LG RESU10H Prime User manual

Installation Manual for RESU10H Prime
LG Energy Solution strongly advises users to exercise due care in following LG Energy
Solution’s product installation manual. Warranty claims are invalid if damage is caused by
human error in a manner inconsistent with the installation manual’s instructions.
Version 2.1
Scan QR code to view
[Installation Video Guide]
Scan QR code to view
[Installation Manual PDF File]
Scan QR code to download
[RESU Monitor (iOS)]
Scan QR code to download
[RESU Monitor (Android)]

ENGLISH
2
The information included in this manual is accurate at the time of publication.
However, this manual is subject to change without prior notice. In addition, the illustrations
LQWKLVPDQXDODUHPHDQWRQO\WRKHOSH[SODLQV\VWHPFRQ¿JXUDWLRQFRQFHSWVDQGLQVWDOODWLRQ
instructions.
Please note the images shown are for illustration purposes only.
Contents
1 Safety
1.1 Symbols
1.2 Safety Instructions
1.2.1 General Safety Precautions
1.2.2 Battery Handling Guide
1.2.3 Response to Emergency Situations
1.3 Warning Label
4XDOL¿HG3HUVRQQHO
2 Product Introduction
2.1 Technical Data
2.1.1 Dimensions and Weight
2.1.2 Performance
2.2 Features
2.3 Maintenance
3DFNDJLQJ6SHFL¿FDWLRQV
3 Installation
3.1 Mechanical Requirements
3.1.1 Package Contents
3.1.2 Basic lifting guide
3.1.3 Unboxing the Package
3.1.4 Installation Location
3.1.5 Clearance
3.1.6 Tools & Safety Gear Required
3.1.7 Appearance and Dimensions
3.1.8 System Clearance
3.1.9 Installing the Battery Pack
3.2 Installation process for Remote Monitoring Device (RMD)
3.2.1 Prepare for installation using RMD
3.2.2 Installation via RMD
3.3 Cable Connections
&DEOH&RQ¿JXUDWLRQ
3.3.2 Guide for cable connection and setting the DIP switch
3.3.3 Spring Terminal Blocks
4 Commissioning
4.1 LED Indicators
4.2 Powering On the Battery Pack
6KXWWLQJ2൵WKH%DWWHU\3DFN
5 Troubleshooting
5.1 Troubleshooting Overview
5.1.1 Post-Installation Checklist
5.1.2 Troubleshooting Guidelines
6 Uninstallation & Return
6.1 Return/Replacement Instructions
6.1.1 Uninstallation
6.1.2 Contact Information
7. Appendix
7.1 Connection in RESU10H Prime parallel battery system
7.1.1 Setting for communication termination resistor (About Section B)
7.1.2 Power cable (When using a combiner box)
7.2 RMD Applications
7.2.1 Battery Status check via RMD
7.2.2 BMS, DC/DC and RMD Update via RMD
7.2.3 Installation via RMD for web user

3
1 Safety
1.1 Symbols
Caution, risk of electric shock
'RQRWSODFHRULQVWDOOQHDUÀDPPDEOHRUH[SORVLYHPDWHULDOV
Install the product out of reach of children
Read the instruction manual, in its entirety, before starting installation
and operation
Heavy weight may cause serious back injuries
Do not dispose of the product with household waste
Recyclable
Disconnect the equipment before carrying out maintenance or repair
Observe precautions for handling electrostatic-sensitive devices
Protective Class 1
Caution, risk of electric shock, energy storage timed discharge.
1.2 Safety Instructions
For safety reasons, installers are responsible for familiarizing themselves with the contents of
this document and all warnings before performing installation and servicing.
1.2.1 General Safety Precautions
Over-voltages or wrong wiring can damage the battery pack and cause combustion which can
be extremely dangerous.
$Q\W\SHRISURGXFWEUHDNGRZQPD\OHDGWRDOHDNDJHRIHOHFWURO\WHVRUÀDPPDEOHJDV
$YRLGLQVWDOOLQJWKHEDWWHU\SDFNZKHUHÀDPPDEOHPDWHULDOVDUHVWRUHG'RQRWLQVWDOOLQSODFHV
where explosive gas or chemicals are present.
During installation of the battery, the utility grid and solar input must be disconnected from the
%DWWHU\3DFNZLULQJ:LULQJPXVWEHFDUULHGRXWE\TXDOL¿HGSHUVRQQHO
%DWWHU\SDFNVKRXOGRQO\EHVHUYLFHGE\TXDOL¿HGSHUVRQQHO
The electronics inside the battery pack are vulnerable to electrostatic discharge.
Be sure to be grounded before handling the battery pack.
Read the label with Warning Symbols and Precautions, which are visible under the Battery
Cover (see Section 1.3 Warning Label).
1.2.2 Battery Handling Guide
'RQRWH[SRVHWKHEDWWHU\WRDQRSHQÀDPH
'RQRWSODFHWKHSURGXFWQHDUÀDPPDEOHPDWHULDOVVXFKDVDQ\OLTXLG¿OOHG
petroleum containers, compressed natural gas/ propane/ welding fuel tanks, natural
gas supply lines, oxygen tanks, swimming pool chemicals, home furnaces, or
boilers, gas cans/kerosene cans, kerosene/oil powered portable heaters, oil rags,
fuel oil tanks, or garbage bins.
Do not expose or place the product near water sources.
Do not store or install the product in direct sunlight.
Install the product in an area with enough ventilation around the product.
Do not install the product in living area of dwelling units or in sleeping areas.
Store in a cool and dry place. (Do not store in greenhouses or storage areas for
KD\VWUDZFKD൵DQLPDOIHHGIHUWLOL]HUYHJHWDEOHVRUIUXLWSURGXFWV
6WRUHWKHSURGXFWRQDÀDWOHYHOVXUIDFH
Store the product out of reach of children and animals.
Store the product in clean environment, free of dust, dirt and debris.
'RQRWGLVFRQQHFWGLVDVVHPEOHRUUHSDLUWKHSURGXFWE\XQTXDOL¿HGSHUVRQQHO
2QO\TXDOL¿HGSHUVRQDODUHDXWKRUL]HGWRKDQGOHLQVWDOODQGVHUYLFHWKHSURGXFW
Do not damage the product by dropping, deforming, impacting, cutting or
SHQHWUDWLQJZLWKDVKDUSREMHFW'RLQJVRPD\FDXVHD¿UHRUOHDNDJHRI
electrolytes.
Do not touch the product if liquid spills on it. There is a risk of electric shock.
7KHEDWWHU\UHTXLUHVDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQFDEOLQJDLUÀRZVDIHW\DV
detailed in 3.1.8 system clearance
(For wall-mounted option, keep lower clearance area free from foreign materials)
The outer cable connection hole should be sealed to prevent ingress of foreign
objects.
Do not step on the packaging or the product may be damaged.
'RQRWSODFHDQ\IRUHLJQREMHFWVRQWRSRIWKH%DWWHU\3DFNDQGRQWKHFRROLQJ¿Q
Do not put the battery pack upside down on the ground.
Do not connect the power cables at the terminal block in the opposite direction.
Do not charge or discharge a damaged battery.
If the product is installed in a garage or carport, ensure there is adequate clearance
from vehicles.
7KHEDWWHU\SDFNKDVEHHQFHUWL¿HG,3DQGFDQEHLQVWDOOHGLQGRRUVDVZHOO
as outdoors. However, if installed outdoors, do not allow the battery pack to be
exposed to direct sunlight or water sources, as they may cause:
- Power limitation phenomena in the battery (with a resulting decrease in energy
production by the system).
- Premature wear of the electrical/electromechanical and mechanical components.
- Reduction in performance, performance warranty and possible damage of the battery
Only use the product with a authorized inverter by LG Energy Solution.
For a list of compatible inverters, visit the LG ESS Battery Website by the URL
below and check the ‘Home Battery’ > ‘Product Info’ menu.
https://www.lgessbattery.com/us (in case of North America)
https://www.lgessbattery.com/au (in case of Australia)
https://www.lgessbattery.com/eu (in case of all EU-countries in general)
https://www.lgessbattery.com/de (in case of Germany)
https://www.lgessbattery.com/it (in case of Italy)
https://www.lgessbattery.com/es (in case of Spain)
Do not connect any AC conductors or photovoltaic conductors directly to the
battery pack. The battery pack is only to be connected to the inverter.
The product should be installed in accordance all applicable local standards and
regulations
Follow local ordinance when installing in a garage for vehicle clearance [min.
3ft(915mm)]
1.2.3 Response to Emergency Situations
The Product includes internal fault mechanisms designed to prevent failures and subsequent
risk hazards. However, LG Energy Solution cannot guarantee safety performance if the Product
was ever exposed to abuse, damage or negligence, before or after it was put into operational
use.
If a user happens to be exposed to the internal materials of the battery cell, the
following actions are recommended.
In case of inhalation: Leave the contaminated area immediately and seek medical
attention.
In case of contact with eyes: Rinse eyes with running water for 15 minutes and
seek medical attention.
In case of contact with skin: Wash the contacted area thoroughly with soap and
seek medical attention.
In case of ingestion: Induce vomiting and seek medical attention.
,ID¿UHEUHDNVRXWDWWKHORFDWLRQZKHUHWKHEDWWHU\SDFNLVLQVWDOOHGSHUIRUPWKHIROORZLQJ
countermeasures.
8WLOL]H¿UHH[WLQJXLVKLQJPHGLD
A respirator is not required during normal operation.
8VHDQ)0RU&2H[WLQJXLVKHUIRUEDWWHU\¿UHV
8VHDQ$%&¿UHH[WLQJXLVKHULIWKH¿UHLVQRWIURPWKHEDWWHU\DQGKDVQRW\HWVSUHDGWRLW
)ROORZSURSHU¿UH¿JKWLQJLQVWUXFWLRQV
1. ,ID¿UHRFFXUVZKHQFKDUJLQJEDWWHULHVSURYLGHGLWLVVDIHWRGRVRGLVFRQQHFW
WKHEDWWHU\SDFNFLUFXLWEUHDNHUWRVKXWR൵WKHSRZHUFKDUJH
2. ,IWKHEDWWHU\SDFNLVQRWRQ¿UH\HWH[WLQJXLVKWKH¿UHEHIRUHWKHEDWWHU\SDFN
FDWFKHV¿UHSUHIHUDEO\ZLWKZDWHU
3. ,IWKHEDWWHU\SDFNLVRQ¿UHGRQRWWU\WRH[WLQJXLVKLWDQGHYDFXDWHSHRSOH
from the premises immediately.
WARNING
There may be a possible explosion when batteries are heated above 150°C. When a
battery pack is burning, it will leak poisonous gases. Do not approach it.
(൵HFWLYHZD\VWRGHDOZLWKDFFLGHQWV
2QODQG3ODFHWKHGDPDJHGEDWWHU\LQWRDVHJUHJDWHGSODFHDQGFDOO\RXUORFDO¿UH
department or service engineer.
In water: Stay out of the water and do not touch anything if any part of the battery, inverter,
or wiring is submerged.
Do not use the submerged battery again. Contact your service engineer for assistance.

ENGLISH
4
1.3 Warning Label
Product/warning label and Battery Control Unit’s traceability label are behind the front cover.
The front cover opens by turning the front cover handle counterclockwise. Battery Modules’
traceability labels are attached to the side of the Battery Modules.
1
2-1
2-2
2-2
Placethespacer
Intheline HERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Handle
Turn counterclockwise
1. Product/Warning Label
*$1<14>&
RESU10H Prime
Rechargeable
Li-ion
111kg(244.7lb)
: 420V / 410V
: 9.6 kWh
: 1.106kA / 0.97ms
EH153064P8S8
· Ne pas démonter ou réparer pour afin d’éviter des blessures, chocs électriques ou
brûlures. Seul un personnel de dépannage qualifié est autorisé à intervenir sur
l’appareil.
· Ne pas charger et décharger arbitrairement. Cela risquerait d’engendrer des défauts,
chocs électrique ou brulures.
· Ne pas endommager l’appareil par des chutes, déformations, impacts, coupures
ou par des objects pointus. Cela pourrait engendrer une fuite du liquid électrolytique.
· Measurer les tensions en continu avant câblage.
· ATTENTION : le system de la batterie est une source de tension bidirectionnelle.
· Do not disassemble or repair to avoid injuries, electric shock or burns.
Service by authorized personnel only.
· Do not charge or discharge arbitrarily. It may lead to fault, electric shock or burns.
· Do not damage the unit in such ways as drop, deform, impact, cut or spear with a
sharp object. It may cause electrolyte leakage.
· Measure DC voltages before working in wiring box.
· WARNING: Battery system is a bidirectional source of voltage.
Battery circuit breaker, and inverter must both be off, before working in the wiring box.
· Do not attempt to break open the unit. The units are only serviceable by certified
personnel.
· Do not place near open flame or incinerate. Keep out of reach of children or animals.
· Do not install this product in the place exposed to the direct sunlight.
· Sometimes even if the DC Disconnect is OFF, there may be voltage on the
lines to the Inverter. So please ensure the DC Disconnect on the Inverter is also
OFF during service/ maintenance.
· Single person lift could cause injury. Use assistance when moving or lifting.
· Electric shock hazard if a ground fault is indicated, normally grounded
conductors may be Ungrounded and energized.
· Verboten zu zerlegen oder zu reparieren, um Verletzungen wie Stromschlag oder
Brände zu vermeiden. Nur geschulte Fachkräfte dazu berechtigt.
· Verboten zu laden oder entladen. Es könnte zu Fehler, Stromschlag oder auch
Brandgefahr führen.
· Schäden am Gerät wie Herunterfallen, Deformierungen, äußere Einflüsse,
aufschneiden mit einem spitzen Gegenstand müssen verhindert werden. Es könnte
dazu führen, dass Elektrolyt ausläuft.
· Messen Sie zuerst die DC- Spannung bevor Sie am Gerät arbeiten wollen.
· WARNUNG: Das Batteriesystem ist eine bidirektionale Spannungsquelle.
Batterie-Freischalter und Wechselrichter müssen ausgeschalten sein bevor
Sie an beiden Geräten arbeiten wollen.
· Versuchen Sie nicht die Batterie aufzubrechen. Die Geräte sind nur durch
zertifiziertes Personal bedienbar.
· Platzieren Sie die Batterie nicht in der Nähe von offenem Feuer oder
Zündquellen.
· Halten Sie Kinder und Tiere fern.
· Installieren Sie die batterie nicht in Umgebungen wo sie direktem Sonnenlicht
ausgesetzt ist.
· Es kann vorkommen, dass selbst im ausgeschalteten Zustand des Speichers
eine Spannung zwischen Batterie und Wechselrichter messbar ist.
· Also stellen Sie immer sicher, dass der DC- Trenner des Wechselrichters ist auch
ausgeschaltet während Wartungen oder Service-Arbeiten durchgefülrt werden.
· Einzelne Personen können sich beim Anheben des Speichers verletzen. Holen Sie sich
Hillfe, wenn sie den Speicher versetzen oder anheben müssen.
· Es herrscht Stromschlaggefahr, wenn es zu einem Erdschluss kommen sollte. Es kann
vorkommen, dass geerdete Leiter doch nicht geerdet wurden und unter Strom stehen.
Le disjoncteur du circuit de batterie et l’onduleur doivnt être hors tension
avant câbalge.
· Ne pas placer prés d’une flamme ou incinéré le produit.
· Tenir hors de portée des enfants ou d’animaux.
· Ne pas installer le produit dans un endroit directement exposé au soleil.
· Parfois, même si le courant continu est coupé, il peut y avoir du courant dans
les lignes de l’onduleur. Assurer vous donc que l’onduleur est également hors
tension durant les interventions de maintenance.
· Porter l’appareil seul personne entraine un risque de blessure. Merci de
demander une assistance pour porter ou déplacer l’appareil.
· Si un défaut de la terre est indiqué alors il y a risque de choc électrique.
Dans ce cas il se peut que la mise à a la terre ne fonctionne pas.
2. Traceability label
2-1. Battery Control Unit 2-2. Battery Module
EH153064P8S8XXX
żżżżżżżżżż
SH077064P8S8XXX
żżżżżżżżżżA
SH077064P8S8XXX
żżżżżżżżżżB
4XDOL¿HG3HUVRQQHO
This guide for the tasks and procedures described herein is intended for use by a trained and
TXDOL¿HGHOHFWULFLDQRULQVWDOOHUZKRVDWLV¿HVDOORIWKHIROORZLQJUHTXLVLWHV
Knowledge of the safe, functional principles and operation of grid-tied and non-
grid tied energy systems
Knowledge of the dangers and risks associated with installing and using electrical
devices and acceptable mitigation methods
Knowledge of and adherence to this guide and all safety precautions
2EWDLQVDOOTXDOL¿FDWLRQVVSHFL¿HGLQSURGXFWZDUUDQW\¿OH7KLVLQFOXGHVEXWLV
not limited to:
5(68FHUWL¿FDWLRQUHOHYDQWWRWKHEDWWHU\PRGHO
: Knowledge of local electrical safety codes standards, i.e., NEC.
: Electrical licence for battery installation required by the country or state
Repairing the battery by disassembly is possible only at the LG Service Center or
by a person with maintenance authorization from LG Energy Solution
2 Product Introduction
2.1 Technical Data
2.1.1 Dimensions and Weight
RESU10H Prime
Part Number EH153064P8S8
Width 504 mm (19.8”)
Height 817 mm (32.2”)
Depth 295 mm (11.6”)
Weight 1)
Total 111 kg (244 lbs)
Module 82 kg (180 lbs)
Control
Unit 24 kg (53 lbs)
Connect
Plate 5 kg (11 lbs)
1) Battery pack weights may vary slightly.
2.1.2 Performance
Electrical Characteristics
Usable Energy 1) 9.6 kWh
Battery Capacity 64.1 Ah
Voltage Range 350 to 450 VDC
Absolute Max. Voltage 595 VDC
Max. Current (charging/discharging) 14.3A @ 350V
Max. Power (charging/discharging) 5 kW
Peak Power 2) (only discharging) 7 kW for 10 sec.
Peak Current (only discharging) 20.9 A for 10 sec.
Communication Interface RS485/ CAN
DC Disconnect Circuit Breaker
Connection Method Spring Type Connector
User Interface LEDs for Normal and Fault Operation
Operating Conditions
Installation Location Indoor/Outdoor
Operating Temperature charge 14°F to 122°F (-10°C to 50°C)
discharge -4°F to 122°F (-20°C to 50°C)
Operating Temperature
(Recommended)
59°F to 86°F (15°C to 30°C)
Storage Temperature -22°F to 140°F (-30°C to 60°C), acceptable for 7
days in total
-4°F to 113°F (-20°C to 45°C), acceptable for the
¿UVWPRQWKV
-4°F to 86°F (-20°C to 30°C), acceptable for months
7~12
Humidity 5% to 95%
Altitude Max. 6,562 ft (2,000 m)
Cooling Strategy Natural Convection
&HUWL¿FDWLRQ
Safety Cell
Battery
Pack
UL1642
CE / RCM / IEC 62619 / UL1973 /
IEC62477-1
Emissions FCC
+D]DUGRXV0DWHULDOV&ODVVL¿FDWLRQ Class 9
Transportation UN38.3
Ingress Rating IP55
ဵ7HVW&RQGLWLRQV7HPSHUDWXUH႔ႏDWWKHEHJLQQLQJRIOLIH
ဵ(QHUJ\LVPHDVXUHGXQGHUVSHFL¿FFRQGLWLRQVIURP/*(QHUJ\6ROXWLRQ&3&9&3
1) Value for battery pack only. Maximal usable energy at the AC output may vary by condition,
VXFKDVLQYHUWHUH൶FLHQF\FRQ¿JXUDWLRQDQGWHPSHUDWXUH
2) Peak current excludes repeated short duration (less than 10 sec. of current pattern).
817 mm
(32.2”)
295 mm
(11.6")
504 mm
(19.8")

5
1. Short Circuit Current/Duration
Short Circuit Current 1.106 kA
Duration 0.97 ms
2. Arc Flash Protection Calculations
,QRUGHUWRSURWHFWSHUVRQQHOIURPWKHSRVVLELOLW\RIJHWWLQJLQMXUHGE\DQDUFÀDVK
KD]DUGDUFÀDVKFDOFXODWLRQRIWKHEDWWHU\V\VWHPLVHVWLPDWHGZLWKWKH,QFLGHQW(QHUJ\
Calculations refer to Annex D of NFPA 70E.
Battery System Voltage 171.4V
Battery System Internal Resistance ȍ
Bolted Fault Current 1.106 kA
Arcing Current 0.553 kA
Clearing Time 792 us
Arc Flash Incident Energy 0.000088 Cal/cm
2
Working Distance 450 mm (18inches)
Battery system installers must wear PPE (Personal Protective Equipment) according to
NFPA 70E Article 130.
* NFPA(National Fire Protection Association)
WARNING
When installing the battery system, the worker shall wear arc-rated clothing
in every occasions and places to protect him/her from any possible exposure
WRDQHOHFWULFDUFÀDVK
The arc-rated clothing worn by the worker must assure the worker’s
movement and visibility while covering all ignitable clothing.
The worker shall always wear a non-conductive safety helmet to protect him/
her from any danger of head injury from electric shock or burns due to the
contact with energized electrical conductors or circuit parts resulting from
electrical explosion.
The worker shall wear non-conductive protective equipment for the face,
neck, and chin to protect him/her from danger of injury from exposure to
HOHFWULFDUFVRUÀDVKHVUHVXOWLQJIURPDQHOHFWULFDOH[SORVLRQ
The worker shall wear non-conductive protective equipment for the eyes
WRSURWHFWKLPKHUIURPDQ\GDQJHURILQMXU\IURPHOHFWULFDUFVRUÀDVKHV
resulting from an electrical explosion.
7KHZRUNHUVKDOOZHDUKHDULQJSURWHFWLRQZLWKLQWKHDUFÀDVKERXQGDU\
The worker shall wear heavy-duty leather gloves or arc-rated gloves,
VDWLVI\LQJWKHIROORZLQJUHJXODWLRQOHYHOIRUDUFÀDVKSURWHFWLRQ,QWKHFDVH
of wearing the rubber gloves for the shock protection, he/she shall wear
additional leather protectors above the gloves.
The worker shall wear heavy-duty leather footwear or dielectric footwear or
ERWKWRSURYLGHVRPHDUFÀDVKSURWHFWLRQ
The worker shall inspect arc-rated apparel before every use. Work clothing
RUDUFÀDVKVXLWVWKDWDUHFRQWDPLQDWHGRUGDPDJHGWRWKHH[WHQWLPSDLULQJ
the protective qualities, shall not be used. Protective items that become
FRQWDPLQDWHGZLWKJUHDVHRLOÀDPPDEOHOLTXLGVRUFRPEXVWLEOHPDWHULDOV
shall not be used.
The garment manufacturer’s instructions for care and maintenance of arc-
rated apparel shall be followed.
Arc-rated apparel shall be stored in a manner that prevents physical damage;
damage from moisture, dust, or other deteriorating agents; or contamination
IURPÀDPPDEOHRUFRPEXVWLEOHPDWHULDOV
2.2 Features
Compact energy storage unit for domestic photovoltaic system compatibility
Residential 400V DC battery pack system: Daily cycle and emergency back up
capability.
DC/DC Circuit
Breaker
(600V)
++
--
Circuit Breaker
Battery Inverter
Battery Power
Interface
Inverter Power
Interface
Protection devices included as follows:
- Inverter Power Interface for protection against overvoltage, overcurrent, external
short-circuit, reverse polarity, inrush current and over temp.
- Battery Power Interface for protection against internal short-circuit, overvoltage,
overcurrent, over temp and undervoltage.
Flexible installation: Indoors or Outdoors
2.3 Maintenance
RESU10H Prime does not require maintenance during normal operation if properly installed
per the installation manual. In the event of fault, contact the regional service center.
3DFNDJLQJ6SHFL¿FDWLRQV
Category Contents
Size (L×W×H) 720 mm
(28.3”)
845 mm
(33.3”)
910 mm
(35.8”) Outer Size
Qty/Box (ea) 1
Packaging
Materials
Box Corrugated Cardboard Disposable
Inner Corrugated Cardboard Disposable
Pallet Wood Disposable
Weight
Product 111 kg (244.7 lbs)
1 pack/box
(Battery Module (x2) + Battery
Control Unit + enclosed items)
Packaging 39 kg (86.0 lbs) Pallet (10.5kg) + Box (28.5kg)
Gross 150 kg (330.7 lbs) Product + Packaging
3 Installation
3.1 Mechanical Requirements
3.1.1 Package Contents
The following items are included in the package:
Battery Module A&B Battery Control Unit Module Connect
Plate
Module Support
BRKT (x2)
Standing Bracket
1 & 2
Spacer (x2) M6 x L10 Flange
Bolt (x18)
M5 × L200 Long
Flange Bolt (x6)
3/4"-1" Adapter (x2) Cap (x2) Manual Drill template
Cable ties (Optional)
Wall Mounting
Bracket
(Optional)
M8 x L15 Sems
Bolt (x8)
Table of contents
Languages:
Other LG Inverter manuals
Popular Inverter manuals by other brands

BARRON
BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer
Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil
electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar
Silicon Solar TPS555-1230 instruction manual

Mission Critical
Mission Critical Xantrex Freedom SW-RVC owner's guide

HP
HP 3312A Operating and service manual