WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, use only with the appropriate Lutron 277V Hi-lume® or Eco-10™ (EcoSeries)
electronic ballasts for controlling the specific fluorescent lamps.
• Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 4 matching remotes with LEDs. The remote(s) will turn the light on at the brightness level
selected at the dimmer.
• Only use lamps listed on ballast label. Compact Fluorescent lamps must have four pins for dimming.
WARNINGS AND CAUTIONS:
• Lamps must be burned in at full intensity for 100 hours prior to dimming for proper dimming performance.
• For new installations, wire a test switch before installing dimmer.
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
The maximum current rating is 6A, which can be measured from
the incoming Hot (Black) on the dimmer. Refer to the ballast label
to determine the total load on the dimmer circuit. The total load is
calculated by adding all of the ballast input currents for all ballasts
on dimmer.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
Step 1
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure
that the ends of the wires from the wall box are straight
(cut if necessary). Remove insulation from each wire in
the wall box as shown.
Step 2
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE NUT / # OF COND.
COMBINATION CHART
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
Tools needed to install your Dimmer
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No.
VZH
Ø
6
Single
6A
Two Devices
6A
More than
2 Devices
6A
Changing the color of your Dimmer:
Your Dimmer will include three color options. The Dimmer ships
with the White frame attached. To change color of frame, proceed
as follows:
Push in side
at tab to release
Line up tabs and
press in side to attach
CAUTION:
Before installing your dimmer, check new installation wiring for any
shorts in the circuit.
• Turn OFF Power at circuit breaker or fuse.
• Using a standard switch, connect appropriate wires to Hot circuit
and ballast (refer to diagram).
• Turn ON Power. If lights do not turn ON, there is an open in the
circuit.
• If required, Turn OFF Power and correct wiring. Verify circuit
again. Warranty of dimmer will be voided if dimmer is turned ON
in a shorted circuit.
Connect wires per WIRING DIAGRAM as follows: Twist strands of
each lead tightly together and, with circuit conductors, push firmly
into appropriate wire connector. Screw connectors on clockwise
making sure no bare conductors show below the wire connectors.
Secure each connector with electrical tape. For all multi-location
applications, the dimmer must be installed in a wall box that has a
Load connection. The remote must be installed in a wall box with a
Line Hot connection and a Neutral connection.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
1) For Single-Pole Application, go to Step 3a.
2) For 3-Way Matching Remote (with LEDs) Application, go to
Step 3b.
3) For 4-Way Matching Remote (with LEDs) Application, go to
Step 3c.
Hot
Neutral
Black
White
Ballast
Switch
Orange
Line
277VAC, 60Hz
Step 3 Wiring your Dimmer:
Step 2 cont'd ASingle-Pole Wiring Application:
Black
Insulating label:
This wire is used in 3-way installations only.
For single pole installations do not remove
this insulating label.
White
Green
Orange
Red
Yellow/
Red
Dimmer
Insulating
Label
Black
Black
LOAD
Orange
Orange
Hot (Black)
Line
277VAC
60Hz
Neutral (White)
Red
Yellow/
Red
White
White
Green
Ground
277V Hi-Lume®
or
ECO-10TM
(EcoSeries)
Ballast
DimmerMatching Remote (w/LEDs)
Black
LOAD
Orange
Orange
Hot (Black)
277V Hi-Lume®
or
ECO-10TM
(EcoSeries)
Ballast
Line
277VAC
60Hz
Neutral (White)
Red
Yellow/
Red
White
WH BK
YL/RD
Black
White
Green
Ground
Green
Ground
Single Pole (One location) or 3-Way (Multi-location)
Fluorescent Dimmer
Cat. No. VZH
Ø
6-7L (Lighted)
6A-277VAC, 60Hz
INSTALLATION INSTRUCTIONS
Matching Remote Matching Remote Dimmer
Black
Black
White
White
Orange
Green
Green
Red
Yellow/Red
Yellow/Red
Black
White
Green
Yellow/Red
4-Way Wiring with Matching
Remote (w/LEDs) Application:
C
3-Way with Matching Remote
(w/LEDs) Wiring Application:
B
Matching Remote Dimmer
Black
Black
White
White
Orange
Green
Green
Red
Yellow/Red
Yellow/Red
DI-000-VZH06-02C
If installing Dimmer in a single device application, proceed with
the INSTALLING YOUR DIMMER section. If installing Dimmer in
a multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the side sections of the mounting
strap may require removal. Use pliers to carefully bend side
sections back and forth until they break off.
Installing Dimmer by itself or with other devices
Typically, removal of the side sections in multi-dimmer
installations requires a reduction of the dimmer’s capacity.
However, there is no reduction necessary for this device.
Refer to the chart for maximum load per dimmer.
Remove
all inner
side
sections
Do not
remove
outer
side
sections
Bend back and
forth to remove
side section
Air-Gap Switch: On the dimmer only, engage
the air-gap switch by gently pulling the bottom
of the push pad until it lifts mcompletely
out of the frame and a click is heard and all
LED’s are OFF (refer to Figure). This will cut
power to the fixture to replace the bulb. After
servicing is complete, push the push pad back
for normal operation.
Cleaning: Clean with a damp cloth. DO NOT
use chemical cleaners.
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning fullOFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights will
turn on to regardless of the previous light level at which they were
turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that
the lights will have to turn ON or OFF. Fade rates can be set to one
of 7 different settings.
This equipment has been tested and found to comply with the
limits for a Class B Digital Device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment
OFF and ON, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and
the receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician
for help.
ADVANCED PROGRAMMING FEATURES
To Program:
NOTE: Have a flashlight handy if this
dimmer controls the only light source
in the room.
1. On the dimmer only, engage the
air-gap switch by gently pulling the
bottom of the push pad until it lifts
completely out of the frame and
a click is heard and all LED’s are
OFF.
2. Press push pad back into frame
and hold push pad for 7 seconds
until the locator light and the top
LED (LED 1) starts blinking.
3. Upon releasing the push pad, the locator light will continue to
blink once per second indicating the dimmer is in Mode 1, Set
Minimum Brightness mode. To change the current Minimum
Brightness level from 1-50%, use the DIM/BRIGHT Bar. This
setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level
mode. The locator light will blink twice per second. To change the
current Set Dim-Lock level from 1-100%, use the DIM/BRIGHT
Bar. If this feature is not desired, press and hold the lower half
of the DIM/BRIGHT Bar until no LED is lit. This setting will
automatically be saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode.
The locator light will blink 3 times per second. To change the
current Fade Rate, use the DIM/BRIGHT Bar to move the LED to
the desired preset level. This setting will automatically be saved
by tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each
LED represents a preset level with LED 1 (Preset 1) located at the
top and LED 7 (Preset 7) located at the bottom. Refer to chart for
settings and defaults.
NOTE: The dimmer will exit program mode after 3 minutes of
inactivity.
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors of dimmer or
remote.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
• Intermittent dimmer operation
- Minimum load is under 40W.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
• Lights cycle ON and OFF
- Remove excess load.
* default
** LED #1 is on the top
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word "TOP" is facing
up on device strap.
• Partially screw in mounting screws in
wall box mounting holes
Gently lift bottom of
push pad out
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way application, the lights will turn
ON at brightness set on dimmer's DIM/BRIGHT bar. The lighting can
be controlled from either the dimmer or the remote location.
Covered by one or more US & Foreign
Patents and patents pending
Copyright©2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
Eco-10™ (EcoSeries) is a trademark and Hi-lume®is
a registered trademark of Lutron Electronics Inc.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton's
website at www.leviton.com
OPERATION
4-Way Wiring with Matching
Remote (w/LEDs) Application:
C
Testing your Dimmer prior to mounting
in wall box:
Step 4
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
Step 6
TROUBLESHOOTING
FCC COMPLIANCE STATEMENT
Preset
1*
2
4
5
6
7
3 3
7
6
5
4
2
1
LED**
No Fade
Approx. 1.5s from full off
Approx. 1.5s from full off
Approx. 0.5s from full off
Approx. 0.5s from full off
No Fade
Approx. 1.5s from full off
Fade On
Approx. 3s from full on
Approx. 10s from full on
Approx. 5s from full on
Approx. 1.5s from full on
Approx. 3s from full on
No Fade
Approx. 3s from full on
Fade Off
Fade Rate Presets
Advanced Features Summary
Mode
1
2
3
Description
Set Dim-Lock Level
Set Min. Brightness
Select Fade Rate
Range
0 -100%, 0=no lock
1 - 50%
1, 2, 3, 4, 5, 6 or 7
Default
0
25%
Preset #1
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof
of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: QualityAssurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened,abused,oralteredinanymanner,or is not used under normal operating conditions or not in accordance with any labels or instructions.
Therearenootherorimpliedwarrantiesofanykind,includingmerchantabilityandfitnessforaparticularpurpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty, including merchantability and fitness
foraparticularpurpose,islimitedtofiveyears.
Levitonisnotliableforincidental,indirect,special,orconsequential damages, including without limitation, damage to, or loss of use of, any equipment, lostsalesorprofitsordelayorfailuretoperformthis warranty obligation. The remedies provided herein are the exclusiveremediesunderthiswarranty, whether based on contract, tort or otherwise.
1
2
3
4
5
6
7
LED
Brightness
Display
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full
bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar
– Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar –
Lights dim to desired level. If you continue
to hold, the lights will DIM to minimum
level and then turn OFF.
NOTE: When lights are OFF you can
change the light level that the lights will
turn ON to using the DIM/BRIGHT Bar. If
there is a power outage, when the power
is restored the lights will return to the last
setting before the power interruption.
Push
Pad
Locator
Light
LED
Brightness
Display
DIM/
BRIGHT
Bar
• Restore power at circuit breaker or
fuse.
• Press pad until locator light is OFF.
Lights should turn ON. If lights do not
turn ON, press the upper half of DIM/
BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Dimmer
Black
LOAD
Orange
Orange 277V Hi-Lume®
or
ECO-10TM
(EcoSeries)
Ballast
Red
Yellow/
Red
White
WH BK
YL/RD
Black
White
Matching Remote
(w/LEDs)
Matching Remote
(w/LEDs)
Hot (Black)
Line
277VAC
60Hz
Neutral (White)
WH BK
YL/
RD
Green
Ground
Green
Ground
Green
Ground
Installation may now be completed
by tightening mounting screws into
wall box. Attach wallplate.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 5
DI-000-VZH06-02C

Other Leviton Dimmer manuals

Leviton VZX10-1L User manual

Leviton

Leviton VZX10-1L User manual

Leviton DDS6000 User manual

Leviton

Leviton DDS6000 User manual

Leviton RZP15 User manual

Leviton

Leviton RZP15 User manual

Leviton Topaz 96 User manual

Leviton

Leviton Topaz 96 User manual

Leviton RZCZ1 User manual

Leviton

Leviton RZCZ1 User manual

Leviton Decora Illumatech IPX06-1 User manual

Leviton

Leviton Decora Illumatech IPX06-1 User manual

Leviton LumaCan DRDDP User manual

Leviton

Leviton LumaCan DRDDP User manual

Leviton Vizia RF RZI06-1L User manual

Leviton

Leviton Vizia RF RZI06-1L User manual

Leviton Decora Smart DWVAA User manual

Leviton

Leviton Decora Smart DWVAA User manual

Leviton VZH08-1L User manual

Leviton

Leviton VZH08-1L User manual

Leviton Acenti ACH08 User manual

Leviton

Leviton Acenti ACH08 User manual

Leviton DDS3600R Operating instructions

Leviton

Leviton DDS3600R Operating instructions

Leviton Decora Mural MDI06-1 User manual

Leviton

Leviton Decora Mural MDI06-1 User manual

Leviton VZI06-1L User manual

Leviton

Leviton VZI06-1L User manual

Leviton DMX-512 Installation guide

Leviton

Leviton DMX-512 Installation guide

Leviton VZE04-1L User manual

Leviton

Leviton VZE04-1L User manual

Leviton Decora Illumatech IPM06-1L User manual

Leviton

Leviton Decora Illumatech IPM06-1L User manual

Leviton Vizia RZI6-1L User manual

Leviton

Leviton Vizia RZI6-1L User manual

Leviton QuickPort User manual

Leviton

Leviton QuickPort User manual

Leviton 6613-PL User manual

Leviton

Leviton 6613-PL User manual

Leviton Vizia RF RZP03-1LW User manual

Leviton

Leviton Vizia RF RZP03-1LW User manual

Leviton lumina 0-10VDC User manual

Leviton

Leviton lumina 0-10VDC User manual

Leviton Topaz 12 User manual

Leviton

Leviton Topaz 12 User manual

Leviton Decora Smart DN6HD User manual

Leviton

Leviton Decora Smart DN6HD User manual

Popular Dimmer manuals by other brands

Lex Products FD3-6KW user manual

Lex Products

Lex Products FD3-6KW user manual

Marmitek LW11G user manual

Marmitek

Marmitek LW11G user manual

LEGRAND HPM 700TM instruction manual

LEGRAND

LEGRAND HPM 700TM instruction manual

Crestron 6 Channel Dimmer Module CNLDM-6 Specification sheet

Crestron

Crestron 6 Channel Dimmer Module CNLDM-6 Specification sheet

Aladdin M3 user manual

Aladdin

Aladdin M3 user manual

Lightronics AS42L owner's manual

Lightronics

Lightronics AS42L owner's manual

movie-intercom RC4 quick start guide

movie-intercom

movie-intercom RC4 quick start guide

KNX CHROMOFLEX Pro instruction manual

KNX

KNX CHROMOFLEX Pro instruction manual

Sygonix 2464453 operating instructions

Sygonix

Sygonix 2464453 operating instructions

Crestron infiNET CLW-DIMS1RF manual

Crestron

Crestron infiNET CLW-DIMS1RF manual

Elko iNELS RFDEL-71B-SL manual

Elko

Elko iNELS RFDEL-71B-SL manual

SIMON URMET NEA 14550/2 manual

SIMON URMET

SIMON URMET NEA 14550/2 manual

Show Tec DimMaster Product guide

Show Tec

Show Tec DimMaster Product guide

WorkPro DUO DIM user manual

WorkPro

WorkPro DUO DIM user manual

WorkPro WD 616D KMT user manual

WorkPro

WorkPro WD 616D KMT user manual

PROLED L515092G user manual

PROLED

PROLED L515092G user manual

Clas Ohlson EFP700DC+EFV001 Guide

Clas Ohlson

Clas Ohlson EFP700DC+EFV001 Guide

EcoDim ECO-DIM.13 Zigbee manual

EcoDim

EcoDim ECO-DIM.13 Zigbee manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.