M-system MDP-TL User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8202 Rev.3 P. 1 / 3
INSTRUCTION MANUAL
LIGHTNING SURGE PROTECTOR
FOR TELECOMMUNICATION LINE USE MODEL MDP-TL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Surge protector....................................................................(1)
DIN rail mounting adaptor*...............................................(1)
Screws for DIN rail mounting (M4 × 8)* ...........................(2)
*Included with option code /A33
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
LIMITATION APPLICABLE TO M-RESTER
The M-RESTER will protect electronics equipment from
damage caused by lightning by absorbing most of the
surge voltages.
However, M-RESTER may not be effective against cer-
tain extremely high voltages caused by a direct or almost
direct hit by lightning.
M-RESTER must be installed according to this installa-
tion / instruction manual.
GENERAL
■FUNCTION & FEATURES
• Designed specifically to protect telecommunication equip-
ment from lightning surges entering through telecommu-
nication line network
• Easy connection to the protected equipment with modu-
lar jacks
• Connection with a telephone and a modem in parallel
• No interruption of transmission signal by unplugging the
protector element
■SPECIFICATIONS
LINE TO LINE LINE TO EARTH
Max. continuous
operating voltage (Uc)
±160V ±160V
Voltage protection level
(Up) @1kV (100A)
±650V ±900V
Voltage protection level
(Up) @2kV (1kA)
±550V ±900V
Leakage current
@±160V DC
≤ 100µA ≤ 100µA
Capacitance @1 MHz ≤ 1000 pF ≤ 100 pF
Response time ≤ 0.1 microseconds
Max. discharge current
(Imax)
Modular jack: 500A (8 / 20 µs)
Screw terminal: 1000A (8 / 20 µs)
Nominal current (IN) 500mA
Internal series resistance
≤ 0.1 Ω including return
POINTS OF CAUTION
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the surge protector inside proper housing with
sufficient ventilation.
• Do not install the surge protector where it is subjected to
continuous vibration. Do not subject the unit to physical
impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■DIELECTRIC STRENGTH TEST
• Loosen the screw located at the left-center of the element
and remove the element module from the base before
conducting a dielectric strength testing. Otherwise the
element will start discharging at a voltage exceeding the
max. continuous operating voltage (Uc), which can cause
insulation failure of the module.
Be sure to return the element and fasten securely after
the test.
■AND ....
• We recommend that you keep spare surge protectors so
that you can replace them when necessary.
• Lightning surge can enter not only through signal lines
but also through power supply lines. We recommend that
you also use the surge protectors for power line for suffi-
cient protection.
MDP-TL
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8202 Rev.3 P. 2 / 3
COMPONENT IDENTIFICATION
M•RESTER
MADE IN JAPAN N1430B
Lot.NO
MODEL
Ground Terminal (G)
(used as mounting bracket)
Base
Head Element
Specifications
Head Element is secured to Base
with screw when the surge protector
is shipped from Factory.
INSTALLATION
In order to separate the head element from the base, loosen
the screw located at the left-center of the element.
■WALL MOUNTING
Refer to the drawings below.
• EXTERNAL DIMENSIONS unit: mm (inch)
P2P1
S2S1
23.5 (.93)
80 (3.15)
2–5 (.20) dia.
MTG HOLE
90 (3.54)
100 (3.94)
4–M4 TERMINAL SCREW
GROUND TERMINAL (G)
(used as mounting bracket)
27 (1.06)53 (2.08)
80 (3.15)
45 (1.77)
HEAD ELEMENT
LINE M. J.
MODEM M. J. PHONE M. J.
BASE
• MOUNTING REQUIREMENTS unit: mm (inch)
25 (.97) min. 2–M4 SCREW
90 (3.54)
■DIN RAIL MOUNTING (Only for /A33)
1. MOUNTING ONTO THE ADAPTOR
Before DIN rail mounting, secure the mounting bracket of
MDP to the mounting adaptor with a screw provided with
this product. In this step, secure at one point.
DIN Rail Mounting Adaptor
M•RESTER
2. DIN RAIL MOUNTING
Set the base socket so that its mounting slider is at the bot-
tom. Position the upper hook at the rear side of base socket
on the DIN rail and push in the lower. When removing the
socket, push down the mounting slider utilizing a minus
screwdriver and pull.
DIN Rail Mounting Slider
35 mm wide
DIN Rail
3. GROUNDING
Secure the mounting bracket at the other point with the
other screw. In this step, secure the grounding wire togeth-
er with the screw.
M•RESTER
Solderless Te r
minal
• MOUNTING REQUIREMENTS unit: mm (inch)
8.5
(.33)
[3.3 (.13)]
DIN RAIL
35mm wide
80 (3.15)
45 (1.77)
4
(.18)
2–M4 MOUNTING SCREW
(used as ground terminal (G))
MDP-TL
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8202 Rev.3 P. 3 / 3
TERMINAL CONNECTION
Connect the unit as in the diagram below.
Be sure to cross-wire between the Ground terminal (G) and that of the protected equipment. When the surge protector is con-
nected with a device which has no ground terminal such like M-System’s (See figure below), ground the M-RESTER Ground
terminal (G) only.
TELEPHONE
SET
Base Section
Element Section
GROUND
TERMINAL
L2
L1
L2
L1
L2’
L1’
L2’
L1’
L2’
L1’
G
LINE
M. J.
MODEM
M. J.
MODEM
PHONE
M. J.
Discharge Elements
TELECOM.
LINE G
G
GROUNDING
(100Ωmax.)
CROSS WIRE
Be sure to cross-wire between G terminals of modem / telephone set
and the G terminal of the MDP-TL.
S1 P1
P2
S2
MODEM/PHONE
SCREW
TERMINALS
LINE
SCREW
TERMINALS
■GROUNDING
M-RESTER PROTECTED
EQUIPMENT
G
G
CROSSOVER WIRE
GROUNDING
(100 ohms or less)
A crossover wire between M-RESTER ground and the ground or
metallic housing of the equipment is required for protection.
If the protected equipment has no ground terminal, ground the
M-RESTER only.
When the M-RESTER is mounted with DIN Rail Mounting Adapter,
connect the grounding wire to the mounting screw of the M-RESTER.
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
MAINTENANCE
Check surge protectors periodically. Many cases of light-
ning are ignored, and even lightning at a far distance often
causes inductive surges.
We recommend that you check your surge protector about
twice a year, before and after the rainy season. Check
whenever you experience a strong lightning occurrence.
Checking procedure is explained in the following:
■CHECKING
WIRING
1) Make sure that wiring is done as instructed in the con-
nection diagram.
2) Make sure that the Ground terminal (G) is connected to
the metallic housing of protected equipment.
3) Make sure that the Ground terminal (G) is grounded to
earth.
DISCHARGE FUNCTION
The M-RESTER Tester is available for checking the ele-
ment module of this surge protector.
If you do not have one, approximate checking can be con-
ducted as following.
1) Remove all wiring connected to the surge protector when
you test the element module.
2) Check resistance across the following terminals on the
high resistance range of multimeter and confirm no con-
duction (The meter shows ≥ 100MΩ or infinite).
Terminals (S1) – (S2), (S1) – (G), (S2) – (G)
3) Check that discharging occurs across the same terminals
with a 500V DC 1000MΩ insulation tester (The tester
shows ≤ 20MΩ).
If any of the above tests shows negative, replace the pro-
tector.

Other M-system Surge Protector manuals

M-system MDK-LC User manual

M-system

M-system MDK-LC User manual

M-system MATP User manual

M-system

M-system MATP User manual

M-system MD-LC2 Service manual

M-system

M-system MD-LC2 Service manual

M-system MDP-24T User manual

M-system

M-system MDP-24T User manual

M-system MAKN User manual

M-system

M-system MAKN User manual

M-system MDCAT 5E User manual

M-system

M-system MDCAT 5E User manual

M-system MD7PA User manual

M-system

M-system MD7PA User manual

M-system MDP-65T User manual

M-system

M-system MDP-65T User manual

M-system MDP-4R User manual

M-system

M-system MDP-4R User manual

M-system MGA-100 User manual

M-system

M-system MGA-100 User manual

M-system MD7PL User manual

M-system

M-system MD7PL User manual

M-system MDP-PM User manual

M-system

M-system MDP-PM User manual

M-system MMAJ User manual

M-system

M-system MMAJ User manual

M-system MDP-RB User manual

M-system

M-system MDP-RB User manual

M-system MMH-1 User manual

M-system

M-system MMH-1 User manual

M-system MD6x-24 User manual

M-system

M-system MD6x-24 User manual

M-system MDPA-24 User manual

M-system

M-system MDPA-24 User manual

M-system MDK-24 User manual

M-system

M-system MDK-24 User manual

M-system MDH User manual

M-system

M-system MDH User manual

M-system MDP-DM3 User manual

M-system

M-system MDP-DM3 User manual

M-system MDP-D Series User manual

M-system

M-system MDP-D Series User manual

M-system MDP-SP User manual

M-system

M-system MDP-SP User manual

M-system MD7LWA User manual

M-system

M-system MD7LWA User manual

M-system MDP-LWA User manual

M-system

M-system MDP-LWA User manual

Popular Surge Protector manuals by other brands

Ditek DTK-DF240S12 user guide

Ditek

Ditek DTK-DF240S12 user guide

TPD TPD-24SLP8-RJ Users installation operation & maintenance manual

TPD

TPD TPD-24SLP8-RJ Users installation operation & maintenance manual

Philips SPP2300WC Specifications

Philips

Philips SPP2300WC Specifications

Philips SPP3226WA Specifications

Philips

Philips SPP3226WA Specifications

Wavetronix Click 65 Series Installation & quick start guide

Wavetronix

Wavetronix Click 65 Series Installation & quick start guide

Panamax PM8-GAV Specifications

Panamax

Panamax PM8-GAV Specifications

RCA PS42R Important information

RCA

RCA PS42R Important information

CyberPower 890 Specification sheet

CyberPower

CyberPower 890 Specification sheet

Hubbell Ohio Brass PDV Series installation instructions

Hubbell

Hubbell Ohio Brass PDV Series installation instructions

Progressive Industries SSP-30X instruction manual

Progressive Industries

Progressive Industries SSP-30X instruction manual

Radio Shack 6100336 user guide

Radio Shack

Radio Shack 6100336 user guide

Infinite Transtector ACP 100DR2 Series installation instructions

Infinite

Infinite Transtector ACP 100DR2 Series installation instructions

GE 62690 user manual

GE

GE 62690 user manual

Ilsco SSI SpecPRO SSM 28 Series manual

Ilsco

Ilsco SSI SpecPRO SSM 28 Series manual

Intermatic CD1-024R installation instructions

Intermatic

Intermatic CD1-024R installation instructions

Sport-thieme Vario instruction manual

Sport-thieme

Sport-thieme Vario instruction manual

Intermatic Smart-Guard IG2240-IMSK installation instructions

Intermatic

Intermatic Smart-Guard IG2240-IMSK installation instructions

CyberPower B615 user manual

CyberPower

CyberPower B615 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.