10VS / 10VK
P. 1 / 2 EM-0818 Rev.2
INSTRUCTION MANUAL
MODEL
10VS/10VK
SIGNALTRANSMITTER
COMPONENT IDENTIFICATION
INSTALLATION
Use Standard Rack (model: 10BX❑).
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the
connection diagram label on the unit side.
CHECKING
1) Terminal wiring: Check that all cables are correctly
connected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 10BX❑). For the DC power source, be sure that
the ripple level is within 10% p-p.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
Zero Adj.
Span Adj. Output 1
Body
Specification Label
Connection Diagram
Label
(side)
Zero Adj.
Output 2*Span Adj.
Terminal Cover
*Provided only when the second output is selected.
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner ................................................... (1)
■ MODEL NO.
Check that model No. described on specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
POINTS OF CAUTION
■ POWER INPUT RATINGS
• Power input ratings are specified by the model number
suffix code. Check the power input voltage for the unit on the
specification label.
24V DC ±10%, approx. 25mA with Voltage Output 1
approx. 45mA with Current Output 1
■ GENERAL
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing and ventilate it.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within -5 to +55°C (23
to131°F)withrelativehumiditywithin30to90%RHinorder
to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
+
–
+
–
INPUT
1
OUTPUT 1
2
7
8
+
–
OUTPUT 2
5
6
CONNECTOR
*1 output type has the output 1 connected to the
card-edge connector in parallel.
OUTPUT 2*
POWER
10VS / 10VK
P. 2 / 2 EM-0818 Rev.2
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any calibra-
tion.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■ HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure
1) – 3).
5) Go through the same procedure for Output 2. Extender
Card (model: 10EC) is required to access the Output 2
Adjustments on top of the unit maintaining electrical
connection at the rear connector.
EXTERNAL DIMENSIONS mm (inch)
130 (5.12)
3 (.12)
50 (1.97)
82 (3.23)
2–4.3 (.17) dia.
MTG HOLE TERMINAL COVER
7–M3.5 SCREW
8 (.31)
91 (3.58)
99 (3.90 )
25 (.98)
12
3
56
78
MAINTENANCE
Regular calibration procedure is explained below:
■ CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the "ADJUST-
MENT PROCEDURE" explained earlier.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

This manual suits for next models

1

Other M-system Transmitter manuals

M-system Mini-M M2RS1 User manual

M-system

M-system Mini-M M2RS1 User manual

M-system MFS2 User manual

M-system

M-system MFS2 User manual

M-system MLV User manual

M-system

M-system MLV User manual

M-system 10VF2 User manual

M-system

M-system 10VF2 User manual

M-system B5MS User manual

M-system

M-system B5MS User manual

M-system 10JRE User manual

M-system

M-system 10JRE User manual

M-system Mini-MW Series User manual

M-system

M-system Mini-MW Series User manual

M-system M5VSH User manual

M-system

M-system M5VSH User manual

M-system 10TS User manual

M-system

M-system 10TS User manual

M-system 17PE User manual

M-system

M-system 17PE User manual

M-system KCNA User manual

M-system

M-system KCNA User manual

M-system M5YV User manual

M-system

M-system M5YV User manual

M-system M5VF2 User manual

M-system

M-system M5VF2 User manual

M-system 6AC User manual

M-system

M-system 6AC User manual

M-system Mini-M M2CEC User manual

M-system

M-system Mini-M M2CEC User manual

M-system W2XM User manual

M-system

M-system W2XM User manual

M-system Mini-M M2YV User manual

M-system

M-system Mini-M M2YV User manual

M-system M6SPA User manual

M-system

M-system M6SPA User manual

M-system M5XU User manual

M-system

M-system M5XU User manual

M-system Mini-M M2REB User manual

M-system

M-system Mini-M M2REB User manual

M-system MXV User manual

M-system

M-system MXV User manual

M-system W5-UNIT User manual

M-system

M-system W5-UNIT User manual

M-system 10JV User manual

M-system

M-system 10JV User manual

M-system Mini-M M2XT2 User manual

M-system

M-system Mini-M M2XT2 User manual

Popular Transmitter manuals by other brands

Velleman K8074 Getting started guide

Velleman

Velleman K8074 Getting started guide

elero LumeroTel 2 operating instructions

elero

elero LumeroTel 2 operating instructions

Panametrics DigitalFlow XGS868i Service manual

Panametrics

Panametrics DigitalFlow XGS868i Service manual

Crystal Vision FTX202 user manual

Crystal Vision

Crystal Vision FTX202 user manual

Indexa DF-100TX operating instructions

Indexa

Indexa DF-100TX operating instructions

Ritron RQA-152M Installation and operating instruction manual

Ritron

Ritron RQA-152M Installation and operating instruction manual

RKI Instruments 65-2643RK-05-04 Operator's manual

RKI Instruments

RKI Instruments 65-2643RK-05-04 Operator's manual

WISA USB-TX manual

WISA

WISA USB-TX manual

Girsberger ATC user manual

Girsberger

Girsberger ATC user manual

Erone SETR2681AM2 manual

Erone

Erone SETR2681AM2 manual

Miller Edge MWR13 installation instructions

Miller Edge

Miller Edge MWR13 installation instructions

Evikon PluraSens E2618-O2-L user manual

Evikon

Evikon PluraSens E2618-O2-L user manual

Becker Centronic EasyControl EC415A-III Assembly and operating instructions

Becker

Becker Centronic EasyControl EC415A-III Assembly and operating instructions

Geloso G 212-TR manual

Geloso

Geloso G 212-TR manual

APG PT-500 Series user manual

APG

APG PT-500 Series user manual

Hallicrafters HT-44 Operating and service instructions

Hallicrafters

Hallicrafters HT-44 Operating and service instructions

AMP VT30SC Operation manual

AMP

AMP VT30SC Operation manual

MMcall T10 user manual

MMcall

MMcall T10 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.