  6. •
  7. Transmitter
  8. •
  9. M-system M5XU User manual

M-system M5XU User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2763 Rev.1 P. 1 / 4
INSTRUCTION MANUAL
UNIVERSAL TRANSMITTER
(PC programmable) MODEL M5XU
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The M5XU is programmable using the PC Configurator
Software. For detailed information on the PC configuration,
refer to the M5CFG users manual. The M5CFG PC Con-
figurator Software is downloadable at M-System’s web site:
https://www.m-system.co.jp
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, ≤ 1W
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +65°C
(-4 to +149°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
TerminalCover
PowerIndicatorLED
ConfiguratorJack
Body
Specification
OutputSettingDIPSW
InputSettingDIPSW
(side)
M5XU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2763 Rev.1 P. 2 / 4
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN rail
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor using a minus screwdriv-
er.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
Slider
C
B
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm [inch]
94 [3.70]3 [.12]
25 [.98] 41 [1.61] (3.3 [.13])
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 [.29]
12
34
56
78
■CONNECTION DIAGRAM
+
–
OUTPUT
3
7
8
4
1
2
5
6
JACK
Configurator Jack
+
–POWER
+
-
Thermo-
couple
Input
DC
Current
Input
A
B
A A
B
B
A
B
B
RTD Input
2-wire 3-wire 4-wire
+
–
+
‑
3
2
1
Potentiometer
Input
Max.
Min.
M5XU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2763 Rev.1 P. 3 / 4
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
EXTERNAL VIEWS
■LEFT VIEW ■FRONT VIEW
Output Setting
DIP SW Input Setting
DIP SW
1
2
3
4
5
6
SW1
On
Power Indicator LED
Configurator Jack
1
2
3
4SW2
On
■RIGHT VIEW
OUTPUT RANGING
The internal DIP switch setting is required to select I/O types before setting a precise output range using PC Configurator
Software (model: M5CFG).
For detailed information on the PC configuration, refer to the M5CFG users manual.
Table 1. DIP switch setting: Output type
Output
Type
SW1
123456
0 – 20 mA ON OFF OFF OFF ON OFF
-5 – +5 V OFF ON ON OFF OFF ON
-10 – +10 V OFF ON OFF ON OFF ON
Input
Type
SW2
1 2 3 4
TC, RTD, POT ON OFF OFF OFF
0 – 20 mA OFF OFF ON ON
-1000 – +1000 mV DC
ON OFF OFF OFF
-10 – +10 V OFF ON ON OFF
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Check DIP switch setting.
3) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
4) Input: Check that the input signal is within 0 – 100% of
the full-scale.
5) Output: Check that the load resistance meets the de-
scribed specifications.
M5XU
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2763 Rev.1 P. 4 / 4
POWER INDICATOR LED
The transmitter is provided with a power indicator LED
which blinks in different patterns indicating various oper-
ating status.
The following figure indicates typical patterns.
LEDONOFFPATTERNSTRANSMITTERSTATUS
Downloadingthesetting
Rangesetting
Fineadjusting
Supplyingafixedoutput
Normal
AbnormalOperation
(corruptionofconfigurationdata)
80ms
Burnout
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit using the PC Configurator
Software (model: M5CFG).
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transmitter manuals

M-system 35mm User manual

M-system

M-system 35mm User manual

M-system 6BVS User manual

M-system

M-system 6BVS User manual

M-system W5LCS User manual

M-system

M-system W5LCS User manual

M-system M3SXR User manual

M-system

M-system M3SXR User manual

M-system Mini-M M2CEC User manual

M-system

M-system Mini-M M2CEC User manual

M-system W2AC User manual

M-system

M-system W2AC User manual

M-system W2RS1 User manual

M-system

M-system W2RS1 User manual

M-system M5XWTU User manual

M-system

M-system M5XWTU User manual

M-system M5XU-1-R User manual

M-system

M-system M5XU-1-R User manual

M-system VOS2T User manual

M-system

M-system VOS2T User manual

M-system 27PM User manual

M-system

M-system 27PM User manual

M-system M2EXS User manual

M-system

M-system M2EXS User manual

M-system KAC User manual

M-system

M-system KAC User manual

M-system M1EXM-2 User manual

M-system

M-system M1EXM-2 User manual

M-system 6TS1 User manual

M-system

M-system 6TS1 User manual

M-system 10JPA User manual

M-system

M-system 10JPA User manual

M-system W2VF User manual

M-system

M-system W2VF User manual

M-system Mini-M M2UDS2 User manual

M-system

M-system Mini-M M2UDS2 User manual

M-system M6SVS User manual

M-system

M-system M6SVS User manual

M-system M2XPA2 User manual

M-system

M-system M2XPA2 User manual

M-system KP User manual

M-system

M-system KP User manual

M-system Mini-M M2TG User manual

M-system

M-system Mini-M M2TG User manual

M-system Mini-M M2RS1 User manual

M-system

M-system Mini-M M2RS1 User manual

M-system 10JRE User manual

M-system

M-system 10JRE User manual

Popular Transmitter manuals by other brands

Nokeval MTR260C user manual

Nokeval

Nokeval MTR260C user manual

Bellman & Symfon BE1490 user guide

Bellman & Symfon

Bellman & Symfon BE1490 user guide

Jura Wireless Transmitter Instructions for use

Jura

Jura Wireless Transmitter Instructions for use

nedis CATR300BK quick start guide

nedis

nedis CATR300BK quick start guide

Acromag TT239-0600 user manual

Acromag

Acromag TT239-0600 user manual

Rice Lake SCT-10 Series Installation & operator's manual

Rice Lake

Rice Lake SCT-10 Series Installation & operator's manual

DMP Electronics 1139 installation guide

DMP Electronics

DMP Electronics 1139 installation guide

Novus TxIsoRail-HRT user guide

Novus

Novus TxIsoRail-HRT user guide

HETRONIC NOVA L Technical data sheet

HETRONIC

HETRONIC NOVA L Technical data sheet

Niko 05-315 quick start guide

Niko

Niko 05-315 quick start guide

Comtek BST-25 Operator's manual

Comtek

Comtek BST-25 Operator's manual

FONESTAR FO-459-TX instruction manual

FONESTAR

FONESTAR FO-459-TX instruction manual

aci ACCESS series Installation and operation instructions

aci

aci ACCESS series Installation and operation instructions

Jamara CCX Pro 2,4 GHz instructions

Jamara

Jamara CCX Pro 2,4 GHz instructions

ABB TTF200 Operating	 instruction

ABB

ABB TTF200 Operating instruction

Lightware HDMI-3D-OPT-TX210A quick start guide

Lightware

Lightware HDMI-3D-OPT-TX210A quick start guide

Nice P1S BD instructions

Nice

Nice P1S BD instructions

Dwyer Instruments 616W-2 Installation and operating instructions

Dwyer Instruments

Dwyer Instruments 616W-2 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.