LUX LUMEN Jumbo User manual

Jumbo
RGBW Led bar
Order code: 10713

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.2/17
T: +32 3 293 35 50 –www.lux-lumen.com
CONTENTS
1PICTURE.....................................................................................3
1.1 GENERAL....................................................................................... 3
1.2 RANGE OF LENSES ............................................................................ 3
2DIMENSIONS ...............................................................................4
33 SAFETY INFORMATION.................................................................5
3.1SYMBOLS ...................................................................................... 5
3.2 PROTECTION FROM ELECTRIC SHOCK ....................................................... 6
3.3 PROTECTIONS FROM FIRE AND BURNS...................................................... 6
3.4 PROTECTION FROM INJURY .................................................................. 7
3.5 DISPOSING OF THIS JUMBO RGBW LED-BAR............................................. 7
4PHYSICAL INSTALLATION................................................................8
4.1 UNPACKING.................................................................................... 8
4.2 MOUNTING..................................................................................... 8
4.3 LOCATION AND ORIENTATION ............................................................... 8
5EXTERNAL CONNECTIONS...............................................................9
5.1 CURRENT POWER INPUT ...................................................................... 9
6EMC AND SAFETY REQUIREMENTS ..................................................11
7INSTALLATION SETUP ..................................................................12
7.1 SPECIFICATION.............................................................................. 12
8SERVICE AND MAINTENANCE .........................................................13
8.1 SAFETY PRECAUTIONS ...................................................................... 13
8.2 CLEANING.................................................................................... 13
9WARRANTY ...............................................................................14
9.1 APPLICATION OF WARRANTY............................................................... 14
9.2 RMA PROCEDURE........................................................................... 16
10 LIST OF USED ABBREVIATIONS .......................................................17

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.3/17
T: +32 3 293 35 50 –www.lux-lumen.com
1Picture
1.1 General
Jumbo
Detail Jumbo with asymmetric lenses
1.2 Range of lenses
15° 24° 31° 43°x16°
Spot Medium Wide Asymmetrical

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.4/17
T: +32 3 293 35 50 –www.lux-lumen.com
2Dimensions
The maximum height with bracket: 120 mm

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.5/17
T: +32 3 293 35 50 –www.lux-lumen.com
33Safety information
Before installing, powering up, or servicing the Jumbo RGBW led-bar, it is
highly recommended that you read this manual and ensure yourself that
you completely understand its content. Observe the safety precautions in
this manual. Install and operate the led-unit only as described in this
manual, and in conformity with local regulations. If you have any questions
how to operate this Jumbo RGBW led-bar safely, please contact your point
of sale.
3.1 Symbols
Following symbols are used to identify important safety information on the
Jumbo RGBW led-bar and in this manual.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.6/17
T: +32 3 293 35 50 –www.lux-lumen.com
3.2 Protection from electric shock
Although this device itself does not operate with dangerous voltages, the
installation in which it is intended to be used, can contain dangerous
voltages.
Shut down the power of the complete installation before carrying out any
installation, or maintenance work.
Use only AC to DC power sources, suitable for the application, and conform
to local regulations. Please ensure yourself that the AC to DC power supply
is able to deliver the rated current requirements of the installation.
If any cable, seal or housing is damaged, cracked, or reformed, disconnect
the power of the installation immediately.
For any additional servicing, not described in this manual, please contact
your point of sale.
3.3 Protections from fire and burns
Do not operate this led-unit if ambient temperature is over 45 °C (113°F).
Please ensure yourself that sufficient ventilation around the led-bar is
possible.
It might be necessary to allow the led-bar to cool down for 5 minutes,
before servicing.
Do not modify the led-fixture, in a way, not described in this manual.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.7/17
T: +32 3 293 35 50 –www.lux-lumen.com
3.4 Protection from injury
Ensure yourself that the led-bar and all its accessories are securely
fastened. Verify that the led-bar is firmly fixed to its supporting
underground.
3.5 Disposing of this Jumbo RGBW led-bar
This led-lighting device is manufactured in compliance with directive of the
European community: waste electrical and electronically equipment. Please
help to preserve our environment and ensure that this Jumbo RGBW Led-
bar will be recycled properly at the end of its life.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.8/17
T: +32 3 293 35 50 –www.lux-lumen.com
4Physical installation
Thank you for selecting this Jumbo RGBW led-bar as best solution in your
setup.
Warning! Read the safety precautions in this manual before integrating this
led-bar into your installation.
Installation must be carried out by qualified professionals only.
Assure yourself that there is sufficient and unrestricted air flow around the
Jumbo RGBW led-bar.
4.1 Unpacking
The following items are included in your package:
•LED fixture with focussing bracket included
•Protective antistatic packaging, with short form manual
4.2 Mounting
The Jumbo RGBW led-bar can be mounted on all kind of non-combustible
materials but take in consideration that the module can have a Tc of approx
30 °C higher as ambient temperature.
In case of problems, or doubts, please contact your point of sale.
4.3 Location and orientation
This led-bar can be used in all directions.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.9/17
T: +32 3 293 35 50 –www.lux-lumen.com
5External connections
5.1 Current power input
Safety precautions
Never connect the live power on the input terminals of the Jumbo RGBW
led-bar! In case of doubts, contact your point of sale.
Polarity
The Jumbo RGBW led-bar is polarity sensitive. So observe polarity and
cabling:
•Brown inner conductor = positive
•Yellow inner conductor = negative
•Green inner conductor = negative
•White inner conductor = negative
•Grey inner conductor = negative
Improper connection might damage the Jumbo RGBW led-bar and power
supply permanently. In case of inversed polarity, the warranty is void.
Power supply: Rated current
The rated input Current range of the Jumbo RGBW led-bar is 700 mA.
Please note, never apply a 12 V or 24 V DC to the units. This will damage the
units permanently.
Preferred IP67 dimmable driver:
➢Lux Lumen 12ch leddriver 700mA
•Max. Jumbo RGBW led-bars: 3 pcs
•Order code: 10129
Applying power
Make sure to connect the Jumbo RGBW led-bar first, before applying power,
otherwise the Jumbo RGBW led-bar can be damaged.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.10/17
T: +32 3 293 35 50 –www.lux-lumen.com
Cable
Cable type Omerin 5x0,25mm
Brown
+700mA
Yellow
Red
Green
Green
White
Blue
Grey
White
Please ensure yourself that the cable end is watertight sealed at the
connection. If this is not properly done, water can pass through the inner
conductors of the cable and damage the internal electronics of the Jumbo
RGBW led-bar.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.11/17
T: +32 3 293 35 50 –www.lux-lumen.com
6EMC and safety requirements
The Jumbo RGBW led-bar is fully compliant to the LVD and EMC directive of
the European council, if used in a properly designed setup.
The Jumbo RGBW led-bar is only intended to be used in lighting
applications, and as such, the complete assembly of led-unit and power
supply needs to be fully compliant with the harmonized standards:
LVD requirements of the power supply
•EN 60598: general requirements of lighting equipment.
EMC requirements of the power supply
Immunity according to:
•EN 61547:2009 (General EMC immunity requirements lighting eq.)
•EN 61000-4-1:2006 (General immunity testing techniques)
•EN 61000-4-2:2008 (ESD immunity test)
•EN 61000-4-3:2006 + A1:2007 (Radiated immunity test)
•EN 61000-4-4:2004 (Fast transients and burst immunity)
•EN 61000-4-5:2005 (Surge immunity test)
•EN 61000-4-6:2008 (Conducted immunity test)
•EN 61000-4-8:1993 (Magnetic field immunity test)
•EN 61000-4-11:2004 (Voltage variations immunity test)
•EN 61000-6-1:2005 (Generic standards for immunity)
Emission according to:
•EN 61000-3-2:2005+A1:2008+A2:2009 (Harmonics emission
test<16A)
•EN 61000-3-3:2008 (Flicker+ voltage changes limits< 16A)
•EN 55015:2006+A2:2009 (Conducted + radiated emission lighting
equipment)
To achieve this compliance, a proper power supply must be supplied. In
case of doubts, contact your point of sale.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.12/17
T: +32 3 293 35 50 –www.lux-lumen.com
7Installation setup
7.1 Specification
The Jumbo RGBW led-bar is a robust, compact and efficient solution for
lighting of wide surfaces or big objects.
The ingress protection of this Jumbo RGBW led-bar is IP67, and as such,
the unit can be used in outdoor as well as indoor applications.
The housing is made out of anodized aluminum in black finish.
The protective cover is made out of tempered glass.
The Jumbo RGBW led-bar itself is 600mm long with 36 LEDs, 16mm pitch
in between.
A range of lenses is available to choose from. The light beam can be
focused by rotating the bracket.
It uses a current controlled power supply, able to supply 700mA.
•Power consumption: +/-80W
•Power voltage: Do not apply voltage sources!
•Current: max. 700mA (full rated output)
•Weight: approx. 4kg
•Different lenses are possible:
oSpot: 15°
oMedium: 24°
oWide: 31°
oAsymmetrical: 43° x 16°
•LED color: RGB+W
Different white light led-colors are possible:
oWarm white: 2700K
oWarm white: 3000K
oNeutral white: 4000K
oCold white: 5700K
•Maximum operating temperature: -20°C to 40°C
•Maximum storage temperature -30°C to 50°C

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.13/17
T: +32 3 293 35 50 –www.lux-lumen.com
8Service and Maintenance
8.1 Safety precautions
Read carefully the safety information in this manual. Disconnect the power
on the entire system and allow all electronic devices to discharge, and cool
down, before executing any service or maintenance.
8.2 Cleaning
The Jumbo RGBW led-bar itself
Extensive dirt, and particle build-up degrades performance, may cause
overheating can result in damaged led-unit and power supplies. Damage by
inadequate cleaning or maintenance is not covered by the Jumbo RGBW
led-bar warranty.
Never use solvents to clean the outer housing of the unit.
Never use water, or wet cloth.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.14/17
T: +32 3 293 35 50 –www.lux-lumen.com
9Warranty
9.1 Application of warranty
Warranty period
Warranty service is valid for one year from the date of purchase by the
consumer, as evidenced by invoice date given out by your point of sale.
Warranty service
Service under warranty can only be done by Lux Lumen.
Coordinates:
Lux Lumen
Kernenergiestraat 53 A
2610 Wilrijk
Belgium
Any cost of secure transportation of the Jumbo RGBW led-bar to and from
Lux Lumen service department, will be borne by the customer.
Limitations
Lux Lumen will not warrant the following:
•Periodic check-ups, maintenance and repair or replacement of parts
due to normal wear and tear.
•Consumables
•Any software
•Defects caused by modifications carried out without Lux Lumen’s
approval.
•Damage resulting from the fact that a Jumbo RGBW Led-bar is not
conforming to country specific standards or specifications in another
country that the country of purchase.
Costs incurred by Lux Lumen’s service center in making any adoptions or
modifications of a Jumbo RGBW led-bar necessary for country specific
technical or safety standards or specifications, or any other cost to adjust
the Jumbo RGBW led-bar as a result of any specifications which have
changed since the delivery of the Jumbo RGBW led-bar.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.15/17
T: +32 3 293 35 50 –www.lux-lumen.com
Warranty service is excluded if damage or defects have been caused by:
Improper use, extensive use, handling or operation of the Jumbo RGBW
Led-bar as referred to in the user manual or operator manual and/or
relevant user documents, including without limitation, incorrect storage,
dropping, excessive shocks, corrosions, dirt, water, or sand damage, if the
Jumbo RGBW Led-bar is not rated to be used in severe conditions, indicated
by its IP and IK degree, mentioned in the Jumbo RGBW Led-bar
specifications in this manual.
Repairs, modifications or cleaning carried out by a non Lux Lumen service
centre.
Use of spare parts, software or consumables, which are not compatible
with the Jumbo RGBW Led-bar.
Connecting the Jumbo RGBW Led-bar to equipment not intended to be
used with this Jumbo RGBW Led-bar.
Defects caused by improper condition of the power supply network.
Inadequate packaging of the Jumbo RGBW Led-bar when returning it under
the RMA procedure.
Accidents or disasters or any cause beyond the control of Lux Lumen,
including but not limited to lightning, water, fire, public disturbances,
improper ventilation, and acts of god.
Others
It is the responsibility of the customer to backup and save any software
files and programs before repair and to restore the same after such repair.
This warranty does not affect the consumer’s statutory rights under
applicable national legislation in force, nor the consumer’s rights against
the retailer arising from the sales/purchase contract. In the absence of
applicable national legislation, this warranty will be the consumer’s sole and
exclusive remedy, and Lux Lumen cannot be liable for any incidental or
consequential damages for breach of any express or implied warranty of
this Jumbo RGBW Led-bar.
For full details of the warranty offered on this Jumbo RGBW Led-bar, please
contact Lux Lumen’s service center.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.16/17
T: +32 3 293 35 50 –www.lux-lumen.com
9.2 RMA procedure
To send material back to Lux Lumen, you need a RMA (Return Material
Authorization) document that you will receive from Lux Lumen.
Without the RMA document, we cannot accept the material.
The procedure to obtain a RMA:
Step 1:
Customer contacts Lux Lumen about warranty, defects if material has to be
returned.
Step 2:
Lux Lumen sends the customer a filled out RMA document (using a unique
RMA number)
Step 3:
Customer sends material (include a copy of the RMA document with the
material)
Step 4:
Lux Lumen evaluates and informs the client if repair is under warranty, or –
if not - makes an offer for repair to the client.

Jumbo LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.17/17
T: +32 3 293 35 50 –www.lux-lumen.com
10 List of used abbreviations
•AC: Alternating current
•DC: Direct current
•°F: Temperature in degrees Fahrenheit
•°C: Temperature in degrees Celsius
•LED: Light Emitting Diode
•CRI: Color Rendering Index
•RGBW: Red Green Blue White
•FWHM: Full Width Half Measurement
•RMA: Return Material Authorization
•LVD: Low Voltage Directive
•EMC: ElectroMagnetic Compatibility
Other manuals for Jumbo
1
Table of contents
Other LUX LUMEN Lighting Equipment manuals

LUX LUMEN
LUX LUMEN StarPoint User manual

LUX LUMEN
LUX LUMEN StarPole User manual

LUX LUMEN
LUX LUMEN BigEye User manual

LUX LUMEN
LUX LUMEN StarWay User manual

LUX LUMEN
LUX LUMEN StarPole User manual

LUX LUMEN
LUX LUMEN 24ch LED Driver User manual

LUX LUMEN
LUX LUMEN StarEye User manual

LUX LUMEN
LUX LUMEN SquareEyeSpot User manual

LUX LUMEN
LUX LUMEN StarEye User manual

LUX LUMEN
LUX LUMEN StarEye Maxi RGBW User manual