manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech UltraShock Series User manual

MadgeTech UltraShock Series User manual

This manual suits for next models

4

Other MadgeTech Data Logger manuals

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech OctProcess Series User manual

MadgeTech

MadgeTech OctProcess Series User manual

MadgeTech HiTemp140-FP-6 Specification sheet

MadgeTech

MadgeTech HiTemp140-FP-6 Specification sheet

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech Shock101-5-EB Specification sheet

MadgeTech

MadgeTech Shock101-5-EB Specification sheet

MadgeTech Volt101A-30V Specification sheet

MadgeTech

MadgeTech Volt101A-30V Specification sheet

MadgeTech Bridge101A-150 User manual

MadgeTech

MadgeTech Bridge101A-150 User manual

MadgeTech QuadVolt User manual

MadgeTech

MadgeTech QuadVolt User manual

MadgeTech HiTemp140X2 Series User manual

MadgeTech

MadgeTech HiTemp140X2 Series User manual

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech PR2000 Specification sheet

MadgeTech

MadgeTech PR2000 Specification sheet

MadgeTech PR1000IS Series Specification sheet

MadgeTech

MadgeTech PR1000IS Series Specification sheet

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech Shock101-100 Specification sheet

MadgeTech

MadgeTech Shock101-100 Specification sheet

MadgeTech RFC1000 User manual

MadgeTech

MadgeTech RFC1000 User manual

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech TransiTemp-EC Specification sheet

MadgeTech

MadgeTech TransiTemp-EC Specification sheet

MadgeTech TCTemp1000 User manual

MadgeTech

MadgeTech TCTemp1000 User manual

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UltraShock
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
PO Box 50 lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1067035-00 REV 8 2012.02.16
Part Number UltraShock
Channels Shock (3 axes), Temperature, Humidity, Pressure
Range
*See Tables BelowResolution
Accuracy
Sample Rate 512 Hz
Reading Rate 64Hz up to 5 minutes
Memory 174,762/channel
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 7 days
Operating Environment -20 to +60°C, 0 to 95%RH (non-condensing)
Material Anodized aluminum
Dimensions 3.5” x 4.4” x 1” (89mm x 112mm x 26mm)
Approvals CE
Shock Range +5g +50g +100g +250g
Accuracy +0.2g +1.0g +2.0g +4.0g
Resolution 0.01g 0.03g 0.05g 0.2g
*Shock Acceleration Range, Resolution and Accuracy
Product Information Card
UltraShock-5
Temperature, Humidity, Pressure, and Tri-axial +5g, Shock Data Logger
UltraShock-100
Temperature, Humidity, Pressure, and Tri-axial +100g, Shock Data Logger
UltraShock-50
Temperature, Humidity, Pressure, and Tri-axial +50g, Shock Data Logger
UltraShock-250
Temperature, Humidity, Pressure, and Tri-axial +250g, Shock Data Logger
Channel Temperature Humidity Pressure
Range -20 to +60°C 0 to 95%RH 0 to 30PSIA
Accuracy +0.5°C +3%RH +1%FSR @ 25°C
Resolution 0.1°C 0.5%RH 0.002PSIA
*Acceleration Range, Resolution and Accuracy
Product Notes
Reading Intervals
The UltraShock measures pressure, temperature, humidity and tri-axial shock. When the
device is running, the shock parameter samples at 512Hz and at the user specified reading
rate, the device writes the peak values (g-force) from the samples to memory.
For Example:
Pressure, temperature and humidity readings are taken at the user specified reading rate
up to a maximum of 2 seconds intervals.
Axis Orientation
When the UltraShock is laying flat, with the label facing up, the
x-axis indicates left to right direction and will read ~0g when
still. The y-axis reads in a top to bottom direction and reads ~0g
when still. The z-axis reads perpendicular to the other two axis,
and will read ~1g when still.
Device Maintenance
Battery Replacement
Materials: 3/32” HEX Driver (Allen Key) and a Replacement Battery (U9VL-J)
- Remove the cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely. Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The UltraShock standard calibration is performed at one temperature point at 25°C, two
humidity points at 25%RH and 75%RH, two pressure points at 15PSI and 27-30PSI and 0g
for the x-axis, 0g for the y-axis and 1g for the z-axis.
Note: The shock parameters are not traceable to NIST.
Pricing:
Recalibration traceable to NIST $156.00
Recalibration $136.00
Additional Services:
As Found Data $15.00 per channel
Verification Point $15.00 per point
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
UltraShock Product Quick Reference Card
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Sampled Data: Recorded Data: