manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system M5XWTU User manual

M-system M5XWTU User manual

Other M-system Transmitter manuals

M-system Mini-M M2XM2 User manual

M-system

M-system Mini-M M2XM2 User manual

M-system M2LPM User manual

M-system

M-system M2LPM User manual

M-system 10MS User manual

M-system

M-system 10MS User manual

M-system 6PA User manual

M-system

M-system 6PA User manual

M-system W5PA User manual

M-system

M-system W5PA User manual

M-system M3LR User manual

M-system

M-system M3LR User manual

M-system B3FR User manual

M-system

M-system B3FR User manual

M-system Mini-M M2VF2 User manual

M-system

M-system Mini-M M2VF2 User manual

M-system M3LR User manual

M-system

M-system M3LR User manual

M-system BVS User manual

M-system

M-system BVS User manual

M-system Mini-M M2DU User manual

M-system

M-system Mini-M M2DU User manual

M-system LINEARIZER JFX User manual

M-system

M-system LINEARIZER JFX User manual

M-system M5XU-1-R User manual

M-system

M-system M5XU-1-R User manual

M-system Mini-M M2EXR User manual

M-system

M-system Mini-M M2EXR User manual

M-system M5 Series User manual

M-system

M-system M5 Series User manual

M-system B5VS User manual

M-system

M-system B5VS User manual

M-system M3LPA User manual

M-system

M-system M3LPA User manual

M-system M5VS Series User manual

M-system

M-system M5VS Series User manual

M-system M3SXV User manual

M-system

M-system M3SXV User manual

M-system W2MS User manual

M-system

M-system W2MS User manual

M-system Mini-M M2RTS User manual

M-system

M-system Mini-M M2RTS User manual

M-system KCEC User manual

M-system

M-system KCEC User manual

M-system WRS2 User manual

M-system

M-system WRS2 User manual

M-system Mini-M M2XRP2 User manual

M-system

M-system Mini-M M2XRP2 User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 1 / 4
INSTRUCTION MANUAL
MULTI POWER TRANSMITTER
(self-powered, PC programmable) MODEL M5XWTU
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The M5XWTU is programmable using the PC Configurator
Software. For detailed information on the PC configuration,
refer to the PMCFG users manual. The PMCFG PC Con-
figurator Software is downloadable at M-System’s web site:
https://www.m-system.co.jp
Refer to EM-2768-B for the use of Modbus.
POINTS OF CAUTION
■AUXILIARY POWER
• M5XWTU does not have input terminals for auxiliary
power. The power for operation is generated from the
voltage input terminals P1 - P2, with consuming 3 VA be-
tween these terminals.
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the input
signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +65°C
(-4 to +149°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
TerminalCover
PowerIndicatorLED
ConfiguratorJack
Body
Specification
TerminatorDIPSW
forModbus
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN rail
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor using a minus screwdriv-
er.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
Slider
C
B
M5XWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 2 / 4
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm [inch]
94 [3.70]3 [.12]
25 [.98] 41 [1.61] (3.3 [.13])
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 [.29]
12
34
56
78
■CONNECTION DIAGRAM
1
8
2
4
7
1K
Current sensor
to other Modbus devices
Voltage input
COM
P2
P1
P3
3K
3
5
6
DA
DB
JACK
CONFIGURATOR
■TERMINAL CONNECTIONS
P1 P2 P3 1K 3K
sourse load
uv vu
UV VU
kl
KL
kl
KL
P1 P2 P3 1K 3K
R
sourse load
N
T
R
S
T
R
N
T
R
S
T
kl
KL
kl
KL
P1 P2 1K
R
sourse load
N
kl
KL
uv
UV
P1 P2 1K COM COM
COM
COM
R
sourse load
N
kl
KL
System/
Application
Single-phase/
2-wire
Note: Use CLSE for CT.
Grounding is unnecessary for low-voltage circuit.
  Apply voltage to P1 - P2 to generate internal power when using simplified measuring mode (fixed voltage value and power factor).
Single-phase/
3-wire
3-phase/
3-wire
Terminal System/
Appliccation Terminal
M5XWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 3 / 4
MODBUS WIRING CONNECTION
HOST PC
DA
DB
DG
SLD
FG
DA
DB
M5XWTU
Terminator*1
Terminator*1
*1. Turn the terminator DIP SW ON to use internal terminator.
■HOST PC WIRING
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
EXTERNAL VIEWS
■LEFT VIEW ■FRONT VIEW
Terminator DIP SW
for Modbus
Te rm On
Power Indicator LED
Configurator Jack
PC CONFIGURATOR
Use PC Configurator Software (model: PMCFG) to set all the parameters such as wiring type and sensor type.
Refer to the users manual for the PMCFG for detailed operation of the software program.
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Check DIP switch setting.
3) Power input voltage: Check voltage across the terminal
7 – 8 – 4 with a multimeter.
M5XWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 4 / 4
POWER INDICATOR LED
The transmitter is provided with a power indicator LED
which blinks in different patterns indicating various oper-
ating status.
The following figure indicates typical patterns.
LEDONOFFPATTERNSTRANSMITTERSTATUS
Downloadingthesetting
Looptest
Normal
AbnormalOperation
(corruptionofconfigurationdata)
80ms
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.