HP90 Recessed Fluorescent H9S2GLR132 or 232
Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T8
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR232UNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor. See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To
reduce glare the average brightness at 65° shall not exceed 3317 candelas per square
meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less
than 76.0%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Specifications (continued)
Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white
polyester enamel. Rust preventative undercoating. Reflector – low iridescence specu-
lar aluminum 95% reflectance.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix
to catalog no., ie: (A)
HP90
Direct/Indirect
Recessed
S
Body Style:
S= Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
32
Lamp:
(By Others)
32 =T8 32W*
(Nominal 48")
* 28W T8 available
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1 Lamp
2=2 Lamp
Model No. H9S2GLR132UNVHI
LER = FP - 74.5 IW - 31.2 BF - 0.88
Comparative yearly lighting energy cost per
1000 lumens = $3.22
Report Number: G2010221
Catalog Number: H9S2GLR132UNVHI
Lamps: (1) F32 T8
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: QTP1X32T8
Report is based on 3100 Lumens per lamp.
Efficiency: 85.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.800 22.800
0.0 45.0 90.0 FLUX
0 770 770 770
5 765 768 771 73
15 736 753 769 213
25 680 720 755 332
35 601 665 723 416
45 499 590 669 454
55 381 497 596 442
65 257 392 514 387
75 136 280 328 266
85 38 47 35 60
90 000
CANDELA DISTRIBUTION0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1017. 1202. 1363.
55 957. 1248. 1497.
65 876. 1336. 1752.
75 757. 1559. 1826.
85 628. 777. 579.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 92 87 83 82 79 76 78 76 74
02 83 75 69 70 65 61 68 63 60
03 75 65 58 61 55 50 59 54 49
04 68 57 49 54 47 42 52 46 42
05 63 51 43 48 41 36 46 40 36
06 58 46 38 43 36 31 42 36 31
07 53 41 33 39 32 28 38 32 27
08 49 37 30 36 29 24 35 29 24
09 46 34 27 33 26 22 32 26 22
10 43 32 25 30 24 20 29 24 20
ZONE LUMENS % LAMP % FIXT
00-030 619 20.0 23.4
00-040 1034 33.6 39.2
00-060 1930 62.2 73.0
00-090 2642 85.2 100.0
90-180 000000.0 000.0
00-180 2642 85.2 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
H9 Standard HP90
HY For NYC Code – I.B.E.W. Manufactured
Ballast Type:
<10THD
1 or 2 Lamp Elec. T8 HI*
1 or 2 Lamp Elec. T8 P2†††
LOL Dimming T8 PS*
*Instant Start Standard
†Program Start
Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use
H
I
Ballast Code.
Model No. H9S2GLR232UNVHI
LER = FP - 77.9 IW - 59.7 BF - 0.88
Comparative yearly lighting energy cost per
1000 lumens = $3.08
Report Number: G2010039
Catalog Number: H9S2GLR232UNVHI
Lamps: (2) F32 T8
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: ICN-2P32-SC
Report is based on 3100 Lumens per lamp.
Efficiency: 85.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.800 22.800
0.0 45.0 90.0 FLUX
0 1595 1595 1595
5 1584 1588 1594 151
15 1525 1550 1576 439
25 1409 1473 1538 681
35 1204 1356 1465 849
45 1028 1198 1343 920
55 783 1000 1172 885
65 523 772 973 754
75 267 523 604 497
85 59 90 62 107
90 000
CANDELA DISTRIBUTION0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2095. 2441. 2736.
55 1967. 2512. 2944.
65 1783. 2632. 3317.
75 1486. 2911. 3362.
85 975. 1488. 1025.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 92 88 84 82 79 76 79 76 74
02 83 76 69 71 66 62 68 64 60
03 75 66 58 62 56 51 59 54 50
04 69 58 50 54 48 43 52 47 42
05 63 51 43 49 42 37 47 41 36
06 58 46 38 44 37 32 42 36 32
07 54 42 34 40 33 28 38 32 28
08 50 38 30 36 30 25 35 29 25
09 46 35 27 33 27 22 32 26 22
10 44 32 25 31 24 20 30 24 20
ZONE LUMENS % LAMP % FIXT
00-030 1271 20.5 24.0
00-040 2120 34.2 40.1
00-060 3925 63.3 74.3
00-090 5284 85.2 100.0
90-180 000000.0 000.0
00-180 5284 85.2 100.0
ZONAL LUMEN SUMMARY
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 12/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.