manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech TC101A User manual

MadgeTech TC101A User manual

Other MadgeTech Data Logger manuals

MadgeTech EggTemp-RH User manual

MadgeTech

MadgeTech EggTemp-RH User manual

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech PR2000 Specification sheet

MadgeTech

MadgeTech PR2000 Specification sheet

MadgeTech RHTemp101A Specification sheet

MadgeTech

MadgeTech RHTemp101A Specification sheet

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech Volt101A-30V Specification sheet

MadgeTech

MadgeTech Volt101A-30V Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech Event101A User manual

MadgeTech

MadgeTech Event101A User manual

MadgeTech RFC1000 User manual

MadgeTech

MadgeTech RFC1000 User manual

MadgeTech OctProcessV2 Specification sheet

MadgeTech

MadgeTech OctProcessV2 Specification sheet

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech Volt101A-15V User manual

MadgeTech

MadgeTech Volt101A-15V User manual

MadgeTech Therm-A-lert Specification sheet

MadgeTech

MadgeTech Therm-A-lert Specification sheet

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech PRTemp1000 Specification sheet

MadgeTech

MadgeTech PRTemp1000 Specification sheet

MadgeTech Temp101 User manual

MadgeTech

MadgeTech Temp101 User manual

MadgeTech Process101A 20mA Specification sheet

MadgeTech

MadgeTech Process101A 20mA Specification sheet

MadgeTech PR140 User manual

MadgeTech

MadgeTech PR140 User manual

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech PRTrans1000 Specification sheet

MadgeTech

MadgeTech PRTrans1000 Specification sheet

MadgeTech PRHTemp2000 User manual

MadgeTech

MadgeTech PRHTemp2000 User manual

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TC101A
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1218035-00 REV 14 2013.04.02
TC101A
Thermocouple Based Temperature Recorder
Part Number TC101A
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Resolution 0.1°C (0.18°F)
Internal Channel Accuracy +0.50°C
Remote Channel Temperature Sensor,
Range, Resolution & Accuracy *See Table for Details
Cold Junction Compensation Automatic
Channels 1 internal & 1 remote
Memory 1,000,000 readings; 500,000 readings in multiple
start/stop mode or trigger settings mode
Wrap Around Yes
Sample Rate 1 second up to 24 hours
LED Indicator Red and Green
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 10 years at a 15 minute reading rate
Operating Environment –40°C to +80°C (-40°F to +176°F),
0 to 95%RH non–condensing
Material ABS plastic
Dimensions 1.4” x 2.2” x 0.6” (36mm x 56mm x 16mm)
Approvals CE
* Remote Channel Range, Resolution & Accuracy
Thermocouple Range (°C) Resolution Accuracy
J -210 to +760 0.1°C +0.5°C
K -270 to +1370 0.1°C +0.5°C
T -270 to +400 0.1°C +0.5°C
E -270 to +980 0.1°C +0.5°C
R -50 to +1760 0.5°C +2.0°C
S -50 to +1760 0.5°C +2.0°C
B +50 to +1820 0.5°C +2.0°C
N -270 to +1300 0.1°C +0.5°C
Product Information Card
Installation and Operation
Installing the software
Insert the MadgeTech 4 Software USB flash drive into an available USB port on the PC. If
the autorun does not appear, locate the drive on the computer and double click Autorun.
exe. Follow the instructions in the Wizard.
Installing the Interface Cable
- IFC200: Insert the device into a USB port. The drivers will install automatically.
Connecting the Data Logger
- Launch the MadgeTech 4 Software. Plug one end of the interface cable into the IFC200
and the opposite end into the data logger.
Starting the Data Logger
- Click Device tab in the MadgeTech 4 Software.
- The data logger should appear in the connected devices list.
- Choose the desired Start method and a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- Wait until the status of the connected data logger displays “Running” to confirm it has
started successfully.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device
is stopped. At this point the device cannot be restarted until it has been re-armed by the
computer.
Downloading data from a data logger
- Connect the data logger to the interface cable on the PC.
- Click on the device in the connected devices list, right click and select download.
Wiring the Data Logger
MP Model Wiring
The standard connector is the SMP connection which
allows for the user to insert a subminiature thermocouple
plug into the connector on the device.
ST and TB Model Wiring
The TC101A-ST and TC101A-TB have a three position
removable screw terminal. This enables the data logger
to be connected to most 3-wire thermocouples with lead
wires.
Note: Be sure to connect the thermocouple with the right polarity as marked on the device case.
The TC101A-ST and TC101A-TB have the ability to shield the thermocouple with the
ground connection. When using a 2-wire thermocouple, leave the ground input unconnected.
Product Notes
Thermocouple Type
To change the thermocouple type:
- Select the Device Menu, then Identify Device and Read Status.
- Select the Device Detail tab, then Thermocouple Type.
- Click on the Change button in the Thermocouple Type window.
- Select the correct thermocouple type from the drop down list.
- Click on the Save button to store the thermocouple type in the device then click OK.
Product Information Card
TC101A
LEDs
- Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start mode
- Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to
indicate an alarm condition
Password Protection
An optional password may be programmed into the device to restrict access to
configuration options. Data may be read out without the password.
Multiple Start/Stop Mode Activation
To start device: Press and hold the pushbutton for 5 seconds, the green LED will flash during
this time. The device has started logging.
To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash during
this time. The device has stopped logging.
Alarm and Cumulative Alarm Delay
To set an alarm, click Device Menu: Identify Device and Read Status: Device Detail Tab or
Device Menu: Start Device. Select Alarm Settings. Check the Enable Alarm Settings box
to program the alarm. Enter the high and low values into the corresponding fields. Check
the Cumulative Alarm Delay box to enable the time duration alarm. With this selected, the
device will only alarm after it has recorded the same amount of data as the time duration
of data entered. Note: Time durations between 12 hours to 23 hours, 59 minutes and 59
seconds may not be programmed. Only time durations up to 11 hours, 59 minutes and 59
seconds may be set in the hh:mm:ss field and the day field represents a 24 hour period.
Trigger Setting
The device can be programmed to only record based off user configured trigger settings.
Choose Trigger Settings from the Device Menu: Start Device or Identify Device and Read
Status. Trigger formats are available in Window and Two Point (bi-level) mode. Window
allows for one range of temperature monitoring and two point mode allows for two ranges.
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver and a Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The TC101A standard calibration is two points at 25°C and 60°C for the internal sensor and
0mV for the Thermocouple channel.
Pricing:
Recalibration traceable to NIST $70.00
Recalibration $40.00
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com.
To send the devices back, visit www.madgetech.com, select Services then RMA Process.