LUX LUMEN PowerEye User manual

PowerEye
IP67
Order code: 10691
Order code: 10692

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.2/16
T: +32 3 293 35 50 –www.lux-lumen.com
CONTENTS
1PICTURE ..................................................................................3
1.1 GENERAL........................................................................................ 3
1.2 RANGE OF LENSES .............................................................................. 3
2DIMENSIONS .............................................................................4
3SAFETY INFORMATION .................................................................5
3.1 SYMBOLS ....................................................................................... 5
3.2 PROTECTION FROM ELECTRIC SHOCK ........................................................... 6
3.3 PROTECTIONS FROM FIRE AND BURNS .......................................................... 6
3.4 PROTECTION FROM INJURY ..................................................................... 7
3.5 DISPOSING OF THIS PRODUCT ................................................................... 7
4PHYSICAL INSTALLATION ..............................................................8
4.1 UNPACKING ..................................................................................... 8
4.2 MOUNTING...................................................................................... 8
4.3 LOCATION AND ORIENTATION ................................................................... 8
5EXTERNAL CONNECTIONS .............................................................9
5.1 CURRENT POWER INPUT ........................................................................ 9
6EMC AND SAFETY REQUIREMENTS.................................................10
7INSTALLATION SETUP ................................................................11
7.1 SPECIFICATION................................................................................ 11
8SERVICE AND MAINTENANCE .......................................................12
8.1 SAFETY PRECAUTIONS ........................................................................ 12
8.2 CLEANING ..................................................................................... 12
9WARRANTY.............................................................................13
9.1 APPLICATION OF WARRANTY .................................................................. 13
9.2 RMA PROCEDURE............................................................................. 15
10 LIST OF USED ABBREVIATIONS......................................................16

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.3/16
T: +32 3 293 35 50 –www.lux-lumen.com
1Picture
1.1 General
PowerEye on bracket (included) Switched on
1.2 Range of lenses
37° 51°
Spot Medium

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.4/16
T: +32 3 293 35 50 –www.lux-lumen.com
2Dimensions

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.5/16
T: +32 3 293 35 50 –www.lux-lumen.com
3Safety information
Before installing, powering up, or servicing the PowerEye led-unit, it is highly
recommended that you read this manual and ensure yourself that you
completely understand its content. Observe the safety precautions in this
manual. Install and operate the led-unit only as described in this manual,
and in conformity with local regulations. If you have any questions how to
operate this product safely, please contact your point of sale.
3.1 Symbols
Following symbols are used to identify important safety information on the
product and in this manual.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.6/16
T: +32 3 293 35 50 –www.lux-lumen.com
3.2 Protection from electric shock
Although this device itself does not operate with dangerous voltages, the
installation in which is intended to be used, can contain dangerous voltages.
Shut down the power of the complete installation before carrying out any
installation, or maintenance work.
Use only AC to DC power sources, suitable for the application, and conform
to local regulations. Please ensure yourself that the AC to DC power supply
is able to deliver the rated current requirements of the installation.
If any cable, seal or housing is damaged, cracked, or reformed, disconnect
the power of the installation immediately.
For any additional servicing, not described in this manual, please contact
your point of sale.
3.3 Protections from fire and burns
Do not operate this led-unit if ambient temperature is over 45 °C (113 °F).
Please ensure yourself that sufficient ventilation around the led-unit is
possible.
It might be necessary to allow the led-unit to cool down for 5 minutes,
before servicing.
Do not modify the LED fixture, in a way, not described in this manual.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.7/16
T: +32 3 293 35 50 –www.lux-lumen.com
3.4 Protection from injury
Ensure yourself that the led-unit and all its accessories are securely
fastened. Verify that the led-unit is firmly fixed to its supporting
underground.
3.5 Disposing of this product
This led-lighting device is manufactured in compliance with directive of the
European community: waste electrical and electronically equipment. Please
help to preserve our environment and ensure that this product will be
recycled properly at the end of its life.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.8/16
T: +32 3 293 35 50 –www.lux-lumen.com
4Physical installation
Thank you for selecting this PowerEye led-unit as best solution in your
setup.
Warning! Read the safety precautions in this manual before integrating this
led-unit into your installation.
Installation must be carried out by qualified professionals only.
Assure yourself that there is sufficient and unrestricted air flow around the
PowerEye led-unit.
4.1 Unpacking
The following items are included in your package:
•LED fixture with focussing bracket included
•Protective antistatic packaging, with short form manual
4.2 Mounting
Surface mounting
The PowerEye led-unit can be mounted on all kind of non combustible
materials, but take in consideration that the module can have a Tc of
approx 30 °C higher as ambient temperature.
In case of problems, or doubts, please contact your point of sale.
4.3 Location and orientation
This led-unit can be used in all directions.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.9/16
T: +32 3 293 35 50 –www.lux-lumen.com
5External connections
5.1 Current power input
Safety precautions
Never connect the live power on the input terminals of the PowerEye led-
unit!
In case of doubts, contact your point of sale.
Polarity
The PowerEye led-unit is polarity sensitive. So observe polarity and cabling:
•Black inner 1 = positive
•Black inner 2 = negative
Improper connection might damage the PowerEye led-unit and power
supply permanently. In case of inversed polarity, the warranty is void.
Power supply: Rated current
The PowerEye LED fixture uses 1600mA current.
Please note, never apply a 12 V or 24 V DC to the units. This will damage the
units permanently.
Preferred IP67 1-10V dimmable power supply:
➢Mean Well ELG-75-C1400B
•Max. PowerEye led units:1 pc
•Order code: 24183
Applying power
Make sure to connect the PowerEye led unit first, before applying power,
otherwise the PowerEye led unit can be damaged.
Cable
Please ensure yourself that the cable end is watertight sealed at the
connection. If this is not properly done, water can pass through the inner
conductors of the cable and damage the internal electronics of the
PowerEye led-unit.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.10/16
T: +32 3 293 35 50 –www.lux-lumen.com
6EMC and safety requirements
The PowerEye led-unit is fully compliant to the LVD and EMC directive of the
European council, if used in a properly designed setup.
The PowerEye led-unit is only intended to be used in lighting applications,
and as such, the complete assembly of led-unit and power supply needs to
be fully compliant with following harmonized standards:
LVD requirements of the power supply
•EN 60598: general requirements of lighting equipment.
EMC requirements of the power supply
Immunity according to:
•EN 61547:2009 (General EMC immunity requirements lighting eq.)
•EN 61000-4-1:2006 (General immunity testing techniques)
•EN 61000-4-2:2008 (ESD immunity test)
•EN 61000-4-3:2006 + A1:2007 (Radiated immunity test)
•EN 61000-4-4:2004 (Fast transients and burst immunity)
•EN 61000-4-5:2005 (Surge immunity test)
•EN 61000-4-6:2008 (Conducted immunity test)
•EN 61000-4-8:1993 (Magnetic field immunity test)
•EN 61000-4-11:2004 (Voltage variations immunity test)
•EN 61000-6-1:2005 (Generic standards for immunity)
Emission according to:
•EN 61000-3-2:2005+A1:2008+A2:2009 (Harmonics emission
test<16A)
•EN 61000-3-3:2008 (Flicker+ voltage changes limits< 16A)
•EN 55015:2006+A2:2009 (Conducted + radiated emission lighting
equipment)
To achieve this compliance, a proper power supply must be supplied. In
case of doubts, contact your point of sale.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.11/16
T: +32 3 293 35 50 –www.lux-lumen.com
7Installation setup
7.1 Specification
The PowerEye led-unit is especially designed for applications where a high
light output is wished for, as in architectural environments.
The ingress protection of this PowerEye led-unit is IP67, and as such, the
unit can be used in outdoor as well as indoor applications.
The housing is made out of anodized aluminum.
RAL colors are not available.
It uses current controlled power supply, able to supply 1600mA
•Power consumption: max. 50 Watt
•Power voltage: Do not apply voltage sources!
•Current: max. 1600mA (full rated output)
•Weight: 2100 gr
•Different lenses are possible:
oSpot: 37° (FWHM)
oMedium: 51° (FWHM)
•Different white light colors are possible:
oWarm white: 2200K CRI: 80
oWarm white: 2700K CRI: 80
oWarm white: 3000K CRI: 80
oNeutral white: 4000K CRI: 80
oCold white: 5000K CRI: 80
oCold white: 6500K CRI: 70
oContact us for high CRI leds

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.12/16
T: +32 3 293 35 50 –www.lux-lumen.com
8Service and maintenance
8.1 Safety precautions
Read carefully the safety information in this manual. Lock out the power on
the entire system and allow all electronic devices to discharge, and cool
down, before executing any service or maintenance.
8.2 Cleaning
The PowerEye led-unit itself:
Extensive dirt, and particle build-up degrades performance, may cause
overheating can result in damaged led-unit and power supplies. Damage by
inadequate cleaning or maintenance is not covered by the product
warranty.
Never use solvents to clean the outer housing of the unit.
Never use water, or wet cloth.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.13/16
T: +32 3 293 35 50 –www.lux-lumen.com
9Warranty
9.1 Application of warranty
Warranty period
Warranty service is valid for one year from the date of purchase by the
consumer, as evidenced by invoice date given out by your point of sale.
Warranty service
Service under warranty can only be done by Lux Lumen.
Coordinates:
Lux Lumen
Kernenergiestraat 53 A
2610 Wilrijk
Belgium
Any cost of secure transportation of the product to and from Lux Lumen
service department, will be borne by the customer.
Limitations
Lux Lumen will not warrant the following:
•Periodic check-ups, maintenance and repair or replacement of parts
due to normal wear and tear.
•Consumables
•Any software
•Defects caused by modifications carried out without Lux Lumen’s
approval.
•Damage resulting from the fact that a product is not conforming to
country specific standards or specifications in another country that
the country of purchase.
Costs incurred by Lux Lumen’s service center in making any adoptions or
modifications of a product necessary for country specific technical or
safety standards or specifications, or any other cost to adjust the product
as a result of any specifications which have changed since the delivery of
the product.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.14/16
T: +32 3 293 35 50 –www.lux-lumen.com
Warranty service is excluded if damage or defects have been caused by:
Improper use, extensive use, handling or operation of the product as
referred to in the user manual or operator manual and/or relevant user
documents, including without limitation, incorrect storage, dropping,
excessive shocks, corrosions, dirt, water, or sand damage, if the product is
not rated to be used in severe conditions, indicated by its IP and IK degree,
mentioned in the product specifications in this manual.
Repairs, modifications or cleaning carried out by a non Lux Lumen service
centre.
Use of spare parts, software or consumables, which are not compatible
with the product.
Connecting the product to equipment not intended to be used with this
product.
Defects caused by improper condition of the power supply network.
Inadequate packaging of the product when returning it under the RMA
procedure.
Accidents or disasters or any cause beyond the control of Lux Lumen,
including but not limited to lightning, water, fire, public disturbances,
improper ventilation, and acts of god.
Others
It is the responsibility of the customer to backup and save any software
files and programs before repair and to restore the same after such repair.
This warranty does not affect the consumer’s statutory rights under
applicable national legislation in force, nor the consumer’s rights against
the retailer arising from the sales/purchase contract. In the absence of
applicable national legislation, this warranty will be the consumer’s sole and
exclusive remedy, and Lux Lumen cannot be liable for any incidental or
consequential damages for breach of any express or implied warranty of
this product.
For full details of the warranty offered on this product, please contact Lux
Lumen’s service center.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.15/16
T: +32 3 293 35 50 –www.lux-lumen.com
9.2 RMA procedure
To send material back to Lux Lumen, you need a RMA (Return Material
Authorization) document that you will receive from Lux Lumen.
Without the RMA document, we cannot accept the material.
The procedure to obtain a RMA:
Step 1:
Customer contacts Lux Lumen about warranty, defects if material has to be
returned.
Step 2:
Lux Lumen sends the customer a filled out RMA document (using a unique
RMA number)
Step 3:
Customer sends material (include a copy of the RMA document with the
material)
Step 4:
Lux Lumen evaluates and informs the client if repair is under warranty, or –
if not - makes an offer for repair to the client.

PowerEye LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.16/16
T: +32 3 293 35 50 –www.lux-lumen.com
10 List of used abbreviations
•AC: Alternating current
•DC: Direct current
•°F: Temperature in degrees Fahrenheit
•°C: Temperature in degrees Celsius
•LED: Light Emitting Diode
•CRI: Color Rendering Index
•RMA: Return Material Authorization
•LVD: Low Voltage Directive
•EMC: ElectroMagnetic Compatibility
Table of contents
Other LUX LUMEN Lighting Equipment manuals

LUX LUMEN
LUX LUMEN StarLine User manual

LUX LUMEN
LUX LUMEN StarEye Maxi User manual

LUX LUMEN
LUX LUMEN StarEye Maxi RGBW User manual

LUX LUMEN
LUX LUMEN StarPoint User manual

LUX LUMEN
LUX LUMEN 24ch LED Driver User manual

LUX LUMEN
LUX LUMEN StarPole User manual

LUX LUMEN
LUX LUMEN StarPole User manual

LUX LUMEN
LUX LUMEN StarEye User manual

LUX LUMEN
LUX LUMEN Jumbo User manual

LUX LUMEN
LUX LUMEN BigEye User manual