MadgeTech UltraShock Series User manual

UltraShock
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
PO Box 50 lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1067035-00 REV 8 2012.02.16
Part Number UltraShock
Channels Shock (3 axes), Temperature, Humidity, Pressure
Range
*See Tables BelowResolution
Accuracy
Sample Rate 512 Hz
Reading Rate 64Hz up to 5 minutes
Memory 174,762/channel
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 7 days
Operating Environment -20 to +60°C, 0 to 95%RH (non-condensing)
Material Anodized aluminum
Dimensions 3.5” x 4.4” x 1” (89mm x 112mm x 26mm)
Approvals CE
Shock Range +5g +50g +100g +250g
Accuracy +0.2g +1.0g +2.0g +4.0g
Resolution 0.01g 0.03g 0.05g 0.2g
*Shock Acceleration Range, Resolution and Accuracy
Product Information Card
UltraShock-5
Temperature, Humidity, Pressure, and Tri-axial +5g, Shock Data Logger
UltraShock-100
Temperature, Humidity, Pressure, and Tri-axial +100g, Shock Data Logger
UltraShock-50
Temperature, Humidity, Pressure, and Tri-axial +50g, Shock Data Logger
UltraShock-250
Temperature, Humidity, Pressure, and Tri-axial +250g, Shock Data Logger
Channel Temperature Humidity Pressure
Range -20 to +60°C 0 to 95%RH 0 to 30PSIA
Accuracy +0.5°C +3%RH +1%FSR @ 25°C
Resolution 0.1°C 0.5%RH 0.002PSIA
*Acceleration Range, Resolution and Accuracy
Product Notes
Reading Intervals
The UltraShock measures pressure, temperature, humidity and tri-axial shock. When the
device is running, the shock parameter samples at 512Hz and at the user specified reading
rate, the device writes the peak values (g-force) from the samples to memory.
For Example:
Pressure, temperature and humidity readings are taken at the user specified reading rate
up to a maximum of 2 seconds intervals.
Axis Orientation
When the UltraShock is laying flat, with the label facing up, the
x-axis indicates left to right direction and will read ~0g when
still. The y-axis reads in a top to bottom direction and reads ~0g
when still. The z-axis reads perpendicular to the other two axis,
and will read ~1g when still.
Device Maintenance
Battery Replacement
Materials: 3/32” HEX Driver (Allen Key) and a Replacement Battery (U9VL-J)
- Remove the cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely. Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The UltraShock standard calibration is performed at one temperature point at 25°C, two
humidity points at 25%RH and 75%RH, two pressure points at 15PSI and 27-30PSI and 0g
for the x-axis, 0g for the y-axis and 1g for the z-axis.
Note: The shock parameters are not traceable to NIST.
Pricing:
Recalibration traceable to NIST $156.00
Recalibration $136.00
Additional Services:
As Found Data $15.00 per channel
Verification Point $15.00 per point
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
UltraShock Product Quick Reference Card
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Sampled Data: Recorded Data:
Y-Axis
Z-Axis
X-Axis

This manual suits for next models

4

Other MadgeTech Data Logger manuals

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech PRTemp140 Specification sheet

MadgeTech

MadgeTech PRTemp140 Specification sheet

MadgeTech SHOCK300 Specification sheet

MadgeTech

MadgeTech SHOCK300 Specification sheet

MadgeTech Temp101 User manual

MadgeTech

MadgeTech Temp101 User manual

MadgeTech RHTemp1000IS-KR Specification sheet

MadgeTech

MadgeTech RHTemp1000IS-KR Specification sheet

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech TransiTemp-EC Specification sheet

MadgeTech

MadgeTech TransiTemp-EC Specification sheet

MadgeTech HiTemp140-FP-6 Specification sheet

MadgeTech

MadgeTech HiTemp140-FP-6 Specification sheet

MadgeTech PR140 User manual

MadgeTech

MadgeTech PR140 User manual

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech EggTemp-RH User manual

MadgeTech

MadgeTech EggTemp-RH User manual

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech pHTemp2000 Specification sheet

MadgeTech

MadgeTech pHTemp2000 Specification sheet

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech Process101A User manual

MadgeTech

MadgeTech Process101A User manual

MadgeTech Cryo-Temp Specification sheet

MadgeTech

MadgeTech Cryo-Temp Specification sheet

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech PRHTemp101 User manual

MadgeTech

MadgeTech PRHTemp101 User manual

MadgeTech octtemp 2000 User manual

MadgeTech

MadgeTech octtemp 2000 User manual

Popular Data Logger manuals by other brands

Omega OM-CP-QUADVOLT instruction sheet

Omega

Omega OM-CP-QUADVOLT instruction sheet

Mega Electronics ME6000 Setup instructions

Mega Electronics

Mega Electronics ME6000 Setup instructions

Besantek BST-DL71 Operation manual

Besantek

Besantek BST-DL71 Operation manual

Rotronic RMS Wall mount Data Logger instruction manual

Rotronic

Rotronic RMS Wall mount Data Logger instruction manual

Ebro EBI 100 Series manual

Ebro

Ebro EBI 100 Series manual

Crane Electronics TorqueStar Lite quick start guide

Crane Electronics

Crane Electronics TorqueStar Lite quick start guide

Apogee mCACHE owner's manual

Apogee

Apogee mCACHE owner's manual

EasyLog EL-SIE quick start guide

EasyLog

EasyLog EL-SIE quick start guide

YOKOGAWA SMARTDAC+ GX10 user manual

YOKOGAWA

YOKOGAWA SMARTDAC+ GX10 user manual

BENZING EXPRESS Fancier user manual

BENZING

BENZING EXPRESS Fancier user manual

Honeywell eZtrend V5 operating manual

Honeywell

Honeywell eZtrend V5 operating manual

Panasonic LB-DH7 Series installation guide

Panasonic

Panasonic LB-DH7 Series installation guide

Onset HOBO user guide

Onset

Onset HOBO user guide

berlinger Fridge-tag Ultra Low QUICK INFO

berlinger

berlinger Fridge-tag Ultra Low QUICK INFO

VOLTCRAFT 100055 operating instructions

VOLTCRAFT

VOLTCRAFT 100055 operating instructions

Tinytag Ultra 2 user manual

Tinytag

Tinytag Ultra 2 user manual

Decagon Devices EM50 quick start guide

Decagon Devices

Decagon Devices EM50 quick start guide

NexSens Technology X2 user guide

NexSens Technology

NexSens Technology X2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.