manual

KYORITSU KEW 6016 User manual

KYORITSU

KYORITSU KEW 6016 User manual

KYORITSU 3132A User manual

KYORITSU

KYORITSU 3132A User manual

KYORITSU KEW 3127 User manual

KYORITSU

KYORITSU KEW 3127 User manual

KYORITSU KEW3125A User manual

KYORITSU

KYORITSU KEW3125A User manual

KYORITSU 3131A User manual

KYORITSU

KYORITSU 3131A User manual

KYORITSU KEW FORK User manual

KYORITSU

KYORITSU KEW FORK User manual

KYORITSU KEW 3022 User manual

KYORITSU

KYORITSU KEW 3022 User manual

KYORITSU kew 4300 User manual

KYORITSU

KYORITSU kew 4300 User manual

KYORITSU KEW3431 User manual

KYORITSU

KYORITSU KEW3431 User manual

KYORITSU KEW4105DL User manual

KYORITSU

KYORITSU KEW4105DL User manual

KYORITSU 8128 User manual

KYORITSU

KYORITSU 8128 User manual

Popular Test Equipment manuals by other brands

Wiltron 560-9 Series Operation and maintenance manual

Wiltron

Wiltron 560-9 Series Operation and maintenance manual

Datacolor Spyder 5 quick start guide

Datacolor

Datacolor Spyder 5 quick start guide

GRDIAN Charger Plus user manual

GRDIAN

GRDIAN Charger Plus user manual

Dräger Alcotest 6820 Technical manual

Dräger

Dräger Alcotest 6820 Technical manual

Viavi T-BERD/MTS-5800 OCC-4056C Quick Card

Viavi

Viavi T-BERD/MTS-5800 OCC-4056C Quick Card

Larson Davis CAL291 Technical reference manual

Larson Davis

Larson Davis CAL291 Technical reference manual

Hameg HMO Series manual

Hameg

Hameg HMO Series manual

Datamars BLUESTICK quick start guide

Datamars

Datamars BLUESTICK quick start guide

ATC GTDHR FIRST Operating and maintenance instructions

ATC

ATC GTDHR FIRST Operating and maintenance instructions

Medoc Q-Sense Service reference manual

Medoc

Medoc Q-Sense Service reference manual

Webasto 22615 instructions

Webasto

Webasto 22615 instructions

Triplett LVPro20 instruction manual

Triplett

Triplett LVPro20 instruction manual

HTC DIT-90 manual

HTC

HTC DIT-90 manual

Keysight ixia UHD100T32 Getting started guide

Keysight

Keysight ixia UHD100T32 Getting started guide

Keysight N5990A-155 user guide

Keysight

Keysight N5990A-155 user guide

DGC DHT-400PLUS instruction manual

DGC

DGC DHT-400PLUS instruction manual

Tektronix P6458 instructions

Tektronix

Tektronix P6458 instructions

MERCATOR FRM97 Installation and operation instruction book

MERCATOR

MERCATOR FRM97 Installation and operation instruction book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.