manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system M5XPA User manual

M-system M5XPA User manual

Other M-system Transmitter manuals

M-system W5FV User manual

M-system

M-system W5FV User manual

M-system 6BVS User manual

M-system

M-system 6BVS User manual

M-system 6M User manual

M-system

M-system 6M User manual

M-system LINEARIZER JFX User manual

M-system

M-system LINEARIZER JFX User manual

M-system Mini-M M2XU User manual

M-system

M-system Mini-M M2XU User manual

M-system B3VS/2 User manual

M-system

M-system B3VS/2 User manual

M-system 10TG User manual

M-system

M-system 10TG User manual

M-system F2VF User manual

M-system

M-system F2VF User manual

M-system M2EXV User manual

M-system

M-system M2EXV User manual

M-system M5VF User manual

M-system

M-system M5VF User manual

M-system B5MS User manual

M-system

M-system B5MS User manual

M-system W2RS User manual

M-system

M-system W2RS User manual

M-system B3HU User manual

M-system

M-system B3HU User manual

M-system FSP User manual

M-system

M-system FSP User manual

M-system CTS2 User manual

M-system

M-system CTS2 User manual

M-system 10VK User manual

M-system

M-system 10VK User manual

M-system KWVS2 User manual

M-system

M-system KWVS2 User manual

M-system 99SVA User manual

M-system

M-system 99SVA User manual

M-system M5VSH User manual

M-system

M-system M5VSH User manual

M-system FJR User manual

M-system

M-system FJR User manual

M-system 10AC User manual

M-system

M-system 10AC User manual

M-system JPA2 User manual

M-system

M-system JPA2 User manual

M-system LC User manual

M-system

M-system LC User manual

M-system Mini-M M2DU User manual

M-system

M-system Mini-M M2DU User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2772 P. 1 / 4
INSTRUCTION MANUAL
FREQUENCY TRANSMITTER
(PC programmable) MODEL M5XPA
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The M5XPA is programmable using the PC Configurator
Software. For detailed information on the PC configuration,
refer to the M5CFG users manual. The M5CFG PC Con-
figurator Software is downloadable at M-System’s web site:
https://www.m-system.co.jp
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures* to ensure the CE con-
formity.
* For example, installation of noise filters and clamp fil-
ters for the power source, input and output connected
to the unit, etc.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, ≤ 1W
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +65°C
(-4 to +149°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
TerminalCover
PowerIndicatorLED
ConfiguratorJack
Body
Specification
OutputSettingDIPSW
InputSettingDIPSW
M5XPA
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2772 P. 2 / 4
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN rail
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor using a minus screwdriv-
er.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
Slider
C
B
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm [inch]
94 [3.70]3 [.12]
25 [.98] 41 [1.61] (3.3 [.13])
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 [.29]
12
34
56
78
■CONNECTION DIAGRAM
+
–
INPUT
POWER
+
–
OUTPUT
7
8
3
4
5
6
Input Connection Examples
3
4
■ Open Collector
or Mechanical Contact
1.1kΩ
+3.3V
■ Voltage Pulse
3
4
U (+)
V (–)
-
+
-
+
CONFIGURATOR JACK
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
M5XPA
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2772 P. 3 / 4
EXTERNAL VIEWS
■LEFT VIEW ■FRONT VIEW
Output Setting
DIP SW
1
2
3
4
5
6
SW1
On
Input Setting
DIP SW
1
2
3
4
5
6SW2
On
■RIGHT VIEW
Power Indicator LED
Configurator Jack
OUTPUT RANGING
The internal DIP switch setting is required to select output types before setting a precise output range using PC Configurator
Software (model: M5CFG).
For detailed information on the PC configuration, refer to the M5CFG users manual.
Table 1. DIP switch setting: Output type
Output Type SW1
123456
0 – 20 mA ON OFF OFF OFF ON OFF
-5 – +5 V OFF ON ON OFF OFF ON
-10 – +10 V OFF ON OFF ON OFF ON
Table 2. DIP switch setting: Input type
Input Type SW2
123456
Open collector ON OFF OFF OFF OFF OFF
Mechanical contact
ON OFF OFF OFF ON OFF
5 V pulse OFF ON OFF OFF OFF ON
12 V pulse OFF OFF ON OFF OFF ON
24 V pulse OFF OFF OFF ON OFF ON
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Check DIP switch setting.
3) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
4) Input: Check that the input signal is within 0 – 100% of
the full-scale.
5) Output: Check that the load resistance meets the de-
scribed specifications.
POWER INDICATOR LED
The transmitter is provided with a power indicator LED
which blinks in different patterns indicating various oper-
ating status.
The following figure indicates typical patterns.
LEDONOFFPATTERNSTRANSMITTERSTATUS
Downloadingthesetting
Rangesetting
Fineadjusting
Supplyingafixedoutput
Normal
AbnormalOperation
(corruptionofconfigurationdata)
80ms
M5XPA
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2772 P. 4 / 4
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit using the PC Configurator
Software (model: M5CFG).
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.