M-system MDP-PM User manual

MDP-PM
P. 1 / 3EM-8115 Rev.7
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
LIGHTNING SURGE PROTECTOR FOR
POTENTIOMETER USE MODEL MDP-PM
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Surge protector ............................................................. (1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
LIMITATION APPLICABLE TO M-RESTER
The M-Rester will protect electronics equipment from
damage caused by lightning by absorbing most of the
surge voltages.
However, M-Rester may not be effective against certain
extremely high voltages caused by a direct or almost di-
rect hit by lightning.
M-Rester must be installed according to this installation
/ instruction manual.
CAUTION (DISCHARGE CAPACITY)
The discharge capacity
of this unit has been in-
creased to 5000 Amps.
However, using an older
style base socket with
any upgraded head ele-
ment could decrease the
overall effectiveness of
the unit.
The upgraded version
element and socket are
distinguished by blue labels affixed to them. If you are re-
placing the head element only, be sure to check the label
color of the base socket that is already installed.
GENERAL
■FUNCTION & FEATURES
•Designed specically for potentiometer or slidewire cir-
cuits
•Protectspotentiometertransmittersfromlightningsurge
damage that enters on the wiring between the potentiom-
eter and the transmitter
•Absorbs surges only without affecting instrumentation
signal
•
No interruption of signal by unplugging the protector element
■SPECIFICATIONS
POINTS OF CAUTION
■ENVIRONMENT
•Whenheavydustormetalparticlesarepresentintheair,
install the surge protector inside proper housing with suf-
ficient ventilation.
•Donotinstallthesurgeprotectorwhereitissubjectedto
continuousvibration.Donotsubjecttheunittophysical
impact.
•Environmental temperaturemustbe within-5to+55°C
(23to131°F)withrelativehumiditywithin30to90%RH
in order to ensure adequate life span and operation.
■DIELECTRIC STRENGTH TEST
•Loosenthescrewlocatedattheleft-centeroftheelement
and remove the element module from the base before
conducting a dielectric strength testing. Otherwise the
element will start discharging at a voltage exceeding the
max. continuous operating voltage (Uc), which can cause
insulation failure of the module.
Be sure to return the element and fasten securely after
the test.
■AND ....
•We recommend that you keep spare surge protectors so
that you can replace them when necessary.
•Lightning surge canenter notonly through signal lines
butalsothroughpowersupplylines.Werecommendthat
you also use the surge protectors for power line for suf-
ficient protection.
M•RESTER
New Element Label
Blue: 5000A
(Black: 2000A)
New Base Label
Blue: 5000A
(White: 2000A)
LINE TO LINE
LINE TO
EARTH
Max. continuous ±7.5V 7.5V ±140V
operating voltage (Uc)
B – C B or C – A
Voltage protection level
±16V max 16V max ±650V max
(Up) @1kV (100A) 2 – 3 2 or 3 – 1
Voltage protection level
±25V max 25V max ±800V max
(Up) @2kV (1kA) 2 – 3 2 or 3 – 1
Leakagecurrent ≤10µA ≤10µA ≤10µA
@±7.5VDC
 @7.5VDC @±140VDC
B – C B or C – A
Capacitance@1MHz ≤2000pF ≤100pF
Responsetime ≤0.1microsecond
Max. discharge current
 5000A(8/20µs) 
(Imax)
Nominal current (IN) 100mA
Internal series resistance
 10Ω±0.1%,30ppm/°C(17ppm/°F)
MDP-PM
P. 2 / 3EM-8115 Rev.7
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
INSTALLATION
In order to separate the head element from the base, loosen the screw located at the left-center of the element.
■WALL MOUNTING
Refer to the drawings below.
■EXTERNAL DIMENSIONS unit: mm (inch)
B
C
23
A
1
31.5 (1.24)
2–5 (.20) dia.
MTG HOLE
6–M4 SCREW
GROUND TERMINAL (G)
(used as mounting bracket)
27 (1.06)53 (2.08)
80 (3.15)
45 (1.77)
HEAD ELEMENT
BASE
80 (3.15)
90 (3.54)
100 (3.94)
■MOUNTING REQUIREMENTS unit: mm (inch)
Ground Terminal (G)
(used as mounting bracket)
Base
Element is secured to Base
with screw when M-RESTER is
shipped from Factory.
M•RESTER
MADE IN JAPAN N1430B
Lot.NO
MODEL
Head Element
Specifications
COMPONENT IDENTIFICATION
33 (1.30) MIN. 2–M4 SCREW
90 (3.54)
MDP-PM
P. 3 / 3EM-8115 Rev.7
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
TERMINAL CONNECTION
Connect the unit as in the diagram below.
Besuretocross-wire between theGroundterminal(G) and thatoftheprotected equipment.Whenthesurge protector is
connected with a device which has no ground terminal such like M-System’s, ground the M-Rester Ground terminal (G) only.
M-RESTER PROTECTED
EQUIPMENT
G
G
CROSSOVER WIRE
GROUNDING
(100 ohms or less)
A crossover wire between M-RESTER ground and the ground or
metallic housing of the equipment is required for protection.
If the protected equipment has no ground terminal, ground the
M-RESTER only.
■GROUNDING
MAINTENANCE
Check surge protectors periodically. Many cases of light-
ning are ignored, and even lightning at a far distance often
causes inductive surges.
Werecommendthatyoucheckyoursurgeprotectorabout
twice a year, before and after the rainy season. Check when-
ever you experience a strong lightning occurrence.
Checking procedure is explained in the following:
■CHECKING
WIRING
1) Make sure that wiring is done as instructed in the con-
nection diagram.
2) Make sure that the Ground terminal (G) is connected to
the metallic housing of protected equipment.
3) Make sure that the Ground terminal (G) is grounded to
earth.
DISCHARGE FUNCTION
The M-Rester Tester is available for a preliminary checking
of the surge protector’s head element.
If checking of M-Rester tester shows negative, replace the
protector.
B
G
A
2
C3
1
MDP-RB
B
G
A
2
C 3
1
MDP-RB
–
B
+
A
B
RTD XMTR
(PROTECTED EQUIPMENT)
OUTPUT
INPUT
V
U
POWER
A
B
B
RTD

Other M-system Surge Protector manuals

M-system MMA User manual

M-system

M-system MMA User manual

M-system MDP-LWA User manual

M-system

M-system MDP-LWA User manual

M-system MD7RB-FF User manual

M-system

M-system MD7RB-FF User manual

M-system MGD-24 User manual

M-system

M-system MGD-24 User manual

M-system MD6 24 Series User manual

M-system

M-system MD6 24 Series User manual

M-system MD7LC User manual

M-system

M-system MD7LC User manual

M-system MD6x-24 User manual

M-system

M-system MD6x-24 User manual

M-system MD73W User manual

M-system

M-system MD73W User manual

M-system MDPA-24 User manual

M-system

M-system MDPA-24 User manual

M-system MDR2 User manual

M-system

M-system MDR2 User manual

M-system MH-1201 User manual

M-system

M-system MH-1201 User manual

M-system MMH-1 User manual

M-system

M-system MMH-1 User manual

M-system MDP-RB User manual

M-system

M-system MDP-RB User manual

M-system MGA-100 User manual

M-system

M-system MGA-100 User manual

M-system MDCAT-A Series User manual

M-system

M-system MDCAT-A Series User manual

M-system MDK-LC User manual

M-system

M-system MDK-LC User manual

M-system MDPA-24 User manual

M-system

M-system MDPA-24 User manual

M-system MDP-100 User manual

M-system

M-system MDP-100 User manual

M-system MDP-PA User manual

M-system

M-system MDP-PA User manual

M-system MD7TC User manual

M-system

M-system MD7TC User manual

M-system MD7PM User manual

M-system

M-system MD7PM User manual

M-system MDP-4R User manual

M-system

M-system MDP-4R User manual

M-system 6SN User manual

M-system

M-system 6SN User manual

M-system MD7PA User manual

M-system

M-system MD7PA User manual

Popular Surge Protector manuals by other brands

Mitsubishi Electric LITOL LTM-125RF manual

Mitsubishi Electric

Mitsubishi Electric LITOL LTM-125RF manual

CyberPower CSHT808TC user manual

CyberPower

CyberPower CSHT808TC user manual

Speco SPTVIVP user manual

Speco

Speco SPTVIVP user manual

CPT PSC3-5 PV installation instructions

CPT

CPT PSC3-5 PV installation instructions

QVS PP114M Specification sheet

QVS

QVS PP114M Specification sheet

Leviton 51020-WMT installation instructions

Leviton

Leviton 51020-WMT installation instructions

Ilsco SSI SpecPRO CSM 32 Series manual

Ilsco

Ilsco SSI SpecPRO CSM 32 Series manual

Philips SPP1182WC Specifications

Philips

Philips SPP1182WC Specifications

Bauhn ASPP8-0723-W user guide

Bauhn

Bauhn ASPP8-0723-W user guide

CyberPower CSB404 user manual

CyberPower

CyberPower CSB404 user manual

Emerson SOLAHD STCPOE65FF quick start guide

Emerson

Emerson SOLAHD STCPOE65FF quick start guide

Panamax MFP-400 instructions

Panamax

Panamax MFP-400 instructions

RCA PS42R Important information

RCA

RCA PS42R Important information

Philips SPN5087E/10 user manual

Philips

Philips SPN5087E/10 user manual

Renkforce 1574788 operating instructions

Renkforce

Renkforce 1574788 operating instructions

Bellodigital ASTU2230 instructions

Bellodigital

Bellodigital ASTU2230 instructions

CyberPower HT705UC user manual

CyberPower

CyberPower HT705UC user manual

Furman M-85 Merit Series owner's manual

Furman

Furman M-85 Merit Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.