MadgeTech HiTemp140-2 Specification sheet

HiTemp140 Series
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
HiTemp140 Series
High Temperature Data Loggers
Probe lengths up to 7” available
Product User Guide
Specification HiTemp140
Temperature Sensor 100 Ωplatinum RTD
Probe Range –200 °C to +260 °C (-328 °F to +500 °F)
*BODY OF LOGGER CANNOT EXCEED 140 °C
Temperature Resolution 0.01 °C
Temperature Accuracy
±0.1 ºC/±0.18 ºF (20 ºC to +140 ºC/68 ºF to +284 ºF)
±0.3 °C/±0.54 ºF (-20 °C to +19.99 °C/-4 °F to +67.98 °F)
±0.4 °C/±0.72 ºF (-40 °C to -20.01 °C/-40 °F to -4.02 °F)
Memory 32,700 readings
Reading Rate 1 reading every second up to 1 reading every 24 hours
Required Interface Package IFC400 or IFC406
Baud Rate 125,000 baud
Typical Battery Life 1 year (1 minute reading rate at 25 °C/77 °F)
Operating Environment –40 °C to +140 °C, 0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA
BODY OF LOGGER CAN NOT EXCEED 140 ºC
Material 316 Stainless Steel
Dimensions (Body: HiTemp140-1) 1.6 in x 0.970 in dia. (40 mm x 24.6 mm dia.)
Dimensions (Body: HiTemp140-2,
HiTemp140-5.25, HiTemp140-7) 1.9 in x 0.970 in dia. (48 mm x 24.6 mm dia.)
Weight 4.2 oz (120 g)
Submersible Yes (IP68)
Approvals CE
Model Number Dimensions (Probe)
HiTemp140-1 1.1 in x 0.125 in dia. (0.188 in transitional diameter)
27 mm x 3.2 mm dia. (4.8 mm transitional diameter)
HiTemp140-2 2.0 in x 0.188 in dia. (51 mm x 4.8 mm dia.)
HiTemp140-2-TD 2.0 in x 0.125 in dia. (0.188 in transitional diameter)
51 mm x 3.2 mm dia. (4.8 mm transitional diameter)
HiTemp140-5.25 5.25 in x 0.188 in dia. (133 mm x 4.8 mm dia.)
HiTemp140-5.25-TD 5.25 in x 0.125 in dia. (0.188 in transitional diameter)
133 mm x 3.2 mm dia. (4.8 mm transitional diameter)
HiTemp140-7 7.0 in x 0.188 in dia. (178 mm x 4.8 mm dia.)
IFC400 (Sold Separately)
IFC406 (Sold Separately)
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1211035-00 REV 12 02.21.2017
Product Notes
The HiTemp140 is a rugged, high precision, temperature data logger that is built for use with
autoclaves and harsh environments. This stainless steel device is submersible, can withstand
temperatures up to 140 °C (284 °F) and has an accuracy of +/-0.1 °C (0.18 °F).
NOTE: BODY OF LOGGER CAN NOT EXCEED 140 °C
The HiTemp140 can store up to 32,700 readings, and features a rigid external probe capable
of measuring extended temperatures, up to 260 °C (500 °F). Custom probe lengths up to
7 inches are available. The device records date and time stamped readings, and has non-
volatile solid state memory that will retain data even if the battery becomes discharged. The
HiTemp140 can be used in both wet and dry applications up to 140 °C indefinitely.
Submergibility
The HiTemp140 is fully submersible and is rated IP68. It can be placed in environments with
up to 230 feet (70 m) of water.
O-Rings
O-ring maintenance is a key factor when properly caring for the HiTemp140. The O-rings
ensure a tight seal and prevent liquid from entering the inside of the device. Please refer to
the application note “O-Rings 101: Protecting Your Data”, found on the MadgeTech website,
for information on how to prevent O-ring failure.
Note: This product is rated for use up to 140 °C. Please heed the battery warning. The product will explode if exposed to
temperatures above 140 °C.
Installation Guide
Installing the Interface cable
- IFC400 or IFC406
Refer to the “Quick Start Guide” included in the package.
Installing the software
The Software can be downloaded from the MadgeTech website at the following link:
www.madgetech.com/software-download. Follow the instructions provided in the Installation
Wizard to install the MadgeTech Software.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the docking station.
- Connect the USB end of the interface cable into an open USB port on the computer.
- Place the data logger into the docking station.
- The data logger will automatically appear under Connected Devices within the software.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging application
and click “Start”. (“Quick Start” applies the most recent custom start options, “Batch Start”
is used for managing multiple loggers at once, “Real Time Start” stores the dataset as it records
while connected to the logger.)
Product User Guide
HiTemp140
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the docking station and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless user selectable
memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Place the logger into the docking station.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement Warning
When replacing the battery, it is important to insert the battery with positive polarity pointing
upward towards the probe. Failure to do so could result in product inoperability or potential
explosion if exposed to high temperatures.
Recalibration
The HiTemp140 standard calibration points are 20 °C and 140 °C.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 150 °C (302 °F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com

This manual suits for next models

7

Other MadgeTech Other manuals

MadgeTech PRHTemp101A User manual

MadgeTech

MadgeTech PRHTemp101A User manual

MadgeTech HiTemp140-M12 User manual

MadgeTech

MadgeTech HiTemp140-M12 User manual

MadgeTech UltraShock-5 Specification sheet

MadgeTech

MadgeTech UltraShock-5 Specification sheet

MadgeTech QuadTemp Specification sheet

MadgeTech

MadgeTech QuadTemp Specification sheet

MadgeTech TransiTempII-RH User manual

MadgeTech

MadgeTech TransiTempII-RH User manual

MadgeTech RHTemp101A User manual

MadgeTech

MadgeTech RHTemp101A User manual

MadgeTech TempRetrieverRH Specification sheet

MadgeTech

MadgeTech TempRetrieverRH Specification sheet

MadgeTech IFC300 User manual

MadgeTech

MadgeTech IFC300 User manual

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech Element CO2 Specification sheet

MadgeTech

MadgeTech Element CO2 Specification sheet

MadgeTech QuadRT User manual

MadgeTech

MadgeTech QuadRT User manual

MadgeTech TransiTemp-EC User manual

MadgeTech

MadgeTech TransiTemp-EC User manual

MadgeTech IFC200 User manual

MadgeTech

MadgeTech IFC200 User manual

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech DHS User manual

MadgeTech

MadgeTech DHS User manual

Popular Other manuals by other brands

Shinyei A01-16400 instruction manual

Shinyei

Shinyei A01-16400 instruction manual

HTC Vive Focus user guide

HTC

HTC Vive Focus user guide

Paradyne 9109 release note

Paradyne

Paradyne 9109 release note

Vetus ILTCONW Installation instructions and owner's manual

Vetus

Vetus ILTCONW Installation instructions and owner's manual

Alien ALR-9890 - RR Hardware setup guide

Alien

Alien ALR-9890 - RR Hardware setup guide

ASCOM ACCESS NODE brochure

ASCOM

ASCOM ACCESS NODE brochure

Eaton EAFR-101 user manual

Eaton

Eaton EAFR-101 user manual

Wynn's EW30001 Operation manual

Wynn's

Wynn's EW30001 Operation manual

Romy FIGURE user manual

Romy

Romy FIGURE user manual

turck BL IDENT installation manual

turck

turck BL IDENT installation manual

AMX AXC-232 Specifications

AMX

AMX AXC-232 Specifications

Skyetek SkyeReader 300 user guide

Skyetek

Skyetek SkyeReader 300 user guide

HydraMaster TITAN 425 Owner’s Guide and Maintenance Schedule

HydraMaster

HydraMaster TITAN 425 Owner’s Guide and Maintenance Schedule

PPE High Idle/Valet Switch installation guide

PPE

PPE High Idle/Valet Switch installation guide

Airaid 400-758 installation instructions

Airaid

Airaid 400-758 installation instructions

Autel EST201 manual

Autel

Autel EST201 manual

iLive ISP591B user guide

iLive

iLive ISP591B user guide

Tetra Cascade Globe operating instructions

Tetra

Tetra Cascade Globe operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.