manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Other
  8. •
  9. MadgeTech RTDTemp101A User manual

MadgeTech RTDTemp101A User manual

RTDTemp101A
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION AND SEVERE BURN HAZARD. DO NOT RECHARGE, DISASSEMBLE,
HEAT ABOVE 100 °C (212 °F), INCINERATE, CRUSH, OR EXPOSE CONTENTS TO WATER.
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1216035-00 REV 9 2015.07.01
RTDTemp101A
Temperature Data Logger with 10 Year Battery Life
Description RTDTemp101A
Temperature Sensor** External 100
Ω
RTD (Sold Separately)
Temperature Range 18 Ωto 400 Ω, –200 °C to +850 °C (-328 °F to +1562 °F)
(Probe Dependent)
Temperature Resolution 0.0001 Ω, 0.01 °C (0.018 °F) (Probe Dependent)
Calibrated Accuracy ±0.015 Ω, ±0.05 °C (±0.09 °F) (Probe Dependent)
Memory 1,340,000 readings software configurable memory wrap
666,000 readings in multiple start/stop mode
Wrap Around Yes
Reading Rate 1 reading every second up to 1 reading every 24 hours
LED Indicator Red & Green
Alarm Yes
Required Interface Package IFC200
Baud Rate 115,200
Battery Life
10 years typical at a 15 minute reading rate
Graph display of the device recording in a 25 °C environment.
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F),
0 %RH to 95 %RH non-condensing
Material ABS plastic
Dimensions 1.4 in x 2.2 in x 0.6 in (36 mm x 56 mm x 16 mm)
Weight 0.8 oz (24 g)
Approvals CE
Product User Guide
Product Notes
LEDs
- Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start
mode.
- Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to
indicate an alarm condition.
Password Protection
An optional password may be programmed into the device to restrict access to
configuration options. Data may be read out without the password
Multiple Start/Stop Mode Activation
- To start device: Press and hold the pushbutton for 5 seconds, the green LED will flash
during this time. The device has started logging.
- To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash
during this time. The device has stopped logging.
Alarm Settings
Programmable high and low limits; alarm is activated when temperature reaches or
exceeds set limits.
Wiring the Data Logger
Wiring Options
For 4-wire RTD probes, connect the four lead wires to your RTD
logger as shown in the figure.
For 3-wire RTD probes, short inputs 3 and 4 together, then connect
the lead wires to inputs 1, 2 and 3.
For 2-wire RTD probes, short inputs 3 and 4 together and inputs 1
and 2 together, then connect the RTD lead wires to inputs 2 and 3.
Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
100 Ω, 2 or 4 wire RTD probes are recommended for the most
accurate performance. Most 100 Ω, 3 wire RTD probes will work,
but MadgeTech cannot guarantee the accuracy. To determine
whether or not the 3-wire RTD probe will work, the resistance
between the two same colored wires should be less than 1 Ω.
(Note: Please contact the manufacturer of the RTD probe for questions on the resistance)
Installation Guide
Installing the Interface cable
- IFC200:
Insert the device into a USB port. The drivers will install automatically.
Installing the software
Software can also be downloaded from the MadgeTech website at the following link: www.
madgetech.com/software-download. Double click the zipped download file and follow the
steps to finsh downloading
RTDTemp101A Product User Guide
Device Operation
Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver
LTC-7PN battery
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Recalibration
Standard calibration is two points at 50 Ωand 150 Ωand is verified at 100 Ω.
Additional Services:
Custom calibration and verification point options available, please call for pricing.
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.
KEY
1 - Ref +
2 - Measurement (-) Input
3 - Measurement (+) Input
4 - Excitation Current Out (+)
1 - Black or Short to 2
2 - Black
3 - Red
4 - Red or Short to 3
1
2
3
4
1
2
3
4

Other MadgeTech Other manuals

MadgeTech TempRetrieverRH Specification sheet

MadgeTech

MadgeTech TempRetrieverRH Specification sheet

MadgeTech RHTemp101A User manual

MadgeTech

MadgeTech RHTemp101A User manual

MadgeTech UltraShock-5 Specification sheet

MadgeTech

MadgeTech UltraShock-5 Specification sheet

MadgeTech TransiTempII-RH User manual

MadgeTech

MadgeTech TransiTempII-RH User manual

MadgeTech QuadTemp Specification sheet

MadgeTech

MadgeTech QuadTemp Specification sheet

MadgeTech IFC300 User manual

MadgeTech

MadgeTech IFC300 User manual

MadgeTech QuadRT User manual

MadgeTech

MadgeTech QuadRT User manual

MadgeTech Element CO2 Specification sheet

MadgeTech

MadgeTech Element CO2 Specification sheet

MadgeTech TransiTemp-EC User manual

MadgeTech

MadgeTech TransiTemp-EC User manual

MadgeTech HiTemp140-2 Specification sheet

MadgeTech

MadgeTech HiTemp140-2 Specification sheet

MadgeTech PRHTemp101A User manual

MadgeTech

MadgeTech PRHTemp101A User manual

MadgeTech DHS User manual

MadgeTech

MadgeTech DHS User manual

MadgeTech HiTemp140-M12 User manual

MadgeTech

MadgeTech HiTemp140-M12 User manual

MadgeTech IFC200 User manual

MadgeTech

MadgeTech IFC200 User manual

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

Popular Other manuals by other brands

Dreamline PRIME 31x31 installation instructions

Dreamline

Dreamline PRIME 31x31 installation instructions

808audio CANZ SP880 quick start guide

808audio

808audio CANZ SP880 quick start guide

I.SOUND WALL Product features

I.SOUND

I.SOUND WALL Product features

Reelcraft Industries, Inc. SD13050 OLP118 operating instructions

Reelcraft Industries, Inc.

Reelcraft Industries, Inc. SD13050 OLP118 operating instructions

Pro DVX F101 HD user manual

Pro DVX

Pro DVX F101 HD user manual

Keyautomation ALT3KF Series Instructions and warnings for installation and use

Keyautomation

Keyautomation ALT3KF Series Instructions and warnings for installation and use

DAVIS Alarm Output Module brochure

DAVIS

DAVIS Alarm Output Module brochure

Basler BE1-67 instructions

Basler

Basler BE1-67 instructions

Superwinch EP/EPi6.0 owner's manual

Superwinch

Superwinch EP/EPi6.0 owner's manual

AKO AKO-575744 quick guide

AKO

AKO AKO-575744 quick guide

IBM HS21 BLADECENTER - 5160 FOR SPEC CPU2000 specification

IBM

IBM HS21 BLADECENTER - 5160 FOR SPEC CPU2000 specification

Magic Leap One Safety Guide & Regulatory Information

Magic Leap

Magic Leap One Safety Guide & Regulatory Information

EasyFire EF3801B-AL Installation & operating instructions

EasyFire

EasyFire EF3801B-AL Installation & operating instructions

Performance Tool M613 owner's manual

Performance Tool

Performance Tool M613 owner's manual

Siemens SIMATIC Ident 6GT2690-0AK00 Compact operating instructions

Siemens

Siemens SIMATIC Ident 6GT2690-0AK00 Compact operating instructions

Edaphic Scientific ESSAN-01 user manual

Edaphic Scientific

Edaphic Scientific ESSAN-01 user manual

Discus Potters Wheels user manual

Discus

Discus Potters Wheels user manual

Autel AutoLink AL609P Quick reference guide

Autel

Autel AutoLink AL609P Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.