5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5397 P. 1 / 2
INSTRUCTION MANUAL
OUTPUT ISOLATOR MODEL M80YS
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Output isolator....................................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• Insert a noise filter for the input and output connected to
the unit. COSEL Noise Filter Model NAC-06-472, TDK
Noise Filter Model ZCAT 3035-1330 or equivalent is rec-
ommended.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 50mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 5 to 95% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Span Adj.
Zero Adj.
Specifications
Body
INSTALLATION
Use Installation Base (model: M80BSx).
M80YS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5397 P. 2 / 2
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
14.0 (.55)
39.2 (1.54)
50.5 (1.99) 1.3 (.05)
■CONNECTION DIAGRAM
Note: Use shielded cables for I/O wiring.
2
9
10
6
8
3
INPUT
+
–
1
OUTPUT
+
–
POWER
5
7
+
–
Installation Base
A
B
C
 
 
 
 
 
 
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input: Check the power input voltage.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transmitter manuals

M-system Mini-M M2VF2 User manual

M-system

M-system Mini-M M2VF2 User manual

M-system CTH User manual

M-system

M-system CTH User manual

M-system 6AC User manual

M-system

M-system 6AC User manual

M-system M2EXS User manual

M-system

M-system M2EXS User manual

M-system M3LT User manual

M-system

M-system M3LT User manual

M-system Mini-M M2XU User manual

M-system

M-system Mini-M M2XU User manual

M-system W2VF User manual

M-system

M-system W2VF User manual

M-system M3LM User manual

M-system

M-system M3LM User manual

M-system RB User manual

M-system

M-system RB User manual

M-system W2VABS User manual

M-system

M-system W2VABS User manual

M-system M3LM User manual

M-system

M-system M3LM User manual

M-system M6SXU User manual

M-system

M-system M6SXU User manual

M-system FJR User manual

M-system

M-system FJR User manual

M-system W2RS1 User manual

M-system

M-system W2RS1 User manual

M-system Mini-M M2EXT User manual

M-system

M-system Mini-M M2EXT User manual

M-system 6R User manual

M-system

M-system 6R User manual

M-system W2XT User manual

M-system

M-system W2XT User manual

M-system 35mm User manual

M-system

M-system 35mm User manual

M-system W5RS User manual

M-system

M-system W5RS User manual

M-system 27PM User manual

M-system

M-system 27PM User manual

M-system MXS User manual

M-system

M-system MXS User manual

M-system Mini-M M2XT2 User manual

M-system

M-system Mini-M M2XT2 User manual

M-system M5VSH User manual

M-system

M-system M5VSH User manual

M-system B3HU User manual

M-system

M-system B3HU User manual

Popular Transmitter manuals by other brands

LRS T9550 LCKG user manual

LRS

LRS T9550 LCKG user manual

Primex UK SATELLITE TRANSMITTER Installation & user guide

Primex

Primex UK SATELLITE TRANSMITTER Installation & user guide

Omega Engineering TX801R user guide

Omega Engineering

Omega Engineering TX801R user guide

Burkert 8619 multiCELL WM AC quick start

Burkert

Burkert 8619 multiCELL WM AC quick start

CYP CH-2605TXV Operation manual

CYP

CYP CH-2605TXV Operation manual

Akerstroms REMOTUS BC7400 DRIVING INSTRUCTION

Akerstroms

Akerstroms REMOTUS BC7400 DRIVING INSTRUCTION

SOR 1800PT instructions

SOR

SOR 1800PT instructions

Dakota Alert BBT-2500 user guide

Dakota Alert

Dakota Alert BBT-2500 user guide

Becker Centronic / B-Tronic EasyControl EC715 Assembly and operating instructions

Becker

Becker Centronic / B-Tronic EasyControl EC715 Assembly and operating instructions

Scott Instruments 4688IR Series Safety, Setup, Operation & Maintenance Manual

Scott Instruments

Scott Instruments 4688IR Series Safety, Setup, Operation & Maintenance Manual

MTS Systems LevelLimit Level Plus Operation manual

MTS Systems

MTS Systems LevelLimit Level Plus Operation manual

Crestron IM-WCVI Operating and installation guide

Crestron

Crestron IM-WCVI Operating and installation guide

SICK PHT operating instructions

SICK

SICK PHT operating instructions

KMT TXS instruction manual

KMT

KMT TXS instruction manual

ELRO HE887 Operation manual

ELRO

ELRO HE887 Operation manual

Airgineers Force V2 quick start guide

Airgineers

Airgineers Force V2 quick start guide

American Fibertek RTM-1485 instruction manual

American Fibertek

American Fibertek RTM-1485 instruction manual

Honeywell 5834-4 Series Installation and setup guide

Honeywell

Honeywell 5834-4 Series Installation and setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.