manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech TC101A User manual

MadgeTech TC101A User manual

TC101A
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1218035-00 REV 14 2013.04.02
TC101A
Thermocouple Based Temperature Recorder
Part Number TC101A
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Resolution 0.1°C (0.18°F)
Internal Channel Accuracy +0.50°C
Remote Channel Temperature Sensor,
Range, Resolution & Accuracy *See Table for Details
Cold Junction Compensation Automatic
Channels 1 internal & 1 remote
Memory 1,000,000 readings; 500,000 readings in multiple
start/stop mode or trigger settings mode
Wrap Around Yes
Sample Rate 1 second up to 24 hours
LED Indicator Red and Green
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 10 years at a 15 minute reading rate
Operating Environment –40°C to +80°C (-40°F to +176°F),
0 to 95%RH non–condensing
Material ABS plastic
Dimensions 1.4” x 2.2” x 0.6” (36mm x 56mm x 16mm)
Approvals CE
* Remote Channel Range, Resolution & Accuracy
Thermocouple Range (°C) Resolution Accuracy
J -210 to +760 0.1°C +0.5°C
K -270 to +1370 0.1°C +0.5°C
T -270 to +400 0.1°C +0.5°C
E -270 to +980 0.1°C +0.5°C
R -50 to +1760 0.5°C +2.0°C
S -50 to +1760 0.5°C +2.0°C
B +50 to +1820 0.5°C +2.0°C
N -270 to +1300 0.1°C +0.5°C
Product Information Card
Installation and Operation
Installing the software
Insert the MadgeTech 4 Software USB flash drive into an available USB port on the PC. If
the autorun does not appear, locate the drive on the computer and double click Autorun.
exe. Follow the instructions in the Wizard.
Installing the Interface Cable
- IFC200: Insert the device into a USB port. The drivers will install automatically.
Connecting the Data Logger
- Launch the MadgeTech 4 Software. Plug one end of the interface cable into the IFC200
and the opposite end into the data logger.
Starting the Data Logger
- Click Device tab in the MadgeTech 4 Software.
- The data logger should appear in the connected devices list.
- Choose the desired Start method and a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- Wait until the status of the connected data logger displays “Running” to confirm it has
started successfully.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device
is stopped. At this point the device cannot be restarted until it has been re-armed by the
computer.
Downloading data from a data logger
- Connect the data logger to the interface cable on the PC.
- Click on the device in the connected devices list, right click and select download.
Wiring the Data Logger
MP Model Wiring
The standard connector is the SMP connection which
allows for the user to insert a subminiature thermocouple
plug into the connector on the device.
ST and TB Model Wiring
The TC101A-ST and TC101A-TB have a three position
removable screw terminal. This enables the data logger
to be connected to most 3-wire thermocouples with lead
wires.
Note: Be sure to connect the thermocouple with the right polarity as marked on the device case.
The TC101A-ST and TC101A-TB have the ability to shield the thermocouple with the
ground connection. When using a 2-wire thermocouple, leave the ground input unconnected.
Product Notes
Thermocouple Type
To change the thermocouple type:
- Select the Device Menu, then Identify Device and Read Status.
- Select the Device Detail tab, then Thermocouple Type.
- Click on the Change button in the Thermocouple Type window.
- Select the correct thermocouple type from the drop down list.
- Click on the Save button to store the thermocouple type in the device then click OK.
Product Information Card
TC101A
LEDs
- Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start mode
- Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to
indicate an alarm condition
Password Protection
An optional password may be programmed into the device to restrict access to
configuration options. Data may be read out without the password.
Multiple Start/Stop Mode Activation
To start device: Press and hold the pushbutton for 5 seconds, the green LED will flash during
this time. The device has started logging.
To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash during
this time. The device has stopped logging.
Alarm and Cumulative Alarm Delay
To set an alarm, click Device Menu: Identify Device and Read Status: Device Detail Tab or
Device Menu: Start Device. Select Alarm Settings. Check the Enable Alarm Settings box
to program the alarm. Enter the high and low values into the corresponding fields. Check
the Cumulative Alarm Delay box to enable the time duration alarm. With this selected, the
device will only alarm after it has recorded the same amount of data as the time duration
of data entered. Note: Time durations between 12 hours to 23 hours, 59 minutes and 59
seconds may not be programmed. Only time durations up to 11 hours, 59 minutes and 59
seconds may be set in the hh:mm:ss field and the day field represents a 24 hour period.
Trigger Setting
The device can be programmed to only record based off user configured trigger settings.
Choose Trigger Settings from the Device Menu: Start Device or Identify Device and Read
Status. Trigger formats are available in Window and Two Point (bi-level) mode. Window
allows for one range of temperature monitoring and two point mode allows for two ranges.
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver and a Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The TC101A standard calibration is two points at 25°C and 60°C for the internal sensor and
0mV for the Thermocouple channel.
Pricing:
Recalibration traceable to NIST $70.00
Recalibration $40.00
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com.
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
+ Input
- Input
Connector for interface cable
+ Input
- Input
Ground
Connector for interface cable

Other MadgeTech Data Logger manuals

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech TSR101 Series User manual

MadgeTech

MadgeTech TSR101 Series User manual

MadgeTech RFVolt2000A User manual

MadgeTech

MadgeTech RFVolt2000A User manual

MadgeTech QuadRTD User manual

MadgeTech

MadgeTech QuadRTD User manual

MadgeTech UltraShock Series User manual

MadgeTech

MadgeTech UltraShock Series User manual

MadgeTech pHTemp2000 Specification sheet

MadgeTech

MadgeTech pHTemp2000 Specification sheet

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech PRTemp140 Specification sheet

MadgeTech

MadgeTech PRTemp140 Specification sheet

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech pHTemp2000 User manual

MadgeTech

MadgeTech pHTemp2000 User manual

MadgeTech AVS140-1 Specification sheet

MadgeTech

MadgeTech AVS140-1 Specification sheet

MadgeTech Process101A User manual

MadgeTech

MadgeTech Process101A User manual

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech HiTemp150 User manual

MadgeTech

MadgeTech HiTemp150 User manual

MadgeTech HiTemp140-FR Specification sheet

MadgeTech

MadgeTech HiTemp140-FR Specification sheet

MadgeTech Temp1000S User manual

MadgeTech

MadgeTech Temp1000S User manual

MadgeTech HiTemp140-FP User manual

MadgeTech

MadgeTech HiTemp140-FP User manual

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech CTL2000 User manual

MadgeTech

MadgeTech CTL2000 User manual

MadgeTech RFCurrent2000A Specification sheet

MadgeTech

MadgeTech RFCurrent2000A Specification sheet

MadgeTech MadgeNET RFTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNET RFTemp2000A Specification sheet

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech HITEMP140-PT Specification sheet

MadgeTech

MadgeTech HITEMP140-PT Specification sheet

Popular Data Logger manuals by other brands

Danelec DM100-2014 Operator's manual

Danelec

Danelec DM100-2014 Operator's manual

Omega OM-USB-2404-UI user guide

Omega

Omega OM-USB-2404-UI user guide

PCE Instruments PCE-HT 71N user guide

PCE Instruments

PCE Instruments PCE-HT 71N user guide

Steren 300-500 quick start guide

Steren

Steren 300-500 quick start guide

Arexx TL-300 manual

Arexx

Arexx TL-300 manual

Keithley KUSB-3116 Getting started manual

Keithley

Keithley KUSB-3116 Getting started manual

Fluke 1738/B user manual

Fluke

Fluke 1738/B user manual

SOLIS W4G Quick installation manual

SOLIS

SOLIS W4G Quick installation manual

Microtronics myDatalogEx user manual

Microtronics

Microtronics myDatalogEx user manual

T&D TR7 Series user manual

T&D

T&D TR7 Series user manual

EIJKELKAMP CBR user manual

EIJKELKAMP

EIJKELKAMP CBR user manual

Grosvenor IT31 user guide

Grosvenor

Grosvenor IT31 user guide

SS Telecoms SS-68BB user manual

SS Telecoms

SS Telecoms SS-68BB user manual

X2E XORAYA Z7 user manual

X2E

X2E XORAYA Z7 user manual

beadedstream D605 Installation & quick start guide

beadedstream

beadedstream D605 Installation & quick start guide

Marathon EDL-4S quick start guide

Marathon

Marathon EDL-4S quick start guide

infoAgro THI operating instructions

infoAgro

infoAgro THI operating instructions

METER ZL6 Replacement

METER

METER ZL6 Replacement

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.