PR1000IS
Intrinsically Safe Pressure and
Temperature Data Logger
PR1000IS
Product User Guide
|
2
Product Overview
The PR1000IS is an intrinsically safe pressure and
temperature data logger used to accurately monitor and
record at user programmable reading intervals. It carries
hazardous location, intrinsically safe certification in
accordance with the latest issue of:
FM3600, FM3610, CAN/CSA-C22.2 No. 60079-0:15,
CAN/CSA-C22.2 No. 60079-11:14
Certified Intrinsically Safe for:
•
Class 1 Division 1 Group ABCD
•
Class 1 Division 2 Group ABCD
•
Temperature Class: T4A
Operational Warnings
•
When used in hazardous locations, the PR1000IS is to be
installed prior to the location becoming hazardous and
removed only after the area is no longer hazardous.
•
The maximum allowed ambient temperature for the
PR1000IS (under any circumstances) is 80 °C. The
minimum rated operating temperature is -40 °C.
•
The PR1000IS is approved for use only with the Tadiran
TL-2150/S battery. Replacement with any other battery
will void the safety rating.
•
Batteries are user replaceable, but are to be removed or
replaced only in locations known to be non-hazardous.
•
Tampering or replacement of non-factory components
may adversely affect the safe use of the product, and is
prohibited. Except for replacement of the battery, the
user may not service the PR1000IS. MadgeTech, Inc. or
an authorized representative must perform all other
service to the product.
Water Resistance
The PR1000IS is fully submersible and is rated IP68.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at pacificsensortech.com.au. Follow the
instructions provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) —Follow the
instructions provided in the Installation Wizard to install
the USB Interface Drivers. Drivers can also be downloaded
from the PST website at pacificsensortech.com.au.
Ordering Information
•
902254-00 —PR1000IS-1000A, 0-1000 PSIA
•
902251-00 —PR1000IS-100A, 0-100 PSIA
•
902257-00 —PR1000IS-100G, 0-100 PSIG
•
902252-00 —PR1000IS-300A, 0-300 PSIA
•
902258-00 —PR1000IS-300G 0-300 PSIG
•
902250-00 —PR1000IS-30A, 0-30 PSIA
•
902256-00 —PR1000IS-30G, 0-30 PSIG
•
902255-00 —PR1000IS-5000A, 0-5000 PSIA
•
902253-00 —PR1000IS-500A, 0-500 PSIA
•
902259-00 —PR1000IS-500G, 0-500 PSIG
With Key Ring End Cap:
•
902284-00 —PR1000IS-1000A-KR, 0-1000 PSIA
•
902281-00 —PR1000IS-100A-KR, 0-100 PSIA
•
902287-00 —PR1000IS-100G-KR, 0-100 PSIG
•
902282-00 —PR1000IS-300A-KR, 0-300 PSIA
•
902288-00 —PR1000IS-300G-KR, 0-300 PSIG
•
902280-00 —PR1000IS-30A-KR, 0-30 PSIA
•
902286-00 —PR1000IS-30G-KR, 0-30 PSIG
•
902285-00 —PR1000IS-5000A-KR, 0-5000 PSIA
•
902283-00 —PR1000IS-500A-KR, 0-500 PSIA
•
902289-00 —PR1000IS-500G-KR, 0-500 PSIG
Accessories:
•
900319-00 —IFC400 Single Docking Station
•
900325-00 —IFC406 Multiplex Docking Station
•
901745-00 —TL-2150/S Replacement Battery
PR1000IS
Product User Guide
|
3
PRODUCT USER GUIDE
Device Operation
Connecting and Starting the Data Logger
1.
Once the software is installed and running, plug the
interface cable into the docking station (IFC400 or
IFC406).
2.
Connect the USB end of the interface cable into an
open USB port on the computer.
3.
Place the data logger into the docking station.
4.
The data logger will automatically appear under
Connected Devices within the software.
5.
For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options,
Batch
Start is used for managing multiple loggers at once,
Real Time Start
stores the dataset as it records while
connected to the logger.)
6.
The status of the device will change to Running or
Waiting to Start, depending upon your start method.
7.
Remove the data logger from the docking station and
place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1.
Place the logger into the docking station.
2.
Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3.
Once the data logger is stopped, with the logger
highlighted, click Download.
4.
Downloading will offload and save all the recorded
data to the PC.
Trigger Settings (Transient Mode)
The PR1000IS samples up to 128 Hz (7.8 ms) and begins
recording after exceeding user defined set points. After
triggering, the device will record a chosen number of
samples (Window Mode) or until reaching the stop set point
(Two Point Mode). The device can take as many as 380,928
readings with both channels enabled and 419,020 pressure
only readings. The data logger will record up to 50 samples
of “pre-trigger” data.
1.
Inthe Connected
Devices panel,
click the device
desired.
2.
On the Device Tab,
in the Information
Group, click
Properties. Or,
right-click the
device and select
Properties in the context menu.
3.
Select Trigger in the Properties window.
4.
Trigger formats are available in Window or Two Point
Mode
. Window mode allows a high and/or low trigger set
point, and a trigger sample count or “window” of time
recorded when set points are exceeded to be defined. Two
point allows for different Start and Stop set points to
bedefined for both the high and low triggers.
Refer to the Trigger Settings - MadgeTech 4 Data Logger
Software video on madgetech.com for instructions on
how to configure Trigger Settings.
Communication
To ensure desired operation of the PR1000IS, please keep the surface clear of any foreign objects or
substances. The PR1000IS’s data is downloaded through external contact with the IFC400 or IFC406 docking
station. Covering the surface with foreign objects (i.e. Calibration Labels) can prevent the communication
and/or downloading process.
PR1000IS
NEED HELP?
Device Maintenance
O-Rings
O-ring maintenance is a key factor when properly caring
for the PR1000IS. The O-rings ensure a tight seal and
prevent liquid from entering the inside of the device.
Please refer to the application note O-Rings 101:
Protecting Your Data, found at
pacificsensortech.com.au, for information on how
to prevent O-ring failure.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit
pacificsensortech.com.au/calibration.
Battery Replacement
Materials: TL-2150/S Battery
1.
Move device to a non-hazardous
location before replacing
battery.
2.
Observe Operational Warnings
when removing and replacing
the battery.
3.
Unscrew the bottom of the data
logger and remove the battery.
4.
Place the new battery into the
logger. Caution: Observe correct
battery polarity when installing.
It is important to insert the battery with the positive
polarity pointing upwards towards the sensor.
5.
Screw the cover onto the data logger.
Product Support & Troubleshooting:
•
Visit our Resources online at pacificsensortech.com.au.
•
Contact our friendly Customer Support Team at 1300 662 720 or sales@pacificsensortech.com.au.
MadgeTech 4 Software Support:
•
Refer to the built-in help section of the MadgeTech 4 Software.
•
Download the MadgeTech 4 Software Manual at pacificsensortech.com.au/madgetech-4-software.
•
Contact our friendly Customer Support Team at 1300 662 720 or sales@pacificsensortech.com.au.
AUTHORIZED DISTRIBUTOR IN AUSTRALIA
Pacific Sensor Technologies Pty Ltd
.
Unit 4, 3 Neutron Place, Rowville VIC3178 Australia
1300 662 720
sales@pacificsensortec.com.au
pacificsensortec.com.au

This manual suits for next models

40

Other MadgeTech Data Logger manuals

MadgeTech RHTemp101 User manual

MadgeTech

MadgeTech RHTemp101 User manual

MadgeTech Cryo-Temp User manual

MadgeTech

MadgeTech Cryo-Temp User manual

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech Process101A 20mA Specification sheet

MadgeTech

MadgeTech Process101A 20mA Specification sheet

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech HiTemp1400 User manual

MadgeTech

MadgeTech HiTemp1400 User manual

MadgeTech Cryo-Temp User manual

MadgeTech

MadgeTech Cryo-Temp User manual

MadgeTech Event101A User manual

MadgeTech

MadgeTech Event101A User manual

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech HiTemp140-PT User manual

MadgeTech

MadgeTech HiTemp140-PT User manual

MadgeTech UltraShock-5-EB User manual

MadgeTech

MadgeTech UltraShock-5-EB User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech RFpHTemp101A User manual

MadgeTech

MadgeTech RFpHTemp101A User manual

MadgeTech PRTemp140 Specification sheet

MadgeTech

MadgeTech PRTemp140 Specification sheet

MadgeTech PRTrans1000IS Series Specification sheet

MadgeTech

MadgeTech PRTrans1000IS Series Specification sheet

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech LyoTemp Specification sheet

MadgeTech

MadgeTech LyoTemp Specification sheet

MadgeTech Pulse101A User manual

MadgeTech

MadgeTech Pulse101A User manual

MadgeTech QuadVolt User manual

MadgeTech

MadgeTech QuadVolt User manual

Popular Data Logger manuals by other brands

Gemini Tinyview TV-0020 manual

Gemini

Gemini Tinyview TV-0020 manual

Steren 300-505 quick start guide

Steren

Steren 300-505 quick start guide

Triplett EMDL700 manual

Triplett

Triplett EMDL700 manual

wireless Seismic RT System 2 Deployment guide

wireless Seismic

wireless Seismic RT System 2 Deployment guide

METER ZL6 Replacement manual

METER

METER ZL6 Replacement manual

Huawei SmartLogger3000 Configuration guide

Huawei

Huawei SmartLogger3000 Configuration guide

Steinberg Systems SBS-DL-10 user manual

Steinberg Systems

Steinberg Systems SBS-DL-10 user manual

Extech Instruments SD910 user manual

Extech Instruments

Extech Instruments SD910 user manual

Star-Oddi DST microRF-HRT user manual

Star-Oddi

Star-Oddi DST microRF-HRT user manual

Ocea Soft Emerald user guide

Ocea Soft

Ocea Soft Emerald user guide

Intempco CX600 manual

Intempco

Intempco CX600 manual

Intech Instruments Ltd HR Series Replacement

Intech Instruments Ltd

Intech Instruments Ltd HR Series Replacement

R/Evolution AXE110P manual

R/Evolution

R/Evolution AXE110P manual

Co2meter iSense Oxygen user manual

Co2meter

Co2meter iSense Oxygen user manual

SignalFire RANGER Wall Mount manual

SignalFire

SignalFire RANGER Wall Mount manual

Duncan Solutions AutoCITE X3 Series Training Reference

Duncan Solutions

Duncan Solutions AutoCITE X3 Series Training Reference

Addi-Data MSX-ilog Series Technical description

Addi-Data

Addi-Data MSX-ilog Series Technical description

METER ZL6 quick start

METER

METER ZL6 quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.