PT TRANSMITTER MODEL KP/KPK/KPE
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket).............................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■AUXILIARY POWER INPUT RATING & OPERATIONAL RANGE
• Locate the auxiliary power input rating marked on the
product and confirm its operational range as indicated
below:
AC power: Rating -15/+10%, 50/60 Hz, approx. 2VA
DC power: Rating ±10%, approx. 2W
or 85 – 150V, approx. 2W for 110V rating
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 85% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
K
-UNIT
Body Base Socket
Specifications
Zero Adj.
Span Adj.
INSTALLATION
Detach the yellow clamps located at the top and bottom of
the unit for separate the body from the base socket.
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
■DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Hang the upper hook at
the rear side of base socket on
the DIN rail and push in the
lower. When removing the
socket, push down the DIN
rail adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DI-
MENSIONS.”
KP / KPK / KPE
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3562 Rev.3 P. 2 / 2
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
3456
2187
80 (3.15)
50 (1.97) 103 (4.06)
123 (4.84) [3.3 (.13)]
80 (3.15)
20
(.79)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2
–
4.5 (.18) dia.
MTG HOLE
15 (.59) deep
8
–
M3.5
SCREW
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
+
–
OUTPUT
1
2
V
U
v
u
FUSE VT
LOAD
SOURCE
3
4
*
The transmitter can be powered from the input voltage when the voltage
is sufficiently stable and meets within the range of auxiliary power supply
of the unit specified in the data sheet/instruction manual.
U(+)
V(–)
AUXILIARY POWER*
7
8
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Auxiliary power input voltage: Check voltage across the
terminal 7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 120% of
the full-scale.
Be sure that the input waveform is sinusoidal to obtain
proper accuracy for model KP. For the approximate RMS
sensing type model KPK, check that the 3rd harmonic
content is 5% or less.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of suffi-
cient accuracy level. Turn the auxiliary power supply on
and warm up for more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

This manual suits for next models

2

Other M-system Transmitter manuals

M-system Mini-M M2RS User manual

M-system

M-system Mini-M M2RS User manual

M-system Mini-M M2RT User manual

M-system

M-system Mini-M M2RT User manual

M-system M2ADS User manual

M-system

M-system M2ADS User manual

M-system W2VF User manual

M-system

M-system W2VF User manual

M-system M6DVF User manual

M-system

M-system M6DVF User manual

M-system M3LLC User manual

M-system

M-system M3LLC User manual

M-system M2EXV User manual

M-system

M-system M2EXV User manual

M-system M3LT User manual

M-system

M-system M3LT User manual

M-system M2EXS User manual

M-system

M-system M2EXS User manual

M-system M5XREB User manual

M-system

M-system M5XREB User manual

M-system M1EXV-4 User manual

M-system

M-system M1EXV-4 User manual

M-system M5VF User manual

M-system

M-system M5VF User manual

M-system KCEC User manual

M-system

M-system KCEC User manual

M-system M5MS User manual

M-system

M-system M5MS User manual

M-system Mini-M Series User manual

M-system

M-system Mini-M Series User manual

M-system MXLC User manual

M-system

M-system MXLC User manual

M-system M80YS User manual

M-system

M-system M80YS User manual

M-system W2VABS User manual

M-system

M-system W2VABS User manual

M-system 17PE User manual

M-system

M-system 17PE User manual

M-system VOS2T-R User manual

M-system

M-system VOS2T-R User manual

M-system Mini-MW Series User manual

M-system

M-system Mini-MW Series User manual

M-system Mini-M M2RS1 User manual

M-system

M-system Mini-M M2RS1 User manual

M-system W5FV User manual

M-system

M-system W5FV User manual

M-system CTS2 User manual

M-system

M-system CTS2 User manual

Popular Transmitter manuals by other brands

RHEONIK RHE26 Installation & start?up guide

RHEONIK

RHEONIK RHE26 Installation & start?up guide

WIKA ls-10 operating instructions

WIKA

WIKA ls-10 operating instructions

Baker Hughes Masoneilan 12400 Series instruction manual

Baker Hughes

Baker Hughes Masoneilan 12400 Series instruction manual

Emerson PT5N Series Operating	 instruction

Emerson

Emerson PT5N Series Operating instruction

Emerson Solu Comp Xmt-P-FF/FI instruction sheet

Emerson

Emerson Solu Comp Xmt-P-FF/FI instruction sheet

Brasch BGS-ND-TRNS Installation, operating and maintenance instructions

Brasch

Brasch BGS-ND-TRNS Installation, operating and maintenance instructions

JTS PT-36BG2/5 instruction manual

JTS

JTS PT-36BG2/5 instruction manual

Konig VID-TRANS150KN manual 

Konig

Konig VID-TRANS150KN manual 

Anywave PA-560W user manual

Anywave

Anywave PA-560W user manual

MEXPO WT-300 G2 user manual

MEXPO

MEXPO WT-300 G2 user manual

SeeEyes SC-IPT1204P user guide

SeeEyes

SeeEyes SC-IPT1204P user guide

Smart Caregiver TL-2016REV Quick start instructions

Smart Caregiver

Smart Caregiver TL-2016REV Quick start instructions

evertz 7707MTA-HD manual

evertz

evertz 7707MTA-HD manual

KROHNE OPTISOUND 3010 C Handbook

KROHNE

KROHNE OPTISOUND 3010 C Handbook

TQ-Systems MODUL NO.1 Operating	 instruction

TQ-Systems

TQ-Systems MODUL NO.1 Operating instruction

Hengesbach 050D Series operating instructions

Hengesbach

Hengesbach 050D Series operating instructions

VESALA MicroSonde MPL7-33 user manual

VESALA

VESALA MicroSonde MPL7-33 user manual

Inovonics ShatterPro EE1247 Installation and operation

Inovonics

Inovonics ShatterPro EE1247 Installation and operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.