Lantronix SI-IES-111D-LRT User manual

SI-IES-111D-LRT and SI-IES-121D-LRT
Unmanaged Hardened PoE+ Injector/Converter
User Guide
Part Number 33585
Revision L June 2022

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 2of 25
Intellectual Property
© 2022 Lantronix, Inc. All rights reserved. No part of the contents of this publication may be
transmitted or reproduced in any form or by any means without the written permission of
Lantronix.
Lantronix is a registered trademark of Lantronix, Inc. in the United States and other countries.
All other trademarks and trade names are the property of their respective holders.
Patented: https://www.lantronix.com/legal/patents/; additional patents pending.
Warranty
For details on the Lantronix warranty policy, go to http://www.lantronix.com/support/warranty.
Contacts
Lantronix Corporate Headquarters
7535 Irvine Center Drive
Suite100
Irvine, CA 92618, USA
Toll Free: 800-526-8766
Phone: 949-453-3990
Fax: 949-453-3995
Technical Support
Phone: Tel: +1 (800) 526-8766, Tel: +1 (949) 453-3990
Email: https://www.lantronix.com/technical-support/
Sales Offices
For a current list of our domestic and international sales offices, go to the Lantronix web site
at www.lantronix.com/about/contact.
Disclaimer
All information contained herein is provided “AS IS.” Lantronix undertakes no obligation to
update the information in this publication. Lantronix does not make, and specifically disclaims,
all warranties of any kind (express, implied or otherwise) regarding title, non-infringement,
fitness, quality, accuracy, completeness, usefulness, suitability or performance of the
information provided herein. Lantronix shall have no liability whatsoever to any user for any
damages, losses and causes of action (whether in contract or in tort or otherwise) in
connection with the user’s access or usage of any of the information or content contained
herein. The information and specifications contained in this document are subject to change
without notice.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 3of 25
Revision History
Date Rev Comments
5/4/17 H Add MTBF and clarify specs.
8/10/17 I Add Max Frame Size.
7/13/20 J Update features, specifications, certifications, and DoC.
9/28/21 K Update DoC, DIN-rail bracket, and Wall Mount bracket.
6/10/22 L Initial Lantronix re-brand.
FCC Warning
This Equipment has been tested and found to comply with the limits for a Class-A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy. It may cause harmful
interference to radio communications if the equipment is not installed and used in
accordance with the instructions. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
•Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 4of 25
Table of Contents
1Overview ............................................................................................................ 5
Product Description ............................................................................................................ 5
Ordering Information........................................................................................................... 5
Features.............................................................................................................................. 5
Packing List......................................................................................................................... 6
Safety Precaution ............................................................................................................... 6
Product Views ..................................................................................................................... 6
2 Hardware Description .......................................................................................... 7
Front Panel ......................................................................................................................... 7
Top View ............................................................................................................................. 7
Grounding ........................................................................................................................... 8
DIP Switch .......................................................................................................................... 8
Ports.................................................................................................................................... 9
Cabling.............................................................................................................................. 10
Wiring the Power Inputs.................................................................................................... 13
LED Indicators .................................................................................................................. 14
3Mounting .......................................................................................................... 15
DIN-Rail Mounting ............................................................................................................ 15
Wall Mounting (Optional) .................................................................................................. 16
4Troubleshooting ............................................................................................... 18
Specifications.................................................................................................................... 19
Power Supply Specifications ............................................................................................ 21
25131 Features and Specifications ............................................................................... 21
25130 Features and Specifications ............................................................................... 22
Declaration of Conformity ................................................................................................. 24

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 5of 25
1 Overview
Product Description
The SI-IES-111D-LRT is a 2-port unmanaged hardened PoE+ injector/converter that adds up to 30
Watts of power from its PoE+ Port onto a network segment. The gigabit speed SFP slot provides
the ultimate flexibility by allowing fiber SFP uplink ports with varying communication distances.
The SI-IES-121D-LRT is a 3-port unmanaged hardened PoE+ injector/converter that adds up to
30 Watts of power from its (2) PoE+ ports onto 2 network segments. The gigabit speed SFP slot
provides the ultimate flexibility by allowing fiber SFP uplink ports with varying communication
distances.
Ordering Information
SKU
Description
SI-IES-111D-LRT
(1) 100/1000Base-X SFP slot + (1) 10/100/1000Base-T PoE+ port
SI-IES-121D-LRT
(1) 100/1000Base-X SFP port + (2) 10/100/1000Base-T PoE+ ports
Optional Accessories (sold separately)
SFP Modules
See the Lantronix relevant SFP Modules page
25130
Industrial Power Supply for SI-IES-111D-LRT. Input: 88-264VAC, 120-370
VDC. Output: 48-55VDC, 0.83A, 39.8 Watts
25131
Industrial Power Supply for SI-IES-121D-LRT. Input: 85-264VAC, 120-370
VDC. Output: 48-55VDC, 1.6A, 76.88 Watts
OCA-P181610
18x16x10” Polycarbonate Enclosure
Features
•IEEE 802.3at PoE+ to supply 30 Watts on 10/100/1000Base-T port (SI-IES-111D-LRT)
•IEEE 802.3at PoE+ to supply 30 Watts per port on 10/100/1000Base-T ports (SI-IES-121D-
LRT)
•Supports IEEE 802.3af
•Supports dual speed for SFP slot
•Compact, space saving size
•IP31 housing protection
•Link Pass Through
•Extended operating temperature (-40°C to +75°C)
•DIN Rail mount / optional wall mount brackets included
•Full/half-duplex flow control
•Auto-MDI/MDIX
•Auto-Negotiation
•10K byte jumbo frames

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 6of 25
Packing List
•One Hardened Injector/ Converter with IEEE 802.3af/IEEE 802.3at PSE
•One Documentation Postcard
•One DIN-rail Clip
•Two Wall Mounting Brackets and Screws
Safety Precaution
If DC voltage is supplied by an external power supply, you must use an isolated power supply.
Product Views

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 7of 25
2 Hardware Description
This section provides product views, grounding, wiring, LED, DIP switch, and cabling information.
Front Panel
The SI-IES-111D-LRT and SI-IES-121D-LRT front panels are shown below.
Hardened PoE+ Devices Front Panels
Top View
Consistent with the IP31 rating, the terminal block connector for the DC power input is located on
the bottom of the device.
Top Panel of the Hardened PoE+ Devices

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 8of 25
Grounding
After the Injector is mounted and connected, the back panel grounding
screw can be used for grounding. Grounding and wire routing help limit the
effects of noise due to electromagnetic interference (EMI).
Note: Run the ground connection from the ground screw to the grounding
surface before connecting devices.
Caution: Avoid Improper Grounding
Required:
Isolated DC Supply
Connect chassis to earth ground
Do not connect earth ground to:
Negative input terminal
Positive input terminal
DIP Switch
The front panel DIP Switch is used to configure the SFP operating speed. The default position is
Mode 2, 1000M.
DIP Switch Definition
Status Description
Mode 1 100M
Mode 2 1000M
The SFPs are hot-swappable. However, you must cycle device power
whenever the DIP switch is changed (i.e., whenever changing SFP mode/speed).

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 9of 25
Ports
RJ45 ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or
1000Base-T device connections. Auto MDI/MDIX means that you can connect to another switch or
workstation without changing straight through or crossover cabling. See information below for
straight through and crossover cable PIN assignments.
RJ-45 Pin Assignments
Pin Number
Assignment
1
Tx+
2
Tx-
3
Rx+
6
Rx-
Note: The “+” and “-” signs represent the polarity of the wires that make up each wire
pair.
All ports on this Hardened PoE injector support automatic MDI/MDI-X operation, so you can use
straight-through cables (see below) for all network connections to PCs, servers, or to other switches
or hubs. In straight-through cables, pins 1, 2, 3, and 6, at one end of the cable, are connected
straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below shows the
10BASE-T/ 100BASE-TX /1000Base-T MDI and MDI-X port pin outs.
Pin MDI-X Signal Name MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 10 of 25
Signals for 1000Base-T
Pin Signal name
Signal definition
1 TRD+(0)
Transmit and receive data 0 (positive lead)
2 TRD-(0)
Transmit and
receive data 0 (negative lead)
3 TRD+(1)
Transmit and receive data 1 (positive lead)
4 TRD+(2)
Transmit and receive data 2 (positive lead)
5 TRD-(2)
Transmit and receive data 2 (negative lead)
6 TRD-(1)
Transmit and receive data 1 (negative lead)
7 TRD+(3)
Transmit and receive data 3 (positive lead)
8 TRD-(3)
Transmit and receive data 3 (negative lead)
Cabling
A twisted-pair segment can use unshielded twisted pair (UTP) or shielded twisted pair (STP)
cabling. The cable between the powered device and the injector must be less than 100 meters
(328 ft.) long and comply with the IEEE 802.3ab 1000Base-T standard for Category 5e or above.
The Fiber segment using a single-mode connector type must use 9/125μm single-mode fiber
cable. You can connect two devices at a distance of 10 km. Fiber segment using multi-mode
connector type must use 50/125 or 62.5/125μm multi-mode fiber cable. You can connect two
devices at a distance of 550m.
The small form-factor pluggable (SFP) is a compact optical transceiver used in optical
communications for both telecommunication and data communication applications.
See the Lantronix SFP web page for more small form factor pluggable (SFP) transceivers
information.
Refer to the SFP manual for important safety information.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 11 of 25
To connect the SFP transceiver and LC cable, follow the steps shown below:
1. Insert the transceiver into the SFP module. Notice that the triangle mark is the bottom of the
module.
Transceiver to the SFP module
Transceiver Inserted
2. Insert the LC connector of the fiber cable into the SFP transceiver.
LC connector to the SFP transceiver

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 12 of 25
To remove the LC connector from the SFP transceiver, follow the steps below:
1. Press the upper side of the LC connector from the transceiver and pull it out to release.
Remove LC connector
2. Push down on the metal loop and pull the transceiver using the metal loop.
Pull out from the SFP module

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 13 of 25
Wiring the Power Inputs
Follow the steps below to insert the power wire.
1. Locate the labeling on the device indicating the location of V+ and V- power input connections
on the device.
2. Insert the positive and negative wires into the V+ and V- contacts on the terminal block
connector.
3. Tighten the wire-clamp screws on the terminal block, highlighted in red above, to secure the
wire connections.
Note: The wire gauge for the terminal block should be 12~ 24 AWG.
Note: Adjust the power supply as required. These devices accept 48~57VDC; higher voltage
(50~57VDC) may be required for some high powered PD loads.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 14 of 25
LED Indicators
The front panel LEDs display power status and network status.
Each LED state and color has its own specific meaning as defined in the table below.
LED Definitions
LED Indicator Label Description
System Power PWR Off Power off
Solid Green Power on
PoE Power PoE Off No PoE power output
Solid Green PoE power output OK
RJ-45
Giga
Solid Amber
Link to 1000M bps network
Off
Not connected to network or not working
at speed of 1000M
Link/ACT
Solid Green Connected to network
Blinking Green Networking is active
Off Not connected to network
SFP Link/ACT
Off No SFP connection detected
Solid Green When there is a secure SFP connection
Blinking Green
When there is transmission or reception
of data occurring at speed of
100/1000Mbps

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 15 of 25
3 Mounting
DIN-Rail Mounting
The DIN-rail clip is screwed onto the SI-IES-1x1D-LRT when built at the factory. If the DIN-rail clip is
not installed, see the figure below to install the DIN-rail clip onto the switch.
1. Use the screws to install the DIN-rail clip on the SI-IES-1x1D-LRT.
2. To remove the DIN-rail, uninstall by removing the screws.
Follow the steps below to hang the Hardened PoE injector on the DIN-rail track.
1. Insert the top of DIN-rail clip over the top edge of the DIN-rail track.
2. Lightly push down on the SI-IES-1x1D-LRT until the bottom of DIN-rail clip snaps onto the
bottom edge of the DIN-rail track.
3. Check that the SI-IES-1x1D-LRT is securely mounted on the track.
4. To remove the SI-IES-1x1D-LRT from the track, reverse the steps above.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 16 of 25
Wall Mounting (Optional)
Follow the steps below to mount the SI-IES-1x1D-LRT with the wall mount brackets.
1. Remove the DIN-rail clip from the SI-IES-1x1D-LRT by removing the three mounting screws as
shown below.
2. Place the wall mount brackets on the rear panel of the PoE Injector/Converter.
3. Use the existing screws to install the wall mount plates on the PoE Injector/Converter.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 18 of 25
4 Troubleshooting
□Select the proper UTP cable to construct your network. Use unshielded twisted-pair (UTP) or
shielded twisted-pair (STP) cable for RJ45 connections: 100Ω Category 3, 4 or 5 cable for
10Mbps connections, 100Ω Category 5 cable for 100Mbps, or 100Ω Category 5e/above
cable for 1000Mbps connections. Also be sure that the length of any twisted-pair connection
does not exceed 100 meters (328 feet).
□Diagnosing LED Indicators:To help identify problems, monitor the SI-IES-1x1D-LRT front
panel LED indicators that provide the device’s current status. These LEDs can help diagnose
common problems you may encounter during installation.
□Verify that you are using the right power cord and power adapter.
□If the SI-IES-1x1D-LRT is not producing full PoE+ output, ensure the power supply is
adjusted to provide the required input power. The converters accept 48~57VDC; higher
voltage (53~57VDC) required for some high powered PD loads. See Wiring the Power Inputs
on page 13.
□If the power LED does not light when the power cord is plugged in, you may have a problem
with the power cord or power source. Check for loose power connections, power losses and
power at the power outlet. If you still cannot resolve the problem, contact Lantronix technical
support for assistance.
□If the Injector/Converter LEDs are normal, the connected cables are correct, and the device
fails to transmit data, check your system’s Ethernet devices’ configuration or status.
□Check the DIP switch setting. The devices ship defaulted to 1000Base-T on the DIP switch.
When changing the speed from 1000Base-T to 100Base-T, the unit must be power cycled
after installing the 100Base-T SFP and setting the DIP switch to 100 Mbps. Then it will link at
100Base-T. See DIP Switch on page 8.

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 19 of 25
Specifications
SI-IES-1x1D-LRT technical specifications are listed below. Note that specifications are subject to
change without further notification.
Standards
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab, IEEE 802.3at,
IEEE 802.3z, IEEE 802.3af
Compliant with 802.3at in Environment A when using an isolated power supply
Max Frame Size 10K byte jumbo frames
Connectors
1 x SFP slot
1 x RJ45 (SI-IES-111D-LRT)
2 x RJ45 (SI-IES-121D-LRT)
2-pin removable terminal block
Status LEDs
Copper port: Link/ACT
Copper port: Gigabit transmission
SFP (Fiber) port: Link/ACT
PoE1: Power
PoE2: Power (SI-IES-121D-LRT)
PWR: Input power
Dimensions
Width: 1.44” [36.7 mm]
Depth: 3.72” [94.5 mm]
Height: 4.26” [108.4 mm]
Power Consumption
3.53 Watts (No PoE)
32.725 Watts (1 port PoE)
63.5 Watts (2 ports PoE)
Power Input 48-57VDC
Higher Voltage (50-53VDC) may be required for some high powered PD loads
Ingress Protection IP31
Environment
Operating: -40°C to +75°C
Storage: -40°C to +85°C
Humidity: 10% to 95% (non-condensing)
Altitude: 0 – 10,000 ft.
Weight 1.3 lbs. [0.59 kg]
Mounting DIN-rail, Wall-mount

Lantronix SI-IES-1x1D-LRT User Guide
33585 Rev. L https://www.lantronix.com/ Page 20 of 25
Certifications
Safety: UL508
Class 1, Division 2, Groups A,B,C and D Hazardous Locations
CE, FCC Class A
EN55011
EN55022/EN61000-6-4 (EMC)
EN55024/EN61000-6-2 (Immunity)
IEC/EN61000-4-2 (ESD)
IEC/EN61000-4-3 (RS)
IEC/EN61000-4-4 (EFT)
IEC/EN61000-4-5 (Surge)
IEC/EN61000-4-6 (CS)
IEC/EN61000-4-8 (Magnetic Field)
IEC60068-2-27 (Shock)
IEC60068-2-32 (Free Fall)
IEC60068-2-6 (Vibration)
MTBF
SI-IES-111D-LRT:
743,594 Hours Bellcore Ground Benign, Controlled; Temp 30°C.
653,092 Hours Bellcore Ground Fixed, Uncontrolled; Temp 30°C.
SI-IES-121D-LRT:
717,339 Hours Bellcore Ground Benign, Controlled; Temp 30°C.
613,639 Hours Bellcore Ground Fixed, Uncontrolled; Temp 30°C.
This manual suits for next models
1
Table of contents
Other Lantronix Media Converter manuals

Lantronix
Lantronix 6310 Series User manual

Lantronix
Lantronix C3210-10 Series User manual

Lantronix
Lantronix ION C3110 User manual

Lantronix
Lantronix SGFEB Series User manual

Lantronix
Lantronix 4110 Series User manual

Lantronix
Lantronix ION C2210 User manual

Lantronix
Lantronix C3100 Series User manual

Lantronix
Lantronix SISTG10xx-211-LRT-B Series User manual

Lantronix
Lantronix M/GE-ISW 01 Series User manual

Lantronix
Lantronix S3100 Series User manual