M-system F2VS User manual

EM-5418 Rev.7 P. 1 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 80mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 30 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Zero Adj.
Span Adj.
Connection
Diagram
Specifications
Euro Type
Connector Terminal Block
INSTALLATION
Set the unit so that its DIN rail adaptor is at the bottom.
Hang the upper hook at the rear side of the unit on the DIN
rail and push in the lower. When removing the unit, push
down the DIN rail adaptor utilizing a minus screwdriver
and pull.
DIN Rail
35 mm wide
Spring Loaded
DIN Rail Adaptor
SIGNAL TRANSMITTER MODEL F2VS
F2VS
EM-5418 Rev.7 P. 2 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
1234
5678
107 (4.21) [1.5 (.06)]
DIN RAIL
35mm wide
22.5 (.89)
75 (2.95)
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
+
–
OUTPUT
5
6
+
–
INPUT
1
2
+
–
POWER
7
8
WIRING INSTRUCTIONS
■EURO TYPE CONNECTOR TERMINAL
Applicable wire size: 0.2 to 2.5 mm2
Stripped length: 7 mm
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 30 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 30 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.

Other M-system Transmitter manuals

M-system 10VF User manual

M-system

M-system 10VF User manual

M-system Mini-M M2TT User manual

M-system

M-system Mini-M M2TT User manual

M-system 10VK User manual

M-system

M-system 10VK User manual

M-system JPA2 User manual

M-system

M-system JPA2 User manual

M-system MXV User manual

M-system

M-system MXV User manual

M-system 10JT User manual

M-system

M-system 10JT User manual

M-system M3SMS User manual

M-system

M-system M3SMS User manual

M-system M3SXR User manual

M-system

M-system M3SXR User manual

M-system 6BVS User manual

M-system

M-system 6BVS User manual

M-system Mini-M Series User manual

M-system

M-system Mini-M Series User manual

M-system M5MV User manual

M-system

M-system M5MV User manual

M-system Mini-M M2AC User manual

M-system

M-system Mini-M M2AC User manual

M-system W2CA User manual

M-system

M-system W2CA User manual

M-system W2SP User manual

M-system

M-system W2SP User manual

M-system B3VS/2 User manual

M-system

M-system B3VS/2 User manual

M-system W2VABS User manual

M-system

M-system W2VABS User manual

M-system Mini-M M2PA User manual

M-system

M-system Mini-M M2PA User manual

M-system M3LU User manual

M-system

M-system M3LU User manual

M-system MXS User manual

M-system

M-system MXS User manual

M-system M3LM User manual

M-system

M-system M3LM User manual

M-system Mini-M M2XM2 User manual

M-system

M-system Mini-M M2XM2 User manual

M-system VOS2T-R User manual

M-system

M-system VOS2T-R User manual

M-system M80YS User manual

M-system

M-system M80YS User manual

M-system 6AC User manual

M-system

M-system 6AC User manual

Popular Transmitter manuals by other brands

Rosemount 702 quick start guide

Rosemount

Rosemount 702 quick start guide

Hach si792 D-FF Series quick start guide

Hach

Hach si792 D-FF Series quick start guide

Bosch RADION RFUN-A installation manual

Bosch

Bosch RADION RFUN-A installation manual

Leviton 56A00-1 installation instructions

Leviton

Leviton 56A00-1 installation instructions

Crestron DM-TX-4K-202-C Supplemental guide

Crestron

Crestron DM-TX-4K-202-C Supplemental guide

NIVELCO NIVOCAP C-200 User and programming manual

NIVELCO

NIVELCO NIVOCAP C-200 User and programming manual

K-Mate BTT001 user manual

K-Mate

K-Mate BTT001 user manual

Michell Instruments Easidew PRO XP user manual

Michell Instruments

Michell Instruments Easidew PRO XP user manual

CSI Pure Digital Fiberlink 3150 Series user manual

CSI

CSI Pure Digital Fiberlink 3150 Series user manual

Vega VEGABAR 82 operating instructions

Vega

Vega VEGABAR 82 operating instructions

RFE DS Series user manual

RFE

RFE DS Series user manual

Linear DXS-32/EC installation instructions

Linear

Linear DXS-32/EC installation instructions

MG M3-UNIT Series operating manual

MG

MG M3-UNIT Series operating manual

Emerson Rosemount 3051 Reference manual

Emerson

Emerson Rosemount 3051 Reference manual

Sennheiser BTD 300 instruction manual

Sennheiser

Sennheiser BTD 300 instruction manual

Siemens SITRANS FUS060 HART quick start

Siemens

Siemens SITRANS FUS060 HART quick start

Minco Temptran TT809 Installation and operating instructions

Minco

Minco Temptran TT809 Installation and operating instructions

Albrecht ATT 100 User instructions

Albrecht

Albrecht ATT 100 User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.