BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket).............................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
AC power: Rating ±10%, 50/60 ±2 Hz, approx. 3VA
DC power: Rating ±10%, approx. 2W
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
K
-UNIT
Body Base Socket
Specifications
Zero Adj.
Span Adj.
INSTALLATION
Detach the yellow clamps located at the top and bottom of
the unit for separate the body from the base socket.
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
■DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Hang the upper hook at
the rear side of base socket on
the DIN rail and push in the
lower. When removing the
socket, push down the DIN
rail adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DI-
MENSIONS.”
ZCT TRANSMITTER
(zero-phase current transformer input) MODEL KCEZ
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3580 Rev.1 P. 1 / 2
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
3456
2187
80 (3.15)
50 (1.97) 103 (4.06)
123 (4.84) [3.3 (.13)]
80 (3.15)
20
(.79)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2
–
4.5 (.18) dia.
MTG HOLE
15 (.59) deep
8
–
M3.5
SCREW
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
+
–
OUTPUT
1
2
U(+)
V(–)
POWER
7
8
INPUT
3
4
LOAD
SOURCE
k
l
ZCT
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
Be sure to short the secondary side of ZCT or turn off the
current at its primary side for preventing the ZCT from
burning when removing this unit from a base socket.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
KCEZ
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3580 Rev.1 P. 2 / 2

Other M-system Transmitter manuals

M-system W5MS User manual

M-system

M-system W5MS User manual

M-system 10VK User manual

M-system

M-system 10VK User manual

M-system Mini-M M2UDS2 User manual

M-system

M-system Mini-M M2UDS2 User manual

M-system M3LPA2 User manual

M-system

M-system M3LPA2 User manual

M-system B5VS User manual

M-system

M-system B5VS User manual

M-system W2VS User manual

M-system

M-system W2VS User manual

M-system B5MS User manual

M-system

M-system B5MS User manual

M-system Mini-M M2UDS User manual

M-system

M-system Mini-M M2UDS User manual

M-system M1EXS-2 User manual

M-system

M-system M1EXS-2 User manual

M-system 10TG User manual

M-system

M-system 10TG User manual

M-system W2VABS User manual

M-system

M-system W2VABS User manual

M-system 6BPA User manual

M-system

M-system 6BPA User manual

M-system 10VF User manual

M-system

M-system 10VF User manual

M-system FJR User manual

M-system

M-system FJR User manual

M-system 10JFT User manual

M-system

M-system 10JFT User manual

M-system W2XM User manual

M-system

M-system W2XM User manual

M-system M2LPM User manual

M-system

M-system M2LPM User manual

M-system W5FV User manual

M-system

M-system W5FV User manual

M-system M3LR User manual

M-system

M-system M3LR User manual

M-system M5XCRS User manual

M-system

M-system M5XCRS User manual

M-system Mini-M M2TS User manual

M-system

M-system Mini-M M2TS User manual

M-system 6BLC User manual

M-system

M-system 6BLC User manual

M-system VOS2T User manual

M-system

M-system VOS2T User manual

M-system LC User manual

M-system

M-system LC User manual

Popular Transmitter manuals by other brands

Great Lakes Instruments 692P manual

Great Lakes Instruments

Great Lakes Instruments 692P manual

Meinberg DCF77 PCI511 operating instructions

Meinberg

Meinberg DCF77 PCI511 operating instructions

Chamberlain TriCode TC4 user guide

Chamberlain

Chamberlain TriCode TC4 user guide

BSi Mini-Tx UHD product manual

BSi

BSi Mini-Tx UHD product manual

Thermo Scientific Alpha pH 800 manual

Thermo Scientific

Thermo Scientific Alpha pH 800 manual

Evikon PluraSens E2670-CO user manual

Evikon

Evikon PluraSens E2670-CO user manual

Walkera WKRC-H15 user manual

Walkera

Walkera WKRC-H15 user manual

Hawk Intelligent 2000-SAN Series instruction manual

Hawk

Hawk Intelligent 2000-SAN Series instruction manual

CYP PUV-1620S-TX Operation manual

CYP

CYP PUV-1620S-TX Operation manual

dji OT-213 Product information

dji

dji OT-213 Product information

LINK-MI LM-DT200 user manual

LINK-MI

LINK-MI LM-DT200 user manual

SGM LEKTRA TC26 quick start guide

SGM LEKTRA

SGM LEKTRA TC26 quick start guide

protech T0221 manual

protech

protech T0221 manual

Bosch ATX-TRM-304T01 installation guide

Bosch

Bosch ATX-TRM-304T01 installation guide

Salcom 11-22-0000 Operator's manual

Salcom

Salcom 11-22-0000 Operator's manual

Evikon PluraSens E2670-O2 user manual

Evikon

Evikon PluraSens E2670-O2 user manual

Enersound T-588 quick start guide

Enersound

Enersound T-588 quick start guide

ATEN RCMDVI00AT user manual

ATEN

ATEN RCMDVI00AT user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.