EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system M5XWTU User manual

M-system M5XWTU User manual

Other M-system Transmitter manuals

M-system Mini-M M2TT User manual

M-system

M-system Mini-M M2TT User manual

M-system Mini-M Series User manual

M-system

M-system Mini-M Series User manual

M-system Mini-M M2EXR User manual

M-system

M-system Mini-M M2EXR User manual

M-system W2RS1 User manual

M-system

M-system W2RS1 User manual

M-system 10VF2 User manual

M-system

M-system 10VF2 User manual

M-system MFS2 User manual

M-system

M-system MFS2 User manual

M-system Mini-M M2RS1 User manual

M-system

M-system Mini-M M2RS1 User manual

M-system M1EXM-2 User manual

M-system

M-system M1EXM-2 User manual

M-system B5RS User manual

M-system

M-system B5RS User manual

M-system Mini-M M2CA User manual

M-system

M-system Mini-M M2CA User manual

M-system 6LC User manual

M-system

M-system 6LC User manual

M-system M5PA-CA-R User manual

M-system

M-system M5PA-CA-R User manual

M-system MLV User manual

M-system

M-system MLV User manual

M-system M80YS User manual

M-system

M-system M80YS User manual

M-system 10AC User manual

M-system

M-system 10AC User manual

M-system Mini-M M2RTS User manual

M-system

M-system Mini-M M2RTS User manual

M-system MFS2 User manual

M-system

M-system MFS2 User manual

M-system Mini-M M2RS User manual

M-system

M-system Mini-M M2RS User manual

M-system B5MS User manual

M-system

M-system B5MS User manual

M-system W2VS User manual

M-system

M-system W2VS User manual

M-system 10VS User manual

M-system

M-system 10VS User manual

M-system M5RS User manual

M-system

M-system M5RS User manual

M-system M2LR User manual

M-system

M-system M2LR User manual

M-system M3LM User manual

M-system

M-system M3LM User manual

Popular Transmitter manuals by other brands

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Alinco DJ-V17T Service manual

Alinco

Alinco DJ-V17T Service manual

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

Speaka Professional 2342740 operating instructions

Speaka Professional

Speaka Professional 2342740 operating instructions

trubomat GAB 1000 instruction manual

trubomat

trubomat GAB 1000 instruction manual

Teledyne Analytical Instruments LXT-380 instructions

Teledyne Analytical Instruments

Teledyne Analytical Instruments LXT-380 instructions

Rondish UT-11 quick start guide

Rondish

Rondish UT-11 quick start guide

MG 10JRE instruction manual

MG

MG 10JRE instruction manual

Burkert 8177 operating instructions

Burkert

Burkert 8177 operating instructions

Firetide HotPort 3203 Hardware installation guide

Firetide

Firetide HotPort 3203 Hardware installation guide

Tele Radio T9-02 User instructions

Tele Radio

Tele Radio T9-02 User instructions

Rotronic HygroFlex HF3 Series user guide

Rotronic

Rotronic HygroFlex HF3 Series user guide

Jamara FCX6 Pro Tel Instruction

Jamara

Jamara FCX6 Pro Tel Instruction

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 1 / 4
INSTRUCTION MANUAL
MULTI POWER TRANSMITTER
(self-powered, PC programmable) MODEL M5XWTU
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The M5XWTU is programmable using the PC Configurator
Software. For detailed information on the PC configuration,
refer to the PMCFG users manual. The PMCFG PC Con-
figurator Software is downloadable at M-System’s web site:
https://www.m-system.co.jp
Refer to EM-2768-B for the use of Modbus.
POINTS OF CAUTION
■AUXILIARY POWER
• M5XWTU does not have input terminals for auxiliary
power. The power for operation is generated from the
voltage input terminals P1 - P2, with consuming 3 VA be-
tween these terminals.
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the input
signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +65°C
(-4 to +149°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
TerminalCover
PowerIndicatorLED
ConfiguratorJack
Body
Specification
TerminatorDIPSW
forModbus
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN rail
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor using a minus screwdriv-
er.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
Slider
C
B
M5XWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 2 / 4
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm [inch]
94 [3.70]3 [.12]
25 [.98] 41 [1.61] (3.3 [.13])
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 [.29]
12
34
56
78
■CONNECTION DIAGRAM
1
8
2
4
7
1K
Current sensor
to other Modbus devices
Voltage input
COM
P2
P1
P3
3K
3
5
6
DA
DB
JACK
CONFIGURATOR
■TERMINAL CONNECTIONS
P1 P2 P3 1K 3K
sourse load
uv vu
UV VU
kl
KL
kl
KL
P1 P2 P3 1K 3K
R
sourse load
N
T
R
S
T
R
N
T
R
S
T
kl
KL
kl
KL
P1 P2 1K
R
sourse load
N
kl
KL
uv
UV
P1 P2 1K COM COM
COM
COM
R
sourse load
N
kl
KL
System/
Application
Single-phase/
2-wire
Note: Use CLSE for CT.
Grounding is unnecessary for low-voltage circuit.
  Apply voltage to P1 - P2 to generate internal power when using simplified measuring mode (fixed voltage value and power factor).
Single-phase/
3-wire
3-phase/
3-wire
Terminal System/
Appliccation Terminal
M5XWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 3 / 4
MODBUS WIRING CONNECTION
HOST PC
DA
DB
DG
SLD
FG
DA
DB
M5XWTU
Terminator*1
Terminator*1
*1. Turn the terminator DIP SW ON to use internal terminator.
■HOST PC WIRING
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
EXTERNAL VIEWS
■LEFT VIEW ■FRONT VIEW
Terminator DIP SW
for Modbus
Te rm On
Power Indicator LED
Configurator Jack
PC CONFIGURATOR
Use PC Configurator Software (model: PMCFG) to set all the parameters such as wiring type and sensor type.
Refer to the users manual for the PMCFG for detailed operation of the software program.
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Check DIP switch setting.
3) Power input voltage: Check voltage across the terminal
7 – 8 – 4 with a multimeter.
M5XWTU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2768-A P. 4 / 4
POWER INDICATOR LED
The transmitter is provided with a power indicator LED
which blinks in different patterns indicating various oper-
ating status.
The following figure indicates typical patterns.
LEDONOFFPATTERNSTRANSMITTERSTATUS
Downloadingthesetting
Looptest
Normal
AbnormalOperation
(corruptionofconfigurationdata)
80ms
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.