5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5131 Rev.2 P. 1 / 3
INSTRUCTION MANUAL
Mini-M™
THERMOCOUPLE TRANSMITTER
(photovoltaic system, instrument shelter) MODEL M2TT
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket + CJC sensor)......(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• This equipment is suitable for Pollution Degree 2 and In-
stallation Category II (transient voltage 2500V). Rein-
forced insulation (signal input or output to power input:
300V) and basic insulation (signal input to output: 300V)
are maintained. Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.
• The equipment must be mounted inside a suitable fire
enclosure.
• Altitude up to 2000 meters.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F).
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V rating: 85 – 264V, 47 – 66 Hz, approx. 3 – 5VA
24V DC rating: 24V ±10%, approx. 3W
11 – 27V DC rating: 11 – 27V, approx. 3W
110V DC rating: 85 – 150V, approx. 3W
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +80°C
(-4 to 176°F) with relative humidity within 10 to 90% RH
in order to ensure adequate life span and operation.
• When power up, environmental temperature must be
more than -10°C (14°F).
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
• With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to
endure it without breakdown, however, it may shorten ap-
propriate life duration.
COMPONENT IDENTIFICATION
CJC
Sensor
Model
SPAN
ZERO
Zero Adj.
Span Adj.
Body Base Socket
Connection
Diagram
Specifications
Fixing Screw
M2TT
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5131 Rev.2 P. 2 / 3
INSTALLATION
Loosen the fixing screw at the front of the unit in order to
separate the body from the base socket.
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
■DIN RAIL MOUNTING
Set the base socket so that
its DIN rail adaptor is at
the bottom. Position the
upper hook at the rear side
of base socket on the DIN
rail and push in the lower.
When removing the socket,
push down the DIN rail
adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DIMENSIONS.”
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
Attach the CJC sensor together with input wiring to the input terminals. The CJC sensor is not interchangeable. Check that
its serial number is identical to that of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
5
9
21.5 (.85)
70.5 (2.78)
84 (3.31)10 (.39) 15 (.59)
6 (.23)
59 (2.32)
DIN RAIL
35mm wide
[4 (.16)]
8–M3
SCREW
72 (2.83)
23 (.91)
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
114 (4.49)
• When mounting, no extra space is needed between units.
4
8
12
14 13
1
4 (.16)
■CONNECTION DIAGRAM
1
+
–
T / C
CJC
SENSOR
metal leg
model: CJM
comp. leadwire
5
4
+
–
+
–
OUTPUT
9
12
U(+)
V(–)
POWER
13
14
■TERMINAL ASSIGNMENTS unit: mm (inch)
8
9
12
14 13
CJC SENSOR
(model: CJM)
14 (.55)
1 14
5
M2TT
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5131 Rev.2 P. 3 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
13 – 14 with a multimeter.
3) Input: Check that the input voltage is within 0 – 100% of
full-scale.
If the thermocouple or its extension wires are broken, the
output goes over 100% (below 0% with downscale) due to
burnout function. Check leadwires in such a case.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transmitter manuals

M-system W5FV User manual

M-system

M-system W5FV User manual

M-system LINEARIZER JFX User manual

M-system

M-system LINEARIZER JFX User manual

M-system M5RS User manual

M-system

M-system M5RS User manual

M-system 6TS1 User manual

M-system

M-system 6TS1 User manual

M-system M5VSH User manual

M-system

M-system M5VSH User manual

M-system F2SP User manual

M-system

M-system F2SP User manual

M-system KC User manual

M-system

M-system KC User manual

M-system M5VF2 User manual

M-system

M-system M5VF2 User manual

M-system MLV User manual

M-system

M-system MLV User manual

M-system Mini-M M2REB User manual

M-system

M-system Mini-M M2REB User manual

M-system 15TS User manual

M-system

M-system 15TS User manual

M-system M6SXU User manual

M-system

M-system M6SXU User manual

M-system M2ADS User manual

M-system

M-system M2ADS User manual

M-system M5XV User manual

M-system

M-system M5XV User manual

M-system 10JR User manual

M-system

M-system 10JR User manual

M-system BVS User manual

M-system

M-system BVS User manual

M-system 10VS4 User manual

M-system

M-system 10VS4 User manual

M-system 10TS User manual

M-system

M-system 10TS User manual

M-system Mini-M M2AC User manual

M-system

M-system Mini-M M2AC User manual

M-system M3SXR User manual

M-system

M-system M3SXR User manual

M-system M5XTR User manual

M-system

M-system M5XTR User manual

M-system W2XT User manual

M-system

M-system W2XT User manual

M-system 10RS User manual

M-system

M-system 10RS User manual

M-system Mini-M M2SP User manual

M-system

M-system Mini-M M2SP User manual

Popular Transmitter manuals by other brands

Audiovox S1BTXA Programming guide

Audiovox

Audiovox S1BTXA Programming guide

Mitsubishi Electric PAC-SF46EPA installation manual

Mitsubishi Electric

Mitsubishi Electric PAC-SF46EPA installation manual

Pearce Simpson PANTHER SSB operating instructions

Pearce Simpson

Pearce Simpson PANTHER SSB operating instructions

NVT NV-ET1801 Complete installation guide

NVT

NVT NV-ET1801 Complete installation guide

Listen LT-82 user manual

Listen

Listen LT-82 user manual

KROHNE OPTIWAVE X500 Supplementary instructions

KROHNE

KROHNE OPTIWAVE X500 Supplementary instructions

Anywave ATSC 2KW quick start guide

Anywave

Anywave ATSC 2KW quick start guide

Ebode FM Sound user guide

Ebode

Ebode FM Sound user guide

Polytron OT 104 DFB operating manual

Polytron

Polytron OT 104 DFB operating manual

Amazilla iWing SR-HD user manual

Amazilla

Amazilla iWing SR-HD user manual

Yokis E2BP quick start guide

Yokis

Yokis E2BP quick start guide

Dwyer Instruments 648B Series Installation and operating instructions

Dwyer Instruments

Dwyer Instruments 648B Series Installation and operating instructions

EnOcean PTM 216Z user manual

EnOcean

EnOcean PTM 216Z user manual

ADDER ALIF1000 quick start guide

ADDER

ADDER ALIF1000 quick start guide

BVE AXS-FMT quick start guide

BVE

BVE AXS-FMT quick start guide

GE DigitalFlo XGM868i Service manual

GE

GE DigitalFlo XGM868i Service manual

enika P8 T 8C S quick start guide

enika

enika P8 T 8C S quick start guide

Williams Sound Personal PA PPA T35 specification

Williams Sound

Williams Sound Personal PA PPA T35 specification

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.