manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech HiTemp140-PT Specification sheet

MadgeTech HiTemp140-PT Specification sheet

This manual suits for next models

10

Other MadgeTech Data Logger manuals

MadgeTech Temp1000 User manual

MadgeTech

MadgeTech Temp1000 User manual

MadgeTech QuadVolt-100mV User manual

MadgeTech

MadgeTech QuadVolt-100mV User manual

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech Bridge101A-150 User manual

MadgeTech

MadgeTech Bridge101A-150 User manual

MadgeTech CryoTemp Specification sheet

MadgeTech

MadgeTech CryoTemp Specification sheet

MadgeTech RHTemp101A Specification sheet

MadgeTech

MadgeTech RHTemp101A Specification sheet

MadgeTech Shock101-EB Specification sheet

MadgeTech

MadgeTech Shock101-EB Specification sheet

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech PR1000IS Series Specification sheet

MadgeTech

MadgeTech PR1000IS Series Specification sheet

MadgeTech TransiTemp-EC Specification sheet

MadgeTech

MadgeTech TransiTemp-EC Specification sheet

MadgeTech Temp1000P User manual

MadgeTech

MadgeTech Temp1000P User manual

MadgeTech ThermoVault Max Specification sheet

MadgeTech

MadgeTech ThermoVault Max Specification sheet

MadgeTech VFC2000 Specification sheet

MadgeTech

MadgeTech VFC2000 Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech Bridge120 User manual

MadgeTech

MadgeTech Bridge120 User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech DHS Specification sheet

MadgeTech

MadgeTech DHS Specification sheet

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech RHTemp1000IS-KR Specification sheet

MadgeTech

MadgeTech RHTemp1000IS-KR Specification sheet

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech PRTemp1000 Specification sheet

MadgeTech

MadgeTech PRTemp1000 Specification sheet

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

HiTemp140-PT
High Temperature Data Logger with
Bendable Stainless Steel Probe
IFC406 (Sold Separately)
IFC400 (Sold Separately)
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
Product User Guide | 2
HiTemp140-PT
PRODUCT USER GUIDE
Product Overview
The HiTemp140-PT is a submersible, temperature data
logger that can operate from -40 °C (-40 °F) up to +140 °C
(+284 °F) and has an accuracy of ±0.1 °C (±0.18 °F). The
device features a 12 or 24 inch bendable stainless steel
probe for measuring extended temperatures up to +350 °C
(+662 °F). The probe is durable and can be spiraled, bent or
angled in any direction, making it easy to log temperatures
within bottles, vials or other hard to reach places.
Water Resistance
The HiTemp140-PT is fully submersible and is rated IP68. It
can be placed in environments with up to 230 feet (70 m)
of water.
Bend Radius
The flexible probe on the HiTemp140-PT can be bent to
a 0.25 inch bend radius. The probe should not be bent
within 1 inch of either weld joint.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Follow the
instructions provided in the Installation Wizard to install
the USB Interface Drivers. Drivers can also be downloaded
from the MadgeTech website at madgetech.com.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running or
Waiting to Start, depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
HiTemp140-PT
PRODUCT USER GUIDE
Device Operation (cont’d)
Trigger Settings
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. Select Trigger in the Properties window.
4. Trigger formats are available in Window or Two Point
Mode. Window mode allows a high and/or low trigger set
point, and a trigger sample count or “window” of time
recorded when set points are exceeded to be defined. Two
point allows for different Start and Stop setpoints to be
defined for both the high and low triggers.
Refer to the Trigger Settings - MadgeTech 4 Data Logger
Software video on madgetech.com for instructions on
how to configure Trigger Settings.
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
O-Rings
O-ring maintenance is a key factor when properly
caring for the HiTemp140-PT. The O-rings ensure a tight
seal and prevent liquid from entering the inside of the
device. Please refer to the application note O-Rings 101:
Protecting Your Data, found at madgetech.com, for
information on how to prevent O-ring failure.
Battery Replacement
Materials: ER14250-SM Battery
1. Unscrew the bottom of the logger and remove the
battery.
2. Place the new battery into the logger. Note the polarity
of the battery. It is important to insert the battery with
positive polarity pointing upward towards the probe.
Failure to do so could result in product inoperability or
potential explosion if exposed to high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C (284 °F). Please heed the battery warning. The product will explode
if exposed to temperatures above 140 °C (284 °F).
HiTemp140-PT
NEED HELP?
DOC-1236035-00 | REV 8 2022.07.05
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
Ordering Information
HITEMP140-PT-1 PN 900230-00 Extended Range Temperature Data Logger with a 24 inch Bendable Probe with a 1 inch piercing tip
HITEMP140-PT-1-KR PN 902152-00 Extended Range Temperature Data Logger with a 24 inch Bendable Probe with a 1 inch piercing tip with key ring end cap
HiTemp140-PT-5 PN 900243-00 Extended Range Temperature Data Logger with a 24 inch Bendable Probe with a 5 inch piercing tip
HiTemp140-PT-5-KR PN 902365-00 Extended Range Temperature Data Logger with a 24 inch Bendable Probe with a 5 inch piercing tip with key ring end cap
HiTemp140-PT-1-12 PN 902306-00 Extended Range Temperature Data Logger with a 12 inch Bendable Probe with a 1 inch piercing tip
IFC400 PN 900319-00 Docking station with USB cable
IFC406 PN 900325-00 6 Port, Multiplexer docking station with USB cable
ER14250-SM
Formerly ER14250MR-145
PN 900097-00 Replacement battery for the HiTemp140-PT
For Quantity Discounts call (603) 456-2011 or email [email protected]om